53277
31
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
35. IMPELLER AND HOUSING
Refer to Figure 26
a. Remove motor and exhaust assembly. Refer to
b. Remove exhaust fan cover. Refer to Paragraph
33.
c. Hold motor pulley securely and unthread
impeller by grabbing fins of impeller or using
7/8" .6 pt. socket.
d. Remove screws and washers holding exhaust
housing to the motor mounting bracket. Refer
to Figure 26.
Figure 25
DRY1202P
TRU-ARC
RING
IDLER
PULLEY
IDLER
SPRING
MOTOR
PULLEY
GROUND
WIRE
MOTOR
CLAMP
SHOULDER
BOLT
Figure 26
D402S
EXHAUSTING HOUSING
ATTACHING SCREWS