Entering the Manual Mode

For programming, testing, and retrieving information 
from NetMaster, it is often necessary to enter the 
Manual Mode by following the four simple steps below.

How to Enter the Manual Mode

1. Be sure the washer-extractor is in the Ready Mode 

before continuing to step 2. Refer to Figure 1. If 
the washer-extractor is in an active cycle, rapid 
advance through the cycle. Refer to Rapid 
Advance Feature 
section of the Basic 
Programming Guide. If coins have been entered, 
refer to Clear Vend Feature section of the Basic 
Programming Guide.

Figure 1 

2. Open the access panel. Refer to Opening the 

Access Panel section of the Basic Programming 
Guide.

3. While pressing and holding the NORMAL 

keypad with one hand, press the HOT keypad 
with the other hand.

4. The VFD display will show “

rAPd

”. Refer to 

Figure 2.

Figure 2 

5. Press the DELICATES (+) or the COLD (-) 

keypad to scroll through the options until the 
desired option appears in the VFD.

6. Press the START (enter) keypad.

For additional information on the Manual Mode, refer 
to Entering Manual Mode section of the Basic 
Programming Guide.

C854I

B30R

Содержание NetMaster HC18NC2

Страница 1: ...her Extractor Cabinet Hard Mount Enhanced Programming Guide Refer to Page 5 for Model Numbers C872I Part No F232152R1 September 2004 Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine ...

Страница 2: ......

Страница 3: ...s are factors which cannot be built into these washer extractors These factors MUST BE supplied by the person s installing maintaining or operating the washer extractor Always contact the distributor service agent or the manufacturer about any problems or conditions you do not understand WARNING Failure to install maintain and or operate this machine according to the manufacturer s instructions ma...

Страница 4: ...2 800767 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...

Страница 5: ...Normal Spin Extract Speed 049 33 14 Normal Extracts On Off 050 34 15 Permanent Press PreWash 2 Fill Tumble Time 052 37 16 Permanent Press Rinse Extra Fill Tumble Time 055 38 17 Permanent Press Spin Extract Speed 058 39 18 Permanent Press Extracts On Off 059 40 19 Delicates PreWash 1 Fill Tumble Time 060 43 20 Delicates PreWash 2 Fill Tumble Time 061 44 21 Delicates Rinse Extra Fill Tumble Time 064...

Страница 6: ...mble Drain 102 104 52 Rinse 1 Drain Tumble Drain 103 106 53 Rinse 1 Extract Drain 104 108 54 Rinse Extra Fill Tumble Drain 105 110 55 Rinse Extra Drain Tumble Drain 106 112 56 Rinse Extra Extract Drain 107 114 57 Rinse Final Fill Tumble Drain 108 116 58 Rinse Final Drain Tumble Drain 109 118 59 Rinse Final Extract Drain 110 120 60 Spin Extract Drain 111 122 61 Spin Shakeout Drain 112 124 62 Water ...

Страница 7: ...NX2 HC25NX2 NC18NP2 NC80NCV SC40NC2 HC27NC2 NC18NR2 NC80NPV SC40NR2 HC27NR2 NC18NX2 NC80NRV SC40NX2 HC27NX2 NC25NC2 NC80NXV SC50NC2 HC30NC2 NC25NP2 SC18NC2 SC50NR2 HC35NC2 NC25NR2 SC18NR2 SC50NX2 HC35NR2 NC25NX2 SC18NX2 SC60NC2 HC35NX2 NC27NC2 SC20NC2 SC60NCF HC40NC2 NC27NP2 SC20NR2 SC60NR2 HC40NR2 NC27NR2 SC20NX2 SC60NRF HC40NX2 NC27NX2 SC25NC2 SC60NX2 HC50NC2 NC35NC2 SC25NR2 SC80NCV HC50NR2 NC35...

Страница 8: ...F232152 6 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...

Страница 9: ... Feature section of the Basic Programming Guide If coins have been entered refer to Clear Vend Feature section of the Basic Programming Guide Figure 1 2 Open the access panel Refer to Opening the Access Panel section of the Basic Programming Guide 3 While pressing and holding the NORMAL keypad with one hand press the HOT keypad with the other hand 4 The VFD display will show rAPd Refer to Figure 2...

Страница 10: ...F232152 8 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...

Страница 11: ...Card Reader or the Network Refer to this section when programming NetMaster This section offers a detailed description of options available to program Additional options can be found in the Basic Programming Guide Each description includes instructions on when and why the option might be used and more importantly how to program the option For more advanced users a quick reference list of the optio...

Страница 12: ...d 077 Special Wash Extracts On Off 078 PreWash 1 PreWash 2 Rinses Water Temperature 079 Fill Tumbles Water Levels 1 080 Fill Tumbles Water Levels 2 082 Control Configuration Data 2 083 Control Configuration Data 3 084 Hot Water Temperature 085 Warm Water Temperature 086 Cold Water Temperature 087 PreWash 1 Fill Tumble Dispenser 088 PreWash 2 Fill Tumble Dispenser 089 Wash Fill Tumble Dispenser 090...

Страница 13: ...ar in the VFD Figure 3 3 Press the DELICATES or the COLD keypad to scroll through the programmable options until 008 appears in the VFD Refer to Figure 4 Figure 4 4 When 008 appears in the VFD press the START enter keypad There are five digits in the Site Code 1 Hot Regular Wash Vend Price The fifth digit will appear in the VFD and will flash one second on one second off Refer to Figure 5 Figure 5...

Страница 14: ...TART enter keypad to enter the value of the digit and advance to the next digit 8 Press the START enter keypad with the last active digit The next option 009 will appear in the VFD NOTE To program 009 Site Code 1 Warm Regular Wash Vend Price refer to option 9 To program other options refer to the appropriate section How to Exit Programming Feature 1 Be sure the control shows a programmable option ...

Страница 15: ...r in the VFD Figure 8 3 Press the DELICATES or the COLD keypad to scroll through the programmable options until 009 appears in the VFD Refer to Figure 9 Figure 9 4 When 009 appears in the VFD press the START enter keypad There are five digits in the Site Code 1 Warm Regular Wash Vend Price The fifth digit will appear in the VFD and will flash one second on one second off Refer to Figure 10 Figure ...

Страница 16: ...START enter keypad to enter the value of the digit and advance to the next digit 8 Press the START enter keypad with the last active digit The next option 010 will appear in the VFD NOTE To program 010 Site Code 1 Cold Regular Wash Vend Price refer to option 10 To program other options refer to the appropriate section How to Exit Programming Feature 1 Be sure the control shows a programmable optio...

