Steam Requirements 

NOTE: The maximum allowable steam pressure 
for use with 60 Hertz or 50 Hertz tumblers is 
125 psig (8.6 bar). In no case may the pressure 
exceed the above value.

Obtain specific steam service pipe sizes from the 
steam system supplier or a qualified steam fitter.

Refer to 

Figure 15

 for proper steam pipe 

configurations.

To prevent condensate draining from headers to 
tumbler, piping should have a minimum 12 inch 
rise (305 mm) above respective header. Do not 
make steam connection to header with a 
horizontal or downward facing tee or elbow.

Whenever possible, horizontal runs of steam 
lines must drain, by gravity, to respective steam 
header. Water pockets, or an improperly drained 
steam header, will provide wet steam, causing 
improper operation of tumbler. If pockets or 
improper drainage cannot be eliminated, install a 
bypass trap to drain condensate from the low 
point in the steam header to the return.

In both steam supply and steam return line, it is 
recommended that each have a pipe union and 
shut-off valve. This will enable you to disconnect 
the steam connections and service the tumbler 
while your laundry facility is in operation.

Connect the steam solenoid valve to the related 
steam coil inlet connection with nipples, flex 
hoses, unions and tee.

Strainers may require cleaning due to materials 
from hoses or pipes.

Install bucket trap with built-in strainer and 
check valve. A vacuum breaker is optional. For 
successful operation of tumbler, install trap 18 
inches (457 mm) below coil and as near to the 
tumbler as possible. Inspect trap carefully for 
inlet and outlet markings and install according to 
trap manufacturer’s instructions. If steam is 
gravity returned to boiler, omit trap but install 
optional vacuum breaker and check valve in 
return line near tumbler. Gravity return requires 
entire return plumbing be below steam coil 
outlet.

Install union and shut-off valve in return line and 
make final pipe connections to return header.

NOTE: To prevent water hammering, route return 
lines below outlets of steam coils.

Piping Recommendations

Trap each steam coil individually. Always keep 
the trap clean and in good working condition. 
Refer to 

Table 14

 for Trap Sizing. 

When tumbler is on the end of a line of 
equipment, extend header at least 4 feet 
(1.2 meters) beyond tumbler. Install shut-off 
valve, union, check valve and bypass trap at end 
of line. If gravity return to boiler, omit trap.

Insulate steam supply and return line for safety of 
operator and safety while servicing tumbler.

Keep tumbler in good working condition. Repair 
or replace any worn or defective parts.

Table 14 

Steam Trap Sizing

Tumbler 

Model

Number of 

Coil Rating

Steam Trap Size

(lb/hr Condensate)

25, 30 

Pound

4

120

2

105

T30 

4

105

2

95

35 Pound

4

140

2

120

All system components must have a 
125 psig (10 bar) working pressure. 
Shut-off valves must be installed upstream 
of the steam solenoid valve and 
downstream of each steam trap so 
components can be isolated for 
maintenance or emergency purposes. 

All components (solenoid valve, traps) 
must be supported to minimize loads on 
the tumbler steam coil connections.

W480

WARNING

Содержание 70269701R4

Страница 1: ...nges ownership this manual must accompany machine Drying Tumblers 25 Pound Capacity 30 Pound Capacity 35 Pound Capacity Stacked 30 Pound Capacity Through Serial No 0602004143 Refer to Page 5 for Model...

Страница 2: ......

Страница 3: ...ur building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier cal...

Страница 4: ...2 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70269701 Notes...

Страница 5: ...21 Pre Installation Inspection 21 Location Requirements 21 Tumbler Enclosure 22 Position and Level the Tumbler 23 Installing Accessory Timing Cam 24 Removal of Existing Timing Cam 24 Installation of N...

Страница 6: ...SMIT Electrical Requirements for Electric Models 54 Steam Requirements 57 Piping Recommendations 57 Installing Steam Trap and Making Condensate Return Connections 58 Adjustments 61 Loading Door Switch...

Страница 7: ...0L HA030N HT030D HT030L HT030N HU030L HU030N IPD30G2 IA030L IPD30G2 IA030N IPD30G2 IT030L IPD30G2 IT030N IPD30G2 IU030L IPD30G2 IU030N SA030L SA030N ST030L ST030N SU030L SU030N UA030L UA030N UT030L UT...

Страница 8: ...35S2 BT035S DR35S2 BU035S HT035S HU035S IPD35S2 IT035S IPD35S2 IU035S ST035S SU035S UT035S UU035S YT035S YU035S CHD35E2 CT035E CHD35E2 CU035E DR35E2 BT035E DR35E2 BU035E HT035E HU035E IPD35E2 IT035E I...

Страница 9: ...er portion of the electrical data on the serial plate Serial Plate Location When calling or writing for information about your product be sure to mention model and serial numbers Model and serial numb...

Страница 10: ...70269701 8 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...

Страница 11: ...appearing in this manual are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and carefulness are factors which CANNOT be built...

Страница 12: ...interior of the tumbler and the exhaust duct should be cleaned periodically by qualified service personnel 15 If not installed operated and maintained in accordance with the manufacturer s instructio...