Foundation Options
A minimum 3500 psi (refer to rating per supplier) reinforced con-
crete set on a prepared bed is required for all new machine instal-
lations.
NOTE: Do not mount on wooden floors, tile floors, ele-
vated floor levels, stacked multiple base frames, or
over basements or crawl spaces because of the high
extract speed and the G-forces exerted. For 80 models
and larger, do not mount on metal base frames.
Thoroughness of detail must be stressed with all foundation work
to ensure a stable unit installation, eliminating possibilities of ex-
cessive vibration during extract.
WARNING
To reduce the risk of fire, serious injury, property
damage and/or death, install the machine on a level
(within 3/8 inch), uncovered concrete floor of suffi-
cient strength at grade.
W787
For new foundations a mounting bolt template is available at ex-
tra cost or use machine base if available.
The machine must be anchored to a smooth level surface so that
the entire base of the machine is supported and rests on the
mounting surface.
IMPORTANT: Do not permanently support the machine
on only four points with spacers. Grouting is required
and spacers must be removed.
Machine Installation on Existing Floor
The existing floor slab must be reinforced concrete without voids
under slab and meet depth requirements per
. If the floor
meets these requirements and an elevated pad is NOT desired, re-
fer to
If the floor does not meet these requirements and an elevated pad
is NOT desired, refer to
Elevated Pad Installation on Existing Floor
The existing floor slab must meet minimum requirements shown
in
per machine. The floor must be rein-
forced concrete without voids under slab. If the slab meets these
requirements and an elevated pad is desired, refer to
.
Elevated Base Frame Installation on Existing
Floor
The existing floor slab must meet minimum requirements shown
in
Machine Foundation and Pad Installation
floor must be reinforced concrete without voids under slab. Refer
to
and
. If the slab does not meets these re-
quirements and an elevated base frame is desired, refer to
CHM2412N_SVG
Figure 10
New Foundation
If the existing floor slab does not meet the single machine foun-
dation requirements per model and/or a new monolithic founda-
tion is desired, refer to
.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
43
Part No. F8619501ENR11