Страница 17: ... in the VFD Figure 13 3 Press the DELICATES or the COLD keypad to scroll through the programmable options until 010 appears in the VFD Refer to Figure 14 Figure 14 4 When 010 appears in the VFD press the START enter keypad There are five digits in the Site Code 1 Cold Regular Wash Vend Price The fifth digit will appear in the VFD and will flash one second on one second off Refer to Figure 15 Figur...

Страница 18: ...START enter keypad to enter the value of the digit and advance to the next digit 8 Press the START enter keypad with the last active digit The next option 011 will appear in the VFD NOTE To program 011 Site Code 1 Hot Special Wash Vend Price refer to option 11 To program other options refer to the appropriate section How to Exit Programming Feature 1 Be sure the control shows a programmable option...

Страница 19: ...in the VFD Figure 18 3 Press the DELICATES or the COLD keypad to scroll through the programmable options until 011 appears in the VFD Refer to Figure 19 Figure 19 4 When 011 appears in the VFD press the START enter keypad There are five digits in the Site Code 1 Hot Special Wash Vend Price The fifth digit will appear in the VFD and will flash one second on one second off Refer to Figure 20 Figure ...

Страница 20: ...START enter keypad to enter the value of the digit and advance to the next digit 8 Press the START enter keypad with the last active digit The next option 012 will appear in the VFD NOTE To program 012 Site Code 1 Warm Special Wash Vend Price refer to option 12 To program other options refer to the appropriate section How to Exit Programming Feature 1 Be sure the control shows a programmable optio...

Страница 21: ... in the VFD Figure 23 3 Press the DELICATES or the COLD keypad to scroll through the programmable options until 012 appears in the VFD Refer to Figure 24 Figure 24 4 When 012 appears in the VFD press the START enter keypad There are five digits in the Site Code 1 Warm Special Wash Vend Price The fifth digit will appear in the VFD and will flash one second on one second off Refer to Figure 25 Figur...

Страница 22: ...START enter keypad to enter the value of the digit and advance to the next digit 8 Press the START enter keypad with the last active digit The next option 013 will appear in the VFD NOTE To program 013 Site Code 1 Cold Special Wash Vend Price refer to option 13 To program other options refer to the appropriate section How to Exit Programming Feature 1 Be sure the control shows a programmable optio...

Страница 23: ... in the VFD Figure 28 3 Press the DELICATES or the COLD keypad to scroll through the programmable options until 013 appears in the VFD Refer to Figure 29 Figure 29 4 When 013 appears in the VFD press the START enter keypad There are five digits in the Site Code 1 Cold Special Wash Vend Price The fifth digit will appear in the VFD and will flash one second on one second off Refer to Figure 30 Figur...

Страница 24: ...and the START enter keypad to enter the value of the digit and advance to the next digit 8 Press the START enter keypad with the last active digit The next option 014 will appear in the VFD NOTE To program 014 Special Cycle Vend Price refer to option 14 To program other options refer to the appropriate section How to Exit Programming Feature 1 Be sure the control shows a programmable option not a ...

Страница 25: ...e VFD Press the START enter keypad and 001 will appear in the VFD Figure 33 3 Press the DELICATES or the COLD keypad to scroll through the programmable options until 014 appears in the VFD Refer to Figure 34 Figure 34 4 When 014 appears in the VFD press the START enter keypad There are five digits in the Special Cycle Vend Price The fifth digit will appear in the VFD and will flash one second on o...

Страница 26: ...to enter the value of the digit and advance to the next digit 8 Press the START enter keypad with the last active digit The next option 015 will appear in the VFD NOTE To program 015 Special Vend A Days Enable refer to option 15 in Programming NetMaster in the Basic Programming Guide To program other options refer to the appropriate section How to Exit Programming Feature 1 Be sure the control sho...

Страница 27: ...ypad until PrOg appears in the VFD Press the START enter keypad and 001 will appear in the VFD Figure 38 3 Press the DELICATES or the COLD keypad to scroll through the programmable options until 022 appears in the VFD Refer to Figure 39 Figure 39 4 When 022 appears in the VFD press the START enter keypad There are five digits in the Special Vend A Site Code 1 The fifth digit will appear in the VFD...

Страница 28: ...he value of the digit and advance to the next digit 8 Press the START enter keypad with the last active digit The next option 023 will appear in the VFD NOTE To program 023 Special Vend A Regular Hot Wash Vend Price refer to option 23 in Programming NetMaster in the Basic Programming Guide To program other options refer to the appropriate section How to Exit Programming Feature 1 Be sure the contr...

Страница 29: ... appear in the VFD Figure 43 3 Press the DELICATES or the COLD keypad to scroll through the programmable options until 032 appears in the VFD Refer to Figure 44 Figure 44 4 When 032 appears in the VFD press the START enter keypad There are five digits in the Start Pulse Value The fifth digit will appear in the VFD and will flash one second on and one second off Refer to Figure 45 Figure 45 5 Press...

Страница 30: ... enter the value of the digit and advance to the next digit 8 Press the START enter keypad with the last active digit The next option 033 will appear in the VFD NOTE To program 033 Default Cycle Temperature refer to option 33 in Programming NetMaster in the Basic Programming Guide To program other options refer to the appropriate section How to Exit Programming Feature 1 Be sure the control shows ...

Страница 31: ... START enter keypad A number will appear in the VFD This number corresponds to the current Power Fail Reset setting 5 Press the DELICATES or the COLD keypad to increase or decrease the current number to the desired number selected from Table 1 Refer to Figure 50 Figure 50 6 Press the START enter keypad when the correct number appears in the VFD The next option 035 will appear in the VFD NOTE To pr...

Страница 32: ...entered the current cycle status will be saved for up to six years When power is restored the cycle will begin where it was interrupted If 133 is entered the current cycle will be saved for up to five minutes If power is not restored within five minutes the control will erase the cycle status The minimum power failure time is five minutes The maximum power fail reset time is 127 minutes 034 Power ...

Страница 33: ...the DELICATES or the COLD keypad to increase or decrease the current number of minutes displayed in the VFD to the desired number of minutes Refer to Figure 53 NOTE The Normal PreWash 2 Fill Tumble Time can be set from zero 0 to 15 minutes Figure 53 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 044 will appear in the VFD NOTE To program 044 No...

Страница 34: ...ELICATES or the COLD keypad to increase or decrease the current number of minutes displayed in the VFD to the desired number of minutes Refer to Figure 56 NOTE The Normal Rinse Extra Fill Tumble Time can be set from zero 0 to 15 minutes Figure 56 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 047 will appear in the VFD NOTE To program 047 Norma...

