24
F238000
Section 4 Service Procedures
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer-extractor before servicing.
• Never start the washer-extractor with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer-extractor is properly grounded.
W171
WARNING
33. DISPENSER
a. Insert key into cabinet top lock and turn
clockwise. Lift up on front of cabinet top until
it is just past the rear hinges, or 90 degrees, refer
to
. Lift cabinet top off machine and set
out of way.
NOTE: When reinstalling cabinet top, metal edges
on dispenser opening must be fitted inside of
dispenser.
b. Loosen hose clamps attaching hoses to
dispenser, refer to
NOTE: Mark all hoses and their appropriate
connection before removing hoses so they can be
reinstalled correctly. When reinstalling hoses to
dispenser, DO NOT overtighten hose clamps; if you
do, water will shoot out of dispenser lid.
c. Remove hoses from dispenser and remove
dispenser.
NOTE: If replacing the siphon tube, the long end of
the tube must be placed in the wash compartment.
Figure 14
B013SE1A
SIPHON
TUBE
SIPHON
BREAK
DISPENSER
SOAP
DISPENSER
HOSE