36
505039
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
24. ACCUMULATOR (Electromechanical
Metered Models)
a. Unlock control panel. See Figure 8A.
b. Pull top of control panel away from control
cabinet and lift up. See Figure 8B.
c. Remove control panel from control cabinet. See
Figure 8C.
d. Disconnect all wires to components. See
e. Remove ground clip holding ground wire to
control panel. See Figure 9.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
f. Reach in through control panel opening and
remove screws holding accumulator and
mounting bracket to the control cabinet. See
Figure 20.
g. Disconnect wires from accumulator at the
connectors.
NOTE: Refer to appropriate wiring diagram when
rewiring the timer.
h. Remove two screws holding accumulator to
mounting bracket. See Figure 20.
i. Models with Counter (Figure 11)
(1.) Disconnect wire from terminal on
accumulator switch "c."
(2.) Cut the other wire at the butt splice
connector.
(3.) Cut harness strap holding wires to bracket.
NOTE: Harness strap must be replaced during
reinstallation.
(4.) The counter(s) are mounted inside the
control cabinet with two-sided tape.
NOTE: When installing a new counter, remove the
protective backing from the tape located on the
underside of new counter. Firmly press the new
counter in place. Tape on counter will reach full
adhesion in approximately twenty-four hours.
Figure 20
ACCUMULATOR
ATTACHING
SCREWS
D187SE3A