Страница 35: ...lue of 0 High Speed Value of 1 Very High Speed NOTE Very High Speed is available on Variable Frequency Drive models NRV only 5 Press the DELICATES or the COLD keypad to increase or decrease the current extraction speed displayed in the VFD to the desired extraction speed Refer to Figure 59 Figure 59 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next optio...

Страница 36: ... DELICATES or the COLD keypad to increase or decrease the current extract value displayed in the VFD to the desired extract value as found in Table 2 Refer to Figure 62 Figure 62 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 051 will appear in the VFD NOTE To program 051 Permanent Press PreWash 1 Fill Tumble Time refer to option 51 in Programm...

Страница 37: ... ON OFF OFF OFF OFF 003 ON ON OFF OFF OFF OFF 004 OFF OFF ON OFF OFF OFF 005 ON OFF ON OFF OFF OFF 006 OFF ON ON OFF OFF OFF 007 ON ON ON OFF OFF OFF 008 OFF OFF OFF ON OFF OFF 009 ON OFF OFF ON OFF OFF 010 OFF ON OFF ON OFF OFF 011 ON ON OFF ON OFF OFF 012 OFF OFF ON ON OFF OFF 013 ON OFF ON ON OFF OFF 014 OFF ON ON ON OFF OFF 015 ON ON ON ON OFF OFF 016 OFF OFF OFF OFF ON OFF 017 ON OFF OFF OFF ...

Страница 38: ... OFF ON 041 ON OFF OFF ON OFF ON 042 OFF ON OFF ON OFF ON 043 ON ON OFF ON OFF ON 044 OFF OFF ON ON OFF ON 045 ON OFF ON ON OFF ON 046 OFF ON ON ON OFF ON 047 ON ON ON ON OFF ON 048 OFF OFF OFF OFF ON ON 049 ON OFF OFF OFF ON ON 050 OFF ON OFF OFF ON ON 051 ON ON OFF OFF ON ON 052 OFF OFF ON OFF ON ON 053 ON OFF ON OFF ON ON 054 OFF ON ON OFF ON ON 055 ON ON ON OFF ON ON 056 OFF OFF OFF ON ON ON 0...

Страница 39: ...s the DELICATES or the COLD keypad to increase or decrease the current number of minutes displayed in the VFD to the desired number of minutes Refer to Figure 65 NOTE The Permanent Press PreWash 2 Fill Tumble Time can be set from zero 0 to 15 minutes Figure 65 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 053 will appear in the VFD NOTE To pro...

Страница 40: ... the DELICATES or the COLD keypad to increase or decrease the current number of minutes displayed in the VFD to the desired number of minutes Refer to Figure 68 NOTE The Permanent Press Rinse Extra Fill Tumble Time can be set from zero 0 to 15 minutes Figure 68 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 056 will appear in the VFD NOTE To pr...

Страница 41: ... in the VFD Value of 0 High Speed Value of 1 Very High Speed NOTE Very High Speed is available on Variable Frequency Drive models NRV only 5 Press the DELICATES or the COLD keypad to increase or decrease the current extraction speed displayed in the VFD to the desired extraction speed Refer to Figure 71 Figure 71 6 Press the START enter keypad when the correct number of minutes appears in the VFD ...

Страница 42: ...nt Press Extracts On Off will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current extract value displayed in the VFD to the desired extract value Refer to Figure 74 Figure 74 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 060 will appear in the VFD NOTE To program 060 Delicates PreWash 1 Fill Tumble Ti...

Страница 43: ... ON OFF OFF OFF OFF 003 ON ON OFF OFF OFF OFF 004 OFF OFF ON OFF OFF OFF 005 ON OFF ON OFF OFF OFF 006 OFF ON ON OFF OFF OFF 007 ON ON ON OFF OFF OFF 008 OFF OFF OFF ON OFF OFF 009 ON OFF OFF ON OFF OFF 010 OFF ON OFF ON OFF OFF 011 ON ON OFF ON OFF OFF 012 OFF OFF ON ON OFF OFF 013 ON OFF ON ON OFF OFF 014 OFF ON ON ON OFF OFF 015 ON ON ON ON OFF OFF 016 OFF OFF OFF OFF ON OFF 017 ON OFF OFF OFF ...

Страница 44: ... OFF ON 041 ON OFF OFF ON OFF ON 042 OFF ON OFF ON OFF ON 043 ON ON OFF ON OFF ON 044 OFF OFF ON ON OFF ON 045 ON OFF ON ON OFF ON 046 OFF ON ON ON OFF ON 047 ON ON ON ON OFF ON 048 OFF OFF OFF OFF ON ON 049 ON OFF OFF OFF ON ON 050 OFF ON OFF OFF ON ON 051 ON ON OFF OFF ON ON 052 OFF OFF ON OFF ON ON 053 ON OFF ON OFF ON ON 054 OFF ON ON OFF ON ON 055 ON ON ON OFF ON ON 056 OFF OFF OFF ON ON ON 0...

Страница 45: ...r in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current number of minutes displayed in the VFD to the desired number of minutes Refer to Figure 77 NOTE The Delicates PreWash 1 Fill Tumble Time can be set from zero 0 to 15 minutes Figure 77 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 061 will appear in the VF...

Страница 46: ...DELICATES or the COLD keypad to increase or decrease the current number of minutes displayed in the VFD to the desired number of minutes Refer to Figure 80 NOTE The Delicates PreWash 2 Fill Tumble Time can be set from zero 0 to 15 minutes Figure 80 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 062 will appear in the VFD NOTE To program 062 Del...

Страница 47: ...ELICATES or the COLD keypad to increase or decrease the current number of minutes displayed in the VFD to the desired number of minutes Refer to Figure 83 NOTE The Delicates Rinse Extra Fill Tumble Time can be set from zero 0 to 15 minutes Figure 83 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 065 will appear in the VFD NOTE To program 065 De...

Страница 48: ... Value of 0 High Speed Value of 1 Very High Speed NOTE Very High Speed is available on Variable Frequency Drive models NRV only 5 Press the DELICATES or the COLD keypad to increase or decrease the current extraction speed displayed in the VFD to the desired extraction speed Refer to Figure 86 Figure 86 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next op...

Страница 49: ... VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current extract value displayed in the VFD to the desired extract value Refer to Figure 89 Figure 89 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 069 will appear in the VFD NOTE To program 069 Special Wash PreWash 1 Fill Tumble Time refer to option 69 in Programming Net...

