![Alliance Laundry Systems LES37A*F Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/alliance-laundry-systems/les37a-f/les37a-f_installation-and-operating-manual_2901353022.webp)
Installation
510988
20
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Exhaust System
IMPORTANT: Keep exhaust duct as short as
possible.
NOTE: Be certain old ducts are cleaned before
installing your new dryer.
For best drying results, recommended maximum
length of exhaust system is shown in table below.
To prevent backdraft when dryer is not in operation,
outer end of exhaust pipe must have a weather hood
with hinged dampers (obtain locally).
NOTE: Weather hood should be installed at least
30.5 cm (12 inches) above the ground.
Number of
90° Elbows
Weather Hood Type
Recommended
Use Only for Short Run Installations
Maximum length of 10.2 cm (4 in.) diameter rigid metal duct.
0
19.8 m (64 ft.)
16.8 m (55 ft.)
1
16.8 m (55 ft.)
14.3 m (47 ft.)
2
14.3 m (47 ft.)
12.5 m (41 ft.)
3
11.0 m (36 ft.)
9.1 m (30 ft.)
4
8.5 m (28 ft.)
6.7 m (22 ft.)
Maximum length of 10.2 cm (4 in.) diameter flexible metal duct.
0
13.7 m (45 ft.)
10.7 m (35 ft.)
1
10.7 m (35 ft.)
8.2 m (27 ft.)
2
9.1 m (30 ft.)
6.4 m (21 ft.)
3
7.6 m (25 ft.)
5.2 m (17 ft.)
4
6.1 m (20 ft.)
4.5 m (15 ft.)
NOTE: Deduct 1.8 m (6 ft.) for each additional elbow.
10.2 cm
(4 in.)
10.2 cm
(4 in.)
D673I
6.35 cm
(2-1/2 in.)
D802I
Содержание LES37A*F
Страница 2: ......
Страница 4: ...2 510988 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...
Страница 8: ...510988 6 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...
Страница 24: ...510988 22 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...
Страница 34: ......