background image

© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

Installation/Operation Supplement

19

70278501 (EN)

Electrical Requirements

Grounding Instructions

NOTE: To ensure protection against shock, this 
tumbler MUST be electrically grounded in 
accordance with the local codes or, in the absence 
of local codes, with the latest edition of the National 
Electrical Code ANSI/NFPA No. 70. 

In the event of malfunction or breakdown, grounding 
will reduce the risk of electric shock by providing a 
path of least resistance for electric current. This 
tumbler must be connected to a grounded metal, 
permanent wiring system; or an equipment grounding 
conductor must be run with the circuit conductors and 
connected to the appropriate ground location.

Metal conduit and/or BX cable is not considered 
ground.

Connecting the Neutral from the electrical 
service box to the tumbler ground screw does not 
constitute a ground.

A dedicated ground conduit (wire) must be 
connected between the electrical service box 
ground bar and the tumbler ground screw.

All OPL (non-vend) models are factory-equipped with 
an emergency stop button on the front panel. 

NOTE: Activation of the emergency stop button 
stops all machine control circuit functions, but 
DOES NOT remove all electrical power from 
machine.

NOTE: This manual is only a supplement. Refer to 
installation/operation manual for full instructions.

WARNING

To reduce the risk of electric shock, fire, 
explosion, serious injury or death:
• Disconnect electric power to the tumbler 

before servicing.

• Close gas shut-off valve to gas tumbler 

before servicing.

• Close steam valve to steam tumbler 

before servicing.

• Never start the tumbler with any guards/

panels removed.

• Whenever ground wires are removed 

during servicing, these ground wires 
must be reconnected to ensure that the 
tumbler is properly grounded.

W002

To reduce the risk of fire and electric 
shock, check with a qualified serviceman 
for proper grounding procedures. Improper 
connection of the equipment grounding 
conductor may result in a risk of electric 
shock.

W068

To reduce the risk of fire and electric 
shock, if electrical supply is coming from a 
three phase service, DO NOT connect a 
“High Leg” or “Stinger Leg” to a single 
phase machine. On a three phase machine, 
if there is a “High Leg” or “Stinger Leg” it 
should be connected to L3.

W069

To reduce the risk of electrical shock, 
de-energize the electrical circuit being 
connected to the tumbler before making 
any electrical connections. All electrical 
connections should be made by a qualified 
electrician. Never attempt to connect a live 
circuit.

W409

WARNING

Label all wires prior to disconnection when 
servicing controls. Wiring errors can cause 
improper and dangerous operation. Verify 
proper operation after servicing.

W071

CAUTION

Содержание BO050T

Страница 1: ...ry com Drying Tumblers 50 Pound Capacity 75 Pound Capacity Refer to page 3 for Model Identification Part No 70278501R5EN December 2007 Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine ...

Страница 2: ......

Страница 3: ...ire department Installation and service must be performed by a qualified installer service agency or the gas supplier W052 WARNING FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance W053 To reduce the risk of fire electric shock serious injury or death to persons when using the tumbler unit follow these basic precaution...

Страница 4: ...ions 11 Steam Connection Locations 12 Position and Level the Tumbler 13 Fire Suppression System 14 Water Requirements 14 Water Connections 14 Electrical Requirements 14 Auxiliary Alarm 14 Gas Requirements 15 Natural Gas and Liquefied Petroleum 15 European Gas 16 Exhaust Requirements 18 Make Up Air 18 Venting 18 Electrical Requirements 19 Grounding Instructions 19 Steam Requirements 20 Thermal Oil ...

Страница 5: ...d CHD50G2 CU050L CHD50G2 CU050N DR50G2 BU050L DR50G2 BU050N BU050T CHD50S2 CU050S CU050T DR50S2 BU050S CHD50E2 CU050E DR50E2 BU050E 75 Pound CHD75G2 CU075L CHD75G2 CU075N DR75G2 BU075L DR75G2 BU075N BU075T CHD75S2 CU075S CU075T DR75S2 BU075S CHD75E2 CU075E DR75E2 BU075E 3O DX4 OPL 3V DX4 vended 3X DX4 prep for coin CD rotary coin drop CX prep for coin DO DMP OPL DV DMP vended DX DMP prep for coin ...

Страница 6: ...copyright owner DO NOT COPY or TRANSMIT Installation Operation Supplement 70278501 EN 4 Serial Plate Location TMB803N 1 Serial Plate TMB803N 10 20 40 30 50 60 0 10 5 PUS H TO STA RT HEA T CO OL DO WN HIG H TEM PER ATU RE LOW 15 0 1 1 ...

Страница 7: ...ion of lint dust and dirt 14 The interior of the tumbler and the exhaust duct should be cleaned periodically by qualified service personnel 15 If not installed operated and maintained in accordance with the manufacturer s instructions or if there is damage to or mishandling of this product s components use of this product could expose you to substances in the fuel or from fuel combustion which can...