Страница 50: ... ON OFF OFF OFF OFF 003 ON ON OFF OFF OFF OFF 004 OFF OFF ON OFF OFF OFF 005 ON OFF ON OFF OFF OFF 006 OFF ON ON OFF OFF OFF 007 ON ON ON OFF OFF OFF 008 OFF OFF OFF ON OFF OFF 009 ON OFF OFF ON OFF OFF 010 OFF ON OFF ON OFF OFF 011 ON ON OFF ON OFF OFF 012 OFF OFF ON ON OFF OFF 013 ON OFF ON ON OFF OFF 014 OFF ON ON ON OFF OFF 015 ON ON ON ON OFF OFF 016 OFF OFF OFF OFF ON OFF 017 ON OFF OFF OFF ...

Страница 51: ... OFF ON 041 ON OFF OFF ON OFF ON 042 OFF ON OFF ON OFF ON 043 ON ON OFF ON OFF ON 044 OFF OFF ON ON OFF ON 045 ON OFF ON ON OFF ON 046 OFF ON ON ON OFF ON 047 ON ON ON ON OFF ON 048 OFF OFF OFF OFF ON ON 049 ON OFF OFF OFF ON ON 050 OFF ON OFF OFF ON ON 051 ON ON OFF OFF ON ON 052 OFF OFF ON OFF ON ON 053 ON OFF ON OFF ON ON 054 OFF ON ON OFF ON ON 055 ON ON ON OFF ON ON 056 OFF OFF OFF ON ON ON 0...

Страница 52: ...ess the DELICATES or the COLD keypad to increase or decrease the current number of minutes displayed in the VFD to the desired number of minutes Refer to Figure 92 NOTE The Special Wash PreWash 2 Fill Tumble Time can be set from zero 0 to 15 minutes Figure 92 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 071 will appear in the VFD NOTE To prog...

Страница 53: ...he DELICATES or the COLD keypad to increase or decrease the current number of minutes displayed in the VFD to the desired number of minutes Refer to Figure 95 NOTE The Special Wash Rinse Extra Fill Tumble Time can be set from zero 0 to 15 minutes Figure 95 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 074 will appear in the VFD NOTE To program...

Страница 54: ... VFD Value of 0 High Speed Value of 1 Very High Speed NOTE Very High Speed is available on Variable Frequency Drive models NRV only 5 Press the DELICATES or the COLD keypad to increase or decrease the current extraction speed displayed in the VFD to the desired extraction speed Refer to Figure 98 Figure 98 6 Press the START enter keypad when the correct number of minutes appears in the VFD The nex...

Страница 55: ...racts On Off will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current extract value displayed in the VFD to the desired extract value Refer to Figure 101 Figure 101 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 078 will appear in the VFD NOTE To program 078 PreWash 1 PreWash 2 Rinses Water Temperature...

Страница 56: ... ON OFF OFF OFF OFF 003 ON ON OFF OFF OFF OFF 004 OFF OFF ON OFF OFF OFF 005 ON OFF ON OFF OFF OFF 006 OFF ON ON OFF OFF OFF 007 ON ON ON OFF OFF OFF 008 OFF OFF OFF ON OFF OFF 009 ON OFF OFF ON OFF OFF 010 OFF ON OFF ON OFF OFF 011 ON ON OFF ON OFF OFF 012 OFF OFF ON ON OFF OFF 013 ON OFF ON ON OFF OFF 014 OFF ON ON ON OFF OFF 015 ON ON ON ON OFF OFF 016 OFF OFF OFF OFF ON OFF 017 ON OFF OFF OFF ...

Страница 57: ... OFF ON 041 ON OFF OFF ON OFF ON 042 OFF ON OFF ON OFF ON 043 ON ON OFF ON OFF ON 044 OFF OFF ON ON OFF ON 045 ON OFF ON ON OFF ON 046 OFF ON ON ON OFF ON 047 ON ON ON ON OFF ON 048 OFF OFF OFF OFF ON ON 049 ON OFF OFF OFF ON ON 050 OFF ON OFF OFF ON ON 051 ON ON OFF OFF ON ON 052 OFF OFF ON OFF ON ON 053 ON OFF ON OFF ON ON 054 OFF ON ON OFF ON ON 055 ON ON ON OFF ON ON 056 OFF OFF OFF ON ON ON 0...

Страница 58: ...responds to the current water temperature value for PreWash 1 PreWash 2 Initial Rinse Extra Rinse and Final Rinse 5 Press the DELICATES or the COLD keypad to increase or decrease the current value to the desired value selected from Table 6 on the following page Refer to Figure 104 Figure 104 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 079 wi...

Страница 59: ...D HOT WARM 008 COLD COLD WARM WARM COLD 009 COLD COLD WARM WARM WARM 010 COLD COLD WARM HOT COLD 011 COLD COLD WARM HOT WARM 016 COLD WARM COLD WARM COLD 017 COLD WARM COLD WARM WARM 018 COLD WARM COLD HOT COLD 019 COLD WARM COLD HOT WARM 024 COLD WARM WARM WARM COLD 025 COLD WARM WARM WARM WARM 026 COLD WARM WARM HOT COLD 027 COLD COLD WARM HOT WARM 032 WARM COLD COLD WARM COLD 033 WARM COLD COLD...

Страница 60: ...sh 1 PreWash 2 and Wash water levels during tumble and fill of all cycles 5 Press the DELICATES or the COLD keypad to increase or decrease the current water level value to the desired water level value selected from Table 7 on the following page Refer to Figure 107 Figure 107 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 080 will appear in the...

Страница 61: ...umns Option columns state whether an action is LOW MEDIUM or HIGH Water Level Value PreWash 1 PreWash 2 Wash 000 LOW LOW LOW 001 MED LOW LOW 002 HIGH LOW LOW 004 LOW MED LOW 005 MED MED LOW 006 HIGH MED LOW 008 LOW HIGH LOW 009 MED HIGH LOW 010 HIGH HIGH LOW 016 LOW LOW MED 017 MED LOW MED 018 HIGH LOW MED 020 LOW MED MED 021 MED MED MED 022 HIGH MED MED 024 LOW HIGH MED 025 MED HIGH MED 026 HIGH ...

Страница 62: ... water levels during tumble and fill of all cycles 5 Press the DELICATES or the COLD keypad to increase or decrease the current water level value to the desired water level value selected from Table 8 on the following page Refer to Figure 110 Figure 110 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 081 will appear in the VFD NOTE To program 08...

Страница 63: ...tion columns state whether an action is LOW MEDIUM or HIGH Water Level Value Initial Rinse Extra Rinse Final Rinse 000 LOW LOW LOW 001 MED LOW LOW 002 HIGH LOW LOW 004 LOW MED LOW 005 MED MED LOW 006 HIGH MED LOW 008 LOW HIGH LOW 009 MED HIGH LOW 010 HIGH HIGH LOW 016 LOW LOW MED 017 MED LOW MED 018 HIGH LOW MED 020 LOW MED MED 021 MED MED MED 022 HIGH MED MED 024 LOW HIGH MED 025 MED HIGH MED 026...

Страница 64: ...mber corresponds to the current Control Configuration Data 2 Value 5 Press the DELICATES or the COLD keypad to increase or decrease the current number to the desired number selected from Table 9 Refer to Figure 113 Figure 113 6 Press the START enter keypad when the correct number appears in the VFD The next option 083 will appear in the VFD NOTE To program 083 Control Configuration Data 3 refer to...

Страница 65: ... Water Temperature Regulation Programs electronic control to regulate if equipped hot water temperature Refer to option 84 to program hot water temperature Default ON 3 Warm Water Temperature Regulation Programs electronic control to regulate if equipped warm water temperature Refer to option 85 to program warm water temperature Default OFF 4 Cold Water Temperature Regulation Programs electronic c...

Страница 66: ...006 WASH ON OFF OFF C OFF 007 WASH ON OFF OFF C ON 008 WASH OFF ON OFF F OFF 009 WASH OFF ON OFF F ON 010 WASH OFF ON OFF C OFF 011 WASH OFF ON OFF C ON 012 WASH ON ON OFF F OFF 013 WASH ON ON OFF F ON 014 WASH ON ON OFF C OFF 015 WASH ON ON OFF C ON 016 WASH OFF OFF ON F OFF 017 WASH OFF OFF ON F ON 018 WASH OFF OFF ON C OFF 019 WASH OFF OFF ON C ON 020 WASH ON OFF ON F OFF 021 WASH ON OFF ON F O...

Страница 67: ...ON OFF F OFF 073 RINSE OFF ON OFF F ON 074 RINSE OFF ON OFF C OFF 075 RINSE OFF ON OFF C ON 076 RINSE ON ON OFF F OFF 077 RINSE ON ON OFF F ON 078 RINSE ON ON OFF C OFF 079 RINSE ON ON OFF C ON 080 RINSE OFF OFF ON F OFF 081 RINSE OFF OFF ON F ON 082 RINSE OFF OFF ON C OFF 083 RINSE OFF OFF ON C ON 084 RINSE ON OFF ON F OFF 085 RINSE ON OFF ON F ON 086 RINSE ON OFF ON C OFF 087 RINSE ON OFF ON C O...

Страница 68: ... number corresponds to the current Control Configuration Data 3 Value 5 Press the DELICATES or the COLD keypad to increase or decrease the current number to the desired number selected from Table 10 Refer to Figure 116 Figure 116 6 Press the START enter keypad when the correct number appears in the VFD The next option 084 will appear in the VFD NOTE To program 084 Hot Water Temperature refer to op...

Страница 69: ...d Diagnostics Cool Down and to change the Available Output Mode NOTE Cool Down is for specially equipped models only Config 3 Value Cool Down RADV DIAG Access Available 0 Disabled OFF Ready Mode 1 Disabled OFF Until Start Mode 2 Disabled ON Ready Mode 3 Disabled ON Until Start Mode 4 Enabled OFF Ready Mode 5 Enabled OFF Until Start Mode 6 Enabled ON Ready Mode 7 Enabled ON Until Start Mode Table 1...

Страница 70: ...ecrease the current Hot Water Temperature value to the desired Hot Water Temperature value selected from Table 11 on the following page Refer to Figure 119 NOTE Hot Water Temperature is selectable between 60 and 190 Fahrenheit 16 and 87 Celsius Default temperature value is 17 120 F NOTE Refer to option 82 to select Celsius or Fahrenheit display Figure 119 6 Press the START enter keypad when the co...

Страница 71: ...ture value number to be entered into electronic control Temperature value is followed by two option columns Option columns state the temperature of the water Temperature Value Fahrenheit F Celsius C 5 60 16 6 65 19 7 70 22 8 75 24 9 80 27 10 85 30 11 90 33 12 95 35 13 100 38 14 105 41 15 110 44 16 115 46 17 120 49 18 125 52 19 130 54 20 135 57 21 140 60 22 145 63 23 150 65 24 155 68 25 160 71 26 1...

Страница 72: ...decrease the current Warm Water Temperature value to the desired Warm Water Temperature value selected from Table 12 on the following page Refer to Figure 122 NOTE Warm Water Temperature is selectable between 60 and 190 Fahrenheit 16 and 87 Celsius Default temperature value is 13 100 F NOTE Refer to option 82 to select Celsius or Fahrenheit display Figure 122 6 Press the START enter keypad when th...

Страница 73: ...ture value number to be entered into electronic control Temperature value is followed by two option columns Option columns state the temperature of the water Temperature Value Fahrenheit F Celsius C 5 60 16 6 65 19 7 70 22 8 75 24 9 80 27 10 85 30 11 90 33 12 95 35 13 100 38 14 105 41 15 110 44 16 115 46 17 120 49 18 125 52 19 130 54 20 135 57 21 140 60 22 145 63 23 150 65 24 155 68 25 160 71 26 1...

Страница 74: ...ease the current Cold Water Temperature value to the desired Cold Water Temperature value selected from Table 13 on the following page Refer to Figure 125 NOTE Cold Water Temperature is selectable between 60 and 190 Fahrenheit 16 and 87 Celsius Default temperature value is 7 70 F NOTE Refer to option 82 to select Celsius or Fahrenheit display Figure 125 6 Press the START enter keypad when the corr...

Страница 75: ...ture value number to be entered into electronic control Temperature value is followed by two option columns Option columns state the temperature of the water Temperature Value Fahrenheit F Celsius C 5 60 16 6 65 19 7 70 22 8 75 24 9 80 27 10 85 30 11 90 33 12 95 35 13 100 38 14 105 41 15 110 44 16 115 46 17 120 49 18 125 52 19 130 54 20 135 57 21 140 60 22 145 63 23 150 65 24 155 68 25 160 71 26 1...

Страница 76: ...s the current number that was selected from Table 14 on the following page 5 Locate the desired number in the first column of Table 14 on the following page NOTE Default PreWash 1 Fill Tumble Dispenser value is 001 6 Press the DELICATES or the COLD keypad to increase or decrease the current number until correct Refer to Figure 128 Figure 128 7 Press the START enter keypad when the correct number a...

Страница 77: ...ue is followed by four option columns Option columns state whether an action is ON or OFF ON indicates option is turned on OFF indicates option is turned off Dispenser Value Dispenser One Dispenser Two Dispenser Three Dispenser Four 000 OFF OFF OFF OFF 001 ON OFF OFF OFF 002 OFF ON OFF OFF 003 ON ON OFF OFF 004 OFF OFF ON OFF 005 ON OFF ON OFF 006 OFF ON ON OFF 007 ON ON ON OFF 008 OFF OFF OFF ON ...

