M413487
47
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
62. REVERSING TIMER
Refer to Figure 23.
a. Remove two attaching screws and cover from
contactor box.
b. Disconnect wires from reversing timer.
NOTE: Refer to wiring diagram when rewiring
timer motor and switches.
c. Remove two screws holding reversing timer to
back wall of contactor box.
d. Remove reversing timer.
63. REVERSING CONTACTOR
Refer to Figure 23.
a. Remove two attaching screws and cover from
contactor box.
b. Disconnect wires from contactor terminals.
NOTE: Refer to wiring diagram when rewiring
reversing contactor.
c. Remove screws holding reversing contactor to
back wall of contactor box.
d. Remove reversing contactor.
CONTACTOR BOX
Figure 23
T341PE3C
TERMINAL
STRIP
DIN
RAIL
FAN MOTOR
CONTACTOR
REVERSING
CONTACTOR
TRANSFORMER
REVERSING
TIMER
TERMINAL