Страница 8: ...an be done If they are dried wipe out the cylinder with a damp cloth to remove particles of fiberglass 26 Always follow the fabric care instructions supplied by the garment manufacturer 27 Never operate the tumbler with any guards and or panels removed 28 DO NOT operate the tumbler if it is smoking grinding has missing or broken parts 29 DO NOT bypass any safety devices 30 Solvent vapors from dry ...

Страница 9: ...Cylinder Capacity dry weight kg lbs 22 7 50 34 75 Air Outlet Diameter mm in 203 8 203 8 Maximum Static Back Pressure mbar W C I 1 3 0 5 1 3 0 5 Maximum Airflow L sec C F M 354 750 Gas Steam 50 Hz 354 750 Gas Steam 60 Hz 434 920 Electric 354 750 Motor Horsepower Nonreversing Reversing Fan Cylinder 1 2 1 3 1 3 3 4 1 3 1 3 Gas Models Gas Connection 1 2 in NPT 1 2 in NPT Gas Burner Rating Mj hr Btu hr...

Страница 10: ...5 in 1194 mm 47 in 1946 mm 76 625 in 981 mm 38 625 in 838 mm 33 in 749 mm 29 5 in 050 Steam 781 mm 30 75 in 717 mm 28 25 in 1194 mm 47 in 2032 mm 80 in 981 mm 38 625 in 838 mm 33 in 749 mm 29 5 in 075 Gas and Electric 781 mm 30 75 in 717 mm 28 25 in 1346 mm 53 in 1946 mm 76 625 in 981 mm 38 625 in 838 mm 33 in 902 mm 35 5 in 075 Steam 781 mm 30 75 in 717 mm 28 25 in 1346 mm 53 in 2032 mm 80 in 981...

Страница 11: ...ion of the copyright owner DO NOT COPY or TRANSMIT Installation Operation Supplement 9 70278501 EN Horizontal Exhaust Outlet Locations TMB811N TMB811N A B C Models A B C 050 075 137 mm 5 375 in 203 mm 8 in 340 mm 13 375 in ...

Страница 12: ...ht owner DO NOT COPY or TRANSMIT Installation Operation Supplement 70278501 EN 10 Gas Connection Locations TMB812N TMB812N A B Models Diameter A B 050 1 2 in NPT 394 mm 15 5 in 1670 mm 65 75 in 075 1 2 in NPT 400 mm 15 75 in 1670 mm 65 75 in ...

Страница 13: ...T Installation Operation Supplement 11 70278501 EN Electrical Connection Locations NOTE These figures are approximate dimensions only TMB813N TMB813N GAS AND STEAM ELECTRIC A B B A Models A B Gas and Steam 241 mm 9 5 in 1613 mm 63 5 in Electric 483 mm 19 in 1626 mm 64 in ...

Страница 14: ...ght owner DO NOT COPY or TRANSMIT Installation Operation Supplement 70278501 EN 12 Steam Connection Locations TMB814N TMB814N C A B D Models Diameter A B C D 050 075 3 4 in NPT 387 mm 15 25 in 1848 mm 72 75 in 190 mm 7 5 in 1645 mm 64 75 in ...

Страница 15: ...opening at top of machine to aid in removal or installation A removable trim piece may be used to conceal the opening zero clearance allowed for trim 3 102 mm 4 in maximum header thickness 4 305 mm 12 in minimum clearance permitted for remainder 5 Guard 6 Provision for make up air 7 610 mm 24 in minimum 914 mm 36 in recommended for maintenance purposes 8 6 mm 0 25 in recommended for removal or ins...

Страница 16: ...ll void the warranty It is recommended that a filter or strainer be installed in the water supply line Water Connections Figure 2 IMPORTANT Thread hose couplings onto valve connections finger tight then turn 1 4 turn with pliers Do not cross thread or overtighten couplings IMPORTANT Replace all hoses every five years NOTE Longer inlet hoses are available as optional equipment at extra cost if the ...

Страница 17: ...ce gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 3 45 kPa 34 5 mbar 0 5 psi IMPORTANT The installation must comply with local codes NOTE This manual is only a supplement Refer to installation operation manual for full instructions To reduce the risk of fire or explosion DO NOT CONNECT THE GAS LINE TO THE T...

Страница 18: ...configurations Natural Gas regulated governor Liquefied Petroleum L P Gas not regulated no governor Machines configured for Natural Gas regulator governor may be converted to L P Gas not regulated no governor with block open kit Part No M400763 Serial plates are configured for GB IE PT ES IT GR LU CH WARNING To reduce the risk of electric shock fire explosion serious injury or death Disconnect ele...

Страница 19: ... E 20 8 9 050 075 3 7 3 6 2 3 M401000 M401014 LL 25 12 6 050 075 3 7 3 6 2 3 M401000 M401014 L P Gas B P 30 No Governor 050 075 2 1 2 0 2 3 M401003 M400999 B P 50 28 5 050 075 2 1 2 0 2 3 M401003 M400999 NL Natural Gas L 25 12 6 050 075 3 7 3 6 2 3 M401000 M401014 L P Gas B P 30 No Governor 050 075 2 1 2 0 2 3 M401003 M400999 BE FR Natural Gas E 20 25 No Governor 050 075 3 0 2 9 2 3 M401017 N A L ...