Страница 78: ...D is the current number that was selected from Table 15 on the following page 5 Locate the desired number in the first column of Table 15 on the following page NOTE Default PreWash 2 Fill Tumble Dispenser value is 001 6 Press the DELICATES or the COLD keypad to increase or decrease the current number until correct Refer to Figure 131 Figure 131 7 Press the START enter keypad when the correct numbe...

Страница 79: ...ue is followed by four option columns Option columns state whether an action is ON or OFF ON indicates option is turned on OFF indicates option is turned off Dispenser Value Dispenser One Dispenser Two Dispenser Three Dispenser Four 000 OFF OFF OFF OFF 001 ON OFF OFF OFF 002 OFF ON OFF OFF 003 ON ON OFF OFF 004 OFF OFF ON OFF 005 ON OFF ON OFF 006 OFF ON ON OFF 007 ON ON ON OFF 008 OFF OFF OFF ON ...

Страница 80: ...current number that was selected from Table 16 on the following page 5 Locate the desired number in the first column of Table 16 on the following page NOTE Default Wash Fill Tumble Dispenser value is 003 6 Press the DELICATES or the COLD keypad to increase or decrease the current number until correct Refer to Figure 134 Figure 134 7 Press the START enter keypad when the correct number appears in t...

Страница 81: ...ue is followed by four option columns Option columns state whether an action is ON or OFF ON indicates option is turned on OFF indicates option is turned off Dispenser Value Dispenser One Dispenser Two Dispenser Three Dispenser Four 000 OFF OFF OFF OFF 001 ON OFF OFF OFF 002 OFF ON OFF OFF 003 ON ON OFF OFF 004 OFF OFF ON OFF 005 ON OFF ON OFF 006 OFF ON ON OFF 007 ON ON ON OFF 008 OFF OFF OFF ON ...

Страница 82: ...is the current number that was selected from Table 17 on the following page 5 Locate the desired number in the first column of Table 17 on the following page NOTE Default Rinse 1 Fill Tumble Dispenser value is 003 6 Press the DELICATES or the COLD keypad to increase or decrease the current number until correct Refer to Figure 137 Figure 137 7 Press the START enter keypad when the correct number ap...

Страница 83: ...ue is followed by four option columns Option columns state whether an action is ON or OFF ON indicates option is turned on OFF indicates option is turned off Dispenser Value Dispenser One Dispenser Two Dispenser Three Dispenser Four 000 OFF OFF OFF OFF 001 ON OFF OFF OFF 002 OFF ON OFF OFF 003 ON ON OFF OFF 004 OFF OFF ON OFF 005 ON OFF ON OFF 006 OFF ON ON OFF 007 ON ON ON OFF 008 OFF OFF OFF ON ...

Страница 84: ... is the current number that was selected from Table 18 on the following page 5 Locate the desired number in the first column of Table 18 on the following page NOTE Default Rinse Extra Fill Tumble Dispenser value is 003 6 Press the DELICATES or the COLD keypad to increase or decrease the current number until correct Refer to Figure 140 Figure 140 7 Press the START enter keypad when the correct numb...

Страница 85: ...ue is followed by four option columns Option columns state whether an action is ON or OFF ON indicates option is turned on OFF indicates option is turned off Dispenser Value Dispenser One Dispenser Two Dispenser Three Dispenser Four 000 OFF OFF OFF OFF 001 ON OFF OFF OFF 002 OFF ON OFF OFF 003 ON ON OFF OFF 004 OFF OFF ON OFF 005 ON OFF ON OFF 006 OFF ON ON OFF 007 ON ON ON OFF 008 OFF OFF OFF ON ...

Страница 86: ...VFD is the current number that was selected from Table 19 on the following page 5 Locate the desired number in the first column of Table 19 on the following page NOTE Default Rinse Final Fill Tumble Dispenser value is 006 6 Press the DELICATES or the COLD keypad to increase or decrease the current number until correct Refer to Figure 143 Figure 143 7 Press the START enter keypad when the correct n...

Страница 87: ...ue is followed by four option columns Option columns state whether an action is ON or OFF ON indicates option is turned on OFF indicates option is turned off Dispenser Value Dispenser One Dispenser Two Dispenser Three Dispenser Four 000 OFF OFF OFF OFF 001 ON OFF OFF OFF 002 OFF ON OFF OFF 003 ON ON OFF OFF 004 OFF OFF ON OFF 005 ON OFF ON OFF 006 OFF ON ON OFF 007 ON ON ON OFF 008 OFF OFF OFF ON ...

Страница 88: ...ash 1 Fill and Tumble will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 146 NOTE Default output value is 001 Figure 146 6 Press the START enter keypad when the correct value appears in the VFD The next option 094 will appear in the VFD NOTE To program 094 PreWash 1 Drain ...

Страница 89: ...s turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated valv...

Страница 90: ...reWash 1 Drain Tumble Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 149 NOTE Default output value is 002 Figure 149 6 Press the START enter keypad when the correct value appears in the VFD The next option 095 will appear in the VFD NOTE To program 095 PreWash 1 ...

Страница 91: ...s turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated valv...

Страница 92: ... Extract Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 152 NOTE Default output value is 002 Figure 152 6 Press the START enter keypad when the correct value appears in the VFD The next option 096 will appear in the VFD NOTE To program 096 PreWash 2 Fill Tumble D...

Страница 93: ...s turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated valv...

Страница 94: ...sh 2 Fill Tumble Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 155 NOTE Default output value is 001 Figure 155 6 Press the START enter keypad when the correct value appears in the VFD The next option 097 will appear in the VFD NOTE To program 097 PreWash 2 Drain...

Страница 95: ...s turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated valv...

Страница 96: ...reWash 2 Drain Tumble Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 158 NOTE Default output value is 002 Figure 158 6 Press the START enter keypad when the correct value appears in the VFD The next option 098 will appear in the VFD NOTE To program 098 PreWash 2 ...

Страница 97: ...s turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated valv...

Страница 98: ...h 2 Extract Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 161 NOTE Default output value is 002 Figure 161 6 Press the START enter keypad when the correct value appears in the VFD The next option 099 will appear in the VFD NOTE To program 099 Wash Fill Tumble Dra...

Страница 99: ...s turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated valv...

Страница 100: ...l Tumble Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 164 NOTE Default output value is 001 Figure 164 6 Press the START enter keypad when the correct value appears in the VFD The next option 100 will appear in the VFD NOTE To program 100 Wash Drain Tumble Drain...

