![Alliance Laundry Systems 802702R4 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/alliance-laundry-systems/802702r4/802702r4_installation-and-operation-manual_2901647025.webp)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
23
802702
Multi-Dryer Installation Exhaust
Requirements
shows a typical example of a multiple dryer
installation. Note how each dryer has its own exhaust
system vented to the central exhaust duct.
Figure 20
SWD798N
1
58786 Backdraft Damper
(Available through your local authorized parts
source)
3
Weather Hood or Sweep Elbow
(No cap or screen)
2
Clean Out Cover (must be provided).
Inspect monthly.
SWD798N
2
1
3
24 in. (61 cm)
MINIMUM
CLEARANCE TO