background image

NOTE: L.P. gas, 93.1 MJ/m

3

 [2500 Btu/ft

3

], service

must be supplied at 2.75 kPa [11.04 inch] water col-
umn pressure and a vent to the outdoors must be
provided.

4.   If local codes allow the use of flexible gas tubing, connect the

9.5 mm [3/8 inch] NPT (National Pipe Thread) gas connec-
tion at the rear of the dryer to the laundry room’s gas line with
new flexible stainless steel tubing (using design certified Aus-
tralian Gas Association connector only).

IMPORTANT: Use local codes of practice for gas in-
stallation.

This dryer is equipped with jet for Natural gas.

Gas Consump-
tion

Natural

21.9 MJ

L.P.

21.9 MJ

Gas Supply Pres-
sure

Natural

1.13 kPa

L.P.

2.75 kPa

WARNING

To reduce the risk of gas leaks, fire or explosion:

• The dryer must be connected to the type of

gas as shown on nameplate located in the
door recess.

• Use a new flexible stainless steel connector.
• Use pipe joint compound insoluble in L.P. (Liq-

uefied Petroleum) Gas, or Teflon tape, on all
pipe threads.

• Purge air and sediment from gas supply line

before connecting it to the dryer. Before tight-
ening the connection, purge remaining air from
gas line to dryer until odor of gas is detected.
This step is required to prevent gas valve con-
tamination.

• Do not use an open flame to check for gas

leaks. Use a non-corrosive leak detection fluid.

• Any disassembly requiring the use of tools

must be performed by a suitably qualified serv-
ice person.

W316

D246I_SVG

1

4

2

3

1.  

New Stainless Steel Flexible Connector – Use Only If Al-
lowed By Local Codes (Use design AGA certified connec-
tor)

2.  

Pressure Test Point

3.  

External Shut-Off Valve

4.  

3/8 in. NPT Gas Connection

Figure 5

NOTE: When connecting gas supply line, a pressure
test point must be installed downstream from the
shutoff valve for checking inlet gas pressure.

5.   The gas line to your laundry room should be made of black

iron pipe. A 9.5 mm [3/8 inch] pipe with an inside diameter of
11.7 mm [0.46 inch] will be adequate if length of supply line
is not over 6 m [20 feet]. If length exceeds this, use 12.7 mm
[1/2 inch] pipe. If copper semi-rigid tubing is used it must be
internally tinned or equivalently treated to resist sulfur corro-
sion.

NOTE: The dryer and its individual gas valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 3.45 kPa [1/2 psig].

6.   Check all pipe connections (internal and external) for gas

leaks with a soapy solution. Gas connections should be
checked annually for leakage.

7.   The dryer gas valve is equipped with a pressure test point for

checking manifold pressure.

For proper operation at altitudes above 760 m [2500 feet] the gas
valve spud orifice size must be reduced to ensure complete com-
bustion. Refer to 

Table 3 

and 

Table 4 

.

Installation

©

 Copyright, Alliance Laundry Systems LLC -

 DO NOT COPY or TRANSMIT

  13

  Part No. D516105R2

Содержание ADEE9BGS433XW34

Страница 1: ...inal Instructions Keep These Instructions for Future Reference CAUTION Read the instructions before using the machine If this machine changes ownership this manual must accompany machine www alliancel...

Страница 2: ......

Страница 3: ...to be followed if the dryer user smells gas The gas utility instructions plus the SAFETY and WARNING note directly above must be posted in a prominent location near the dryer for customer use WARNING...

Страница 4: ...ipe Out Inside of Dryer 15 Plug In the Dryer 15 Electrical Requirements 15 Earth Ground Instructions 17 Recheck Steps 17 Check Heat Source 17 Electric Dryers 17 Gas Dryers 17 All Dryers 18 Installer C...

Страница 5: ...Model Identification Information in this manual is applicable to these dryer models ADEE9BGS433XW34 ADEE9BSS433XN34 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 5 Part...

Страница 6: ...mm 26 875 in G 114 mm 4 5 in H 10 mm 0 4 in I 203 mm 8 in J 711 mm 28 in K 597 mm 23 5 in NOTE Exhaust openings are 102 mm 4 inch metal ducting With leveling legs turned into base Gas Models DRY2639N...

Страница 7: ...s turned into base NOTE Gas models cannot be vented out left side of cabinet because of burner housing IMPORTANT The dryer should have sufficient clear ance around it for needed ventilation and for th...

Страница 8: ...Dryers installed in resi dential garages must be elevated 457 mm 18 inches above the floor No other fuel burning appliance should be installed in the same closet with the dryer The dryer must not be...

Страница 9: ...Door DRY2641N_SVG H E D C A 3 1 Front View Closet Door DRY2637N_SVG F F 2 G 1 Closet Door 2 Centered Air Openings G 2 Openings minimum 3 Outer Wall of Enclosure Figure 3 Installation Copyright Allian...

Страница 10: ...51 mm 2 inches is recommended for utility connection 152 mm 6 inches is recommended when venting through rear of unit Table 1 IMPORTANT In mobile home installations gas dryers MUST be permanently atta...

Страница 11: ...or ceiling Static pressure in exhaust duct should not be greater than 1 5 cm water column 0 6 inches water column for 60 Hertz or 10 mm water column 0 4 inches water column for 50 Hertz measured with...

Страница 12: ...st comply with the Gas Installations Standard AS NZS 5601 Part 1 Gener al Installations In the absence of local codes and ordi nances applicable National codes should be followed 1 Install the dryer w...

Страница 13: ...ng the use of tools must be performed by a suitably qualified serv ice person W316 D246I_SVG 1 4 2 3 1 New Stainless Steel Flexible Connector Use Only If Al lowed By Local Codes Use design AGA certifi...

Страница 14: ...0 60941 Table 4 Reverse Door if Desired NOTE Doors with windows cannot be reversed The door on this dryer is completely reversible To reverse door proceed as follows 1 Remove four hinge attaching scre...

Страница 15: ...14 Wipe Out Inside of Dryer Before using dryer for the first time use an all purpose clean er or a detergent and water solution and a damp cloth to re move shipping dust from inside dryer drum DRY250...

Страница 16: ...ess of moisture W563 If the supply cord is damaged it must be replaced by the manu facturer its special agent or similarly qualified persons in order to avoid a hazard DRY2746N_SVG 1 2 3 4 1 Lead In C...

Страница 17: ...h ground W886 If the electrical supply does not meet the above specifications and or you are not sure your building has an effective earth ground have a qualified electrician or your local electrical...

Страница 18: ...st air or exhaust pipe should be warm Shut off Valve Only Applicable on Certain Models DRY2753N_SVG 3 1 6 5 4 2 1 Air Shutter Lockscrew 2 Air Shutter 3 3 1 mm 1 8 in Pipe Plug For checking manifold pr...

Страница 19: ...er to Electrical Power DRY1958N_SVG1 CHECK CHECK 3 GAS ONLY Connect Gas Sup ply Pipe Check for Gas Leaks D233I_SVG1 7 Recheck Steps CHECK CHECK 4 Reverse Door if De sired DRY2052N_SVG1 8 Start and Run...

Отзывы: