NOTE: L.P. gas, 93.1 MJ/m
3
[2500 Btu/ft
3
], service
must be supplied at 2.75 kPa [11.04 inch] water col-
umn pressure and a vent to the outdoors must be
provided.
4. If local codes allow the use of flexible gas tubing, connect the
9.5 mm [3/8 inch] NPT (National Pipe Thread) gas connec-
tion at the rear of the dryer to the laundry room’s gas line with
new flexible stainless steel tubing (using design certified Aus-
tralian Gas Association connector only).
IMPORTANT: Use local codes of practice for gas in-
stallation.
This dryer is equipped with jet for Natural gas.
Gas Consump-
tion
Natural
21.9 MJ
L.P.
21.9 MJ
Gas Supply Pres-
sure
Natural
1.13 kPa
L.P.
2.75 kPa
WARNING
To reduce the risk of gas leaks, fire or explosion:
• The dryer must be connected to the type of
gas as shown on nameplate located in the
door recess.
• Use a new flexible stainless steel connector.
• Use pipe joint compound insoluble in L.P. (Liq-
uefied Petroleum) Gas, or Teflon tape, on all
pipe threads.
• Purge air and sediment from gas supply line
before connecting it to the dryer. Before tight-
ening the connection, purge remaining air from
gas line to dryer until odor of gas is detected.
This step is required to prevent gas valve con-
tamination.
• Do not use an open flame to check for gas
leaks. Use a non-corrosive leak detection fluid.
• Any disassembly requiring the use of tools
must be performed by a suitably qualified serv-
ice person.
W316
D246I_SVG
1
4
2
3
1.
New Stainless Steel Flexible Connector – Use Only If Al-
lowed By Local Codes (Use design AGA certified connec-
tor)
2.
Pressure Test Point
3.
External Shut-Off Valve
4.
3/8 in. NPT Gas Connection
Figure 5
NOTE: When connecting gas supply line, a pressure
test point must be installed downstream from the
shutoff valve for checking inlet gas pressure.
5. The gas line to your laundry room should be made of black
iron pipe. A 9.5 mm [3/8 inch] pipe with an inside diameter of
11.7 mm [0.46 inch] will be adequate if length of supply line
is not over 6 m [20 feet]. If length exceeds this, use 12.7 mm
[1/2 inch] pipe. If copper semi-rigid tubing is used it must be
internally tinned or equivalently treated to resist sulfur corro-
sion.
NOTE: The dryer and its individual gas valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 3.45 kPa [1/2 psig].
6. Check all pipe connections (internal and external) for gas
leaks with a soapy solution. Gas connections should be
checked annually for leakage.
7. The dryer gas valve is equipped with a pressure test point for
checking manifold pressure.
For proper operation at altitudes above 760 m [2500 feet] the gas
valve spud orifice size must be reduced to ensure complete com-
bustion. Refer to
Table 3
and
Table 4
.
Installation
©