Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
16. SERVICE DOOR, ACCUMULATOR AND
TIMING MOTOR ASSEMBLY (Metered
Models)
Refer to Figure 7
a. Insert key in service door lock on top of meter
case and turn key one quarter turn
counterclockwise.
b. Lift rear end of service door approximately 45°
off meter case to disengage notched tabs on
front end from rib inside of meter case.
NOTE: When reinstalling service door and
accumulator, front end of door must be inserted at
about 45° angle in order to engage notched tabs
with internal rib at top of meter case.
c. Disconnect accumulator wires at connectors.
NOTE: Refer to wiring diagram when reconnecting
wires.
d. Remove hex head ground screw holding green
ground wire to accumulator mounting bracket.
e. Remove two Phillips head screws and
lockwashers holding accumulator to mounting
bracket.
Figure 9
To Test Accumulator and Timing Motor
(Metered Models)
Refer to Figure 9
1. Disconnect electrical service to dryer.
2. Remove service door, accumulator and timing
motor assembly.
3. Remove wires from one side of switches A, B
and C.
NOTE: Refer to appropriate wiring diagram
when rewiring switches.
4. Advance ratchet to put time on the accumulator.
5. Set test meter to read ohms and apply meter
leads on terminals of each switch in turn. You
should get “zero” reading on each switch.
Timing Motor
6. Apply live power to timing motor leads (in
connectors), timing motor should advance
timing cam.