F238000
23
Section 4 Service Procedures
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer-extractor before servicing.
• Never start the washer-extractor with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer-extractor is properly grounded.
W171
WARNING
32. SIPHON BREAK
a. Insert key into cabinet top lock and turn
clockwise. Lift up on front of cabinet top until
it is just past the rear hinges, or 90 degrees, refer
to
. Lift cabinet top off machine and set
out of way.
NOTE: When reinstalling cabinet top, metal edges
on dispenser opening must be fitted inside of
dispenser.
NOTE: Label all hoses and their appropriate nipple
on siphon break before removing hoses.
b. Loosen hose clamps and carefully remove all
hoses from siphon break, refer to
IMPORTANT: Use a hair dryer or similar heating
device to heat ends of hoses where they attach to
siphon break. This will help loosen hoses and
prevent nipples on siphon break from breaking off
when hoses are removed.
NOTE: Pull hoses straight off nipples. If you do not,
nipples may break off siphon break.
c. Remove three screws holding cover to siphon
break and remove cover.
d. Remove nuts holding siphon break to rear
channel and remove siphon break, refer to
Figure 13
B012SE1A
SIPHON
BREAK
COVER
HOSES
SCREW