Страница 101: ...s turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated valv...

Страница 102: ...h Drain Tumble Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 167 NOTE Default output value is 002 Figure 167 6 Press the START enter keypad when the correct value appears in the VFD The next option 101 will appear in the VFD NOTE To program 101 Wash Extract Drai...

Страница 103: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 104: ... Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 170 NOTE Default output value is 002 Figure 170 6 Press the START enter keypad when the correct value appears in the VFD The next option 102 will appear in the VFD NOTE To program 102 Rinse 1 Fill Tumble Drain refer...

Страница 105: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 106: ...Rinse 1 Fill Tumble Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 173 NOTE Default output value is 001 Figure 173 6 Press the START enter keypad when the correct value appears in the VFD The next option 103 will appear in the VFD NOTE To program 103 Rinse 1 Drai...

Страница 107: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 108: ...he Rinse 1 Drain Tumble Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 176 NOTE Default output value is 002 Figure 176 6 Press the START enter keypad when the correct value appears in the VFD The next option 104 will appear in the VFD NOTE To program 104 Rinse 1 ...

Страница 109: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 110: ...ract Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 179 NOTE Default output value is 002 Figure 179 6 Press the START enter keypad when the correct value appears in the VFD The next option 105 will appear in the VFD NOTE To program 105 Rinse Extra Fill Tumble Dra...

Страница 111: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 112: ...se Extra Fill Tumble Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 182 NOTE Default output value is 001 Figure 182 6 Press the START enter keypad when the correct value appears in the VFD The next option 106 will appear in the VFD NOTE To program 106 Rinse Extra...

Страница 113: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 114: ...Rinse Extra Drain Tumble Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 185 NOTE Default output value is 002 Figure 185 6 Press the START enter keypad when the correct value appears in the VFD The next option 107 will appear in the VFD NOTE To program 107 Rinse E...

Страница 115: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 116: ...xtra Extract Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 188 NOTE Default output value is 002 Figure 188 6 Press the START enter keypad when the correct value appears in the VFD The next option 108 will appear in the VFD NOTE To program 108 Rinse Final Fill Tu...

Страница 117: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 118: ...se Final Fill Tumble Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 191 NOTE Default output value is 001 Figure 191 6 Press the START enter keypad when the correct value appears in the VFD The next option 109 will appear in the VFD NOTE To program 109 Rinse Final...

Страница 119: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 120: ...Rinse Final Drain Tumble Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 194 NOTE Default output value is 002 Figure 194 6 Press the START enter keypad when the correct value appears in the VFD The next option 110 will appear in the VFD NOTE To program 110 Rinse F...

Страница 121: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 122: ...nse Final Extract Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 197 NOTE Default output value is 002 Figure 197 6 Press the START enter keypad when the correct value appears in the VFD The next option 111 will appear in the VFD NOTE To program 111 Spin Extract D...

Страница 123: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 124: ...act Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 200 NOTE Default output value is 002 Figure 200 6 Press the START enter keypad when the correct value appears in the VFD The next option 112 will appear in the VFD NOTE To program 112 Spin Shakeout Drain refer to...

Страница 125: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 126: ...hakeout Drain will appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current output value displayed in the VFD to the desired output value Refer to Figure 203 NOTE Default output value is 002 Figure 203 6 Press the START enter keypad when the correct value appears in the VFD The next option 113 will appear in the VFD NOTE To program 113 Water Inlet refer to opt...

Страница 127: ...is turned on OFF indicates option is turned off Table Options All options OFF Water will not be drained from cylinder and water will be used for next period of cycle for pump models only Auxiliary Drain Sends signal to an optional auxiliary drain control Electric Pump Water will be pumped from cylinder to increase removal time Dump Valve Water will be drained through an electronically operated val...

Страница 128: ...appear in the VFD 5 Press the DELICATES or the COLD keypad to increase or decrease the current value to the desired value Refer to Figure 206 Figure 206 6 Press the START enter keypad when the correct value appears in the VFD The next option 114 will appear in the VFD NOTE To program 114 Lucky Option refer to option 114 in Programming NetMaster in the Basic Programming Guide To program other optio...

Страница 129: ...andard Auxiliary Standard Standard 012 Standard Standard Auxiliary Auxiliary Standard Standard 013 Auxiliary Standard Auxiliary Auxiliary Standard Standard 014 Standard Auxiliary Auxiliary Auxiliary Standard Standard 015 Auxiliary Auxiliary Auxiliary Auxiliary Standard Standard 016 Standard Standard Standard Standard Auxiliary Standard 017 Auxiliary Standard Standard Standard Auxiliary Standard 01...

Страница 130: ...ary 046 Standard Auxiliary Auxiliary Auxiliary Standard Auxiliary 047 Auxiliary Auxiliary Auxiliary Auxiliary Standard Auxiliary 048 Standard Standard Standard Standard Auxiliary Auxiliary 049 Auxiliary Standard Standard Standard Auxiliary Auxiliary 050 Standard Auxiliary Standard Standard Auxiliary Auxiliary 051 Auxiliary Auxiliary Standard Standard Auxiliary Auxiliary 052 Standard Standard Auxil...

Страница 131: ...rresponds to the current Special Cycle Option Programming Value 5 Locate the desired number in the first column of Table 41 on the following page 6 Press the DELICATES or the COLD keypad to increase or decrease the current number until correct Refer to Figure 209 Figure 209 7 Press the START enter keypad when the correct number appears in the VFD The next option 116 will appear in the VFD NOTE To ...

Страница 132: ...ntrol Special Cycle value is followed by three option columns Option columns state whether an action is ON or OFF ON indicates option is turned on OFF indicates option is turned off NOTE Very High Speed is available on Variable Frequency Drive models NCV NRV or NXV only Special Cycle Value Special Cycle Option Off On Very High Speed in Final Extract Step Warm Water in Final Rinse Step 000 OFF OFF ...

Страница 133: ... decrease the current number of minutes displayed in the VFD to the desired number of minutes Refer to Figure 212 NOTE The Special Cycle Extra Wash Fill Agitate Time can be set from zero 0 to 15 minutes Figure 212 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 117 will appear in the VFD NOTE The Special Cycle option needs to be turned on refer ...

Страница 134: ... decrease the current number of minutes displayed in the VFD to the desired number of minutes Refer to Figure 215 NOTE The Special Cycle Extra Rinse Extra Fill Agitate Time can be set from zero 0 to 15 minutes Figure 215 6 Press the START enter keypad when the correct number of minutes appears in the VFD The next option 118 will appear in the VFD NOTE The Special Cycle option needs to be turned on...

Страница 135: ...6 3 Press the DELICATES or the COLD keypad to scroll through the programmable options until 122 appears in the VFD Refer to Figure 217 Figure 217 4 When 122 appears in the VFD press the START enter keypad There are five digits in Site Code 1 The fifth digit will appear in the VFD and will flash one second on one second off Refer to Figure 218 Figure 218 5 Press the DELICATES or the COLD keypad to ...

Страница 136: ... the START enter keypad to enter the value of the digit and advance to the next digit 8 Press the START enter keypad with the last active digit The next option 123 will appear in the VFD NOTE To program 123 Error Code Programming Parameter refer to option 123 To program other options refer to the appropriate section How to Exit Programming Feature 1 Be sure the control shows a programmable option ...

Страница 137: ...rent Error Code Programming Parameter Value 5 Locate the desired number in the first column of Table 42 on the following page 6 Press the DELICATES or the COLD keypad to increase or decrease the current number until correct Refer to Figure 223 Figure 223 7 Press the START enter keypad when the correct number appears in the VFD The next option 124 will appear in the VFD NOTE To program 124 Start Pu...

Страница 138: ... ON 002 OFF OFF OFF OFF ON OFF 003 OFF OFF OFF OFF ON ON 004 OFF OFF OFF ON OFF OFF 005 OFF OFF OFF ON OFF ON 006 OFF OFF OFF ON ON OFF 007 OFF OFF OFF ON ON ON 008 OFF OFF ON OFF OFF OFF 009 OFF OFF ON OFF OFF ON 010 OFF OFF ON OFF ON OFF 011 OFF OFF ON OFF ON ON 012 OFF OFF ON ON OFF OFF 013 OFF OFF ON ON OFF ON 014 OFF OFF ON ON ON OFF 015 OFF OFF ON ON ON ON 016 OFF OFF OFF OFF OFF OFF 017 OFF...

Страница 139: ...045 OFF ON ON ON OFF ON 046 OFF ON ON ON ON OFF 047 OFF ON ON ON ON ON 048 OFF ON OFF OFF OFF OFF 049 OFF ON OFF OFF OFF ON 050 OFF ON OFF OFF ON OFF 051 OFF ON OFF OFF ON ON 052 OFF ON OFF ON OFF OFF 053 OFF ON OFF ON OFF ON 054 OFF ON OFF ON ON OFF 055 OFF ON OFF ON ON ON 056 OFF ON ON OFF OFF OFF 057 OFF ON ON OFF OFF ON 058 OFF ON ON OFF ON OFF 059 OFF ON ON OFF ON ON 060 OFF ON ON ON OFF OFF ...

Страница 140: ...FF 083 OFF OFF OFF OFF ON ON 084 OFF OFF OFF ON OFF OFF 085 OFF OFF OFF ON OFF ON 086 OFF OFF OFF ON ON OFF 087 OFF OFF OFF ON ON ON 088 OFF OFF ON OFF OFF OFF 089 OFF OFF ON OFF OFF ON 090 OFF OFF ON OFF ON OFF 091 OFF OFF ON OFF ON ON 092 OFF OFF ON ON OFF OFF 093 OFF OFF ON ON OFF ON 094 OFF OFF ON ON ON OFF 095 OFF OFF ON ON ON ON 096 OFF ON OFF OFF OFF OFF 097 OFF ON OFF OFF OFF ON 098 OFF ON...

Страница 141: ... OFF 121 OFF ON ON OFF OFF ON 122 OFF ON ON OFF ON OFF 123 OFF ON ON OFF ON ON 124 OFF ON ON ON OFF OFF 125 OFF ON ON ON OFF ON 126 OFF ON ON ON ON OFF 127 ON ON ON ON ON ON 128 ON OFF OFF OFF OFF OFF 129 ON OFF OFF OFF OFF ON 130 ON OFF OFF OFF ON OFF 131 ON OFF OFF OFF ON ON 132 ON OFF OFF ON OFF OFF 133 ON OFF OFF ON OFF ON 134 ON OFF OFF ON ON OFF 135 ON OFF OFF ON ON ON 136 ON OFF ON OFF OFF ...

Страница 142: ... ON ON ON OFF 159 ON OFF ON ON ON ON 160 ON ON OFF OFF OFF OFF 161 ON ON OFF OFF OFF ON 162 ON ON OFF OFF ON OFF 163 ON ON OFF OFF ON ON 164 ON ON OFF ON OFF OFF 165 ON ON OFF ON OFF ON 166 ON ON OFF ON ON OFF 167 ON ON OFF ON ON ON 168 ON ON ON OFF OFF OFF 169 ON ON ON OFF OFF ON 170 ON ON ON OFF ON OFF 171 ON ON ON OFF ON ON 172 ON ON ON ON OFF OFF 173 ON ON ON ON OFF ON 174 ON ON ON ON ON OFF 1...

Страница 143: ...FF 197 ON OFF OFF ON OFF ON 198 ON OFF OFF ON ON OFF 199 ON OFF OFF ON ON ON 200 ON OFF ON OFF OFF OFF 201 ON OFF ON OFF OFF ON 202 ON OFF ON OFF ON OFF 203 ON OFF ON OFF ON ON 204 ON OFF ON ON OFF OFF 205 ON OFF ON ON OFF ON 206 ON OFF ON ON ON OFF 207 ON OFF ON ON ON ON 208 ON OFF OFF OFF OFF OFF 209 ON OFF OFF OFF OFF ON 210 ON OFF OFF OFF ON OFF 211 ON OFF OFF OFF ON ON 212 ON OFF OFF ON OFF O...

Страница 144: ...F 231 ON ON OFF ON ON ON 232 ON ON ON OFF OFF OFF 233 ON ON ON OFF OFF ON 234 ON ON ON OFF ON OFF 235 ON ON ON OFF ON ON 236 ON ON ON ON OFF OFF 237 ON ON ON ON OFF ON 238 ON ON ON ON ON OFF 239 ON ON ON ON ON ON 240 ON ON OFF OFF OFF OFF 241 ON ON OFF OFF OFF ON 242 ON ON OFF OFF ON OFF 243 ON ON OFF OFF ON ON 244 ON ON OFF ON OFF OFF 245 ON ON OFF ON OFF ON 246 ON ON OFF ON ON OFF 247 ON ON OFF ...

Страница 145: ...r to Figure 225 Figure 225 4 When 124 appears in the VFD press the START enter keypad A number will appear in the VFD This number corresponds to the current Start Pulse Mode Programming Value 5 Locate the desired number in the first column of Table 43 below 6 Press the DELICATES or the COLD keypad to increase or decrease the current number until correct Refer to Figure 226 Figure 226 7 Press the S...

Страница 146: ......