Страница 20: ... to prevent the accumulation of lint DO NOT use plastic or thin foil flexible ducts Use exhaust ducts made of sheet metal or other noncombustible material Use duct tape or pop rivets on all seams and joints Verify that old ducts are thoroughly cleaned out before installing new tumbler NOTE The ducts must be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not...

Страница 21: ...e NOTE This manual is only a supplement Refer to installation operation manual for full instructions WARNING To reduce the risk of electric shock fire explosion serious injury or death Disconnect electric power to the tumbler before servicing Close gas shut off valve to gas tumbler before servicing Close steam valve to steam tumbler before servicing Never start the tumbler with any guards panels r...

Страница 22: ...rts Thermal Oil Prep It is the responsibility of the customer to install appropriate coil and heating system for thermal oil prep models Alliance Laundry Systems LLC is not responsible for the performance or safety of the customer installed thermal oil system To ensure proper operation refer to the Specifications and Dimensions section for the BTU input of equivalent steam models Thermal oil syste...

Страница 23: ...f elbows 1 Supply 8 457 mm 18 in Drop 2 305 mm 12 in Riser 9 Solenoid Valve Supplied with machine 3 Shut Off Valve 10 Steam Bonnet 4 Condensate Return Line from Supply Line 11 Flexible Line 5 Return 12 Union 6 Check Valve 13 Trap with Built In Strainer 7 Vacuum Breaker Optional TMB2014N 2 12 6 3 5 1 13 10 9 8 6 7 4 11 Steam Pressure bar PSI Minimum Pipe Diameter Steam Trap Size Pounds Condensate H...

Страница 24: ...der with laundry DO NOT OVERLOAD NOTE Overloading causes slow drying and wrinkling Close loading door Tumbler will not operate with the door open Step 3 Determine Control Type and Temperature Setting Refer to the various controls in the Control Instructions Section pages 23 28 and follow instructions for the appropriate control type The type of fabric being dried will determine the setting Consult...

Страница 25: ...he knob to the right and release it Figure 6 3 Press the PUSH TO START button and hold it in for approximately three 3 seconds Figure 7 IMPORTANT If the loading door or lint panel door is opened during the cycle the heating system will shut off and the motor will stop However the timer will continue to run To restart the cycle both doors must be closed and the PUSH TO START button must be pressed ...

Страница 26: ...versing cylinder rotation setting if applicable 5 Press the PUSH TO START button in and hold it in for approximately three 3 seconds This starts the tumbler cycle IMPORTANT If the loading door or lint panel door is opened during the cycle the heating system will shut off and the motor will stop To restart the cycle both doors must be closed and the PUSH TO START button must be pressed in 6 When th...

Страница 27: ... nonreversing cylinder rotation setting if applicable 5 Press and release START button to start tumbler Display will show minutes remaining before end of cycle IMPORTANT To stop the tumbler at any time during the cycle OPEN DOOR If the loading door or lint panel door is opened during the cycle the heating system will shut off and the motor will stop To restart the cycle both doors must be closed a...

Страница 28: ...HIGH MED LOW or NO HEAT by turning the temperature knob 2 Insert the coin s in the coin slot 3 Press START button to start tumbler IMPORTANT To stop the tumbler at any time during the cycle OPEN DOOR To restart the tumber CLOSE door and press START button 4 When the cycle is complete open door and remove the laundry TMB2147N Figure 18 TMB1492N Figure 19 25C TMB2150N Figure 20 ...

Страница 29: ... will be used Follow steps 4 through 7 to reprogram any program number When finished set DIP switch 8 to OFF The programs are now stored 8 During the Program Mode if the Up Down arrows REV or Display button is not pressed within 10 seconds the default program settings will be used Reversing Operation 1 When the LOCAL reversing operation is selected the reversing times are stored in the EEPROM whic...

Страница 30: ...ntrol Suffixes Figure 22 DMP Coin Features START button to start or resume a cycle TEMP button to select HIGH MEDIUM or LOW temperature Two hidden buttons to increment or decrement the programmable time and temperature options TMB1955N DRYING PERM PRESS COOLING INSTRUCTIONS START TEMP INSERT COIN S SELECT TEMP PUSH START 1 2 3 HIGH MINUTES MEDIUM LOW ...

Страница 31: ...error codes one half second on and one half second off Error codes are separated by a one second pause before the code is repeated LED Color Description Orange Yellow Initialization Green Standby Normal Operation Red Fault Indication Code Table 3 Error Code DGN LED status Fault Type 1 Red Ignition Control Internal Failure 2 2 Red Flashes Gas Valve Not Connected 3 3 Red Flashes Ignition Flame Sense...

Страница 32: ...ead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment Ensuring this product is disposed of correctly will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources...

Отзывы: