Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
• Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
43. LOWER ACCESS PANEL
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
access panel. Refer to
.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front panel.
44. INVERTER CONTROL
IMPORTANT: Due to the sensitivity of the inverter
control, careful handling is required. As a
precautionary measure, we recommend using a
ground wrist strap when handling the inverter
control. Wrist strap, cord and alligator clip are
designed to carry away any electrostatic charge
from your body and to direct charge to an available
ground. By using this static protection device,
potential electrostatic discharge problems
associated with handling of inverter control will be
minimized. Always handle inverter control by its
metal edges. If a wrist strap is not available, touch
washer while it is plugged in before handling control
to dissipate any charge.
NOTE: New control is supplied in a special anti-
static wrapping and protected by anti-static foam.
While holding control by its metal edges, remove
control from foam and wrapping.
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
access panel. Refer to
.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front panel.
c. Remove screws holding plastic shield to
control.
d. Remove shield.
e. Press in on locking tabs and unplug harness
disconnect blocks and all wires from inverter
control.
NOTE: DO NOT pull on wires, instead, hold board
near appropriate disconnect block and unplug by
pulling on disconnect block.
f. Remove screws holding inverter control to base
Figure 41
H202
S
E1A
S
crew
s
Lower
Acce
ss
Panel
Panel
Locator
s
Figure 42
FLW1683
S
Plastic
Shield
Inverter
Control
Wire
Ties
Base