Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
33. GAS VALVE
a. Remove four screws holding access panel to
cabinet. Refer to Figure 1.
b. Lift access panel off top edge of front panel and
pull panel forward. Refer to Figure 1.
c. Close gas shut-off valve. Refer to Figure 9.
d. Disconnect all wires from gas valve terminals
and disconnect gas valve pipe unions.
e. Remove screws holding gas valve and bracket
to stove assembly.
f. Remove gas valve from mounting bracket.
IMPORTANT: When reinstalling gas valve, purge
air and sediment from the gas service line before
connecting it loosely to the tumbler. Purge
remaining air until odor of gas is detected, then
tighten connection. Use pipe compound resistant to
action of Liquid Petroleum Gas (L.P.) on all pipe
threads.
NOTE: Refer to wiring diagram when rewiring gas
valve.
To reduce risk of fire or explosion, check
pipe connections for gas leaks with a non-
corrosive leak detection fluid. Do not use
an open flame to check for gas leaks!
W310
WARNING
Figure 9
T339PE3C
BURNER
TUBE
IGNITER
UNION
NUT
GAS
SHUT-OFF
VALVE
GAS
VALVE
STOVE
HIGH LIMIT
THERMOSTAT
SPUD
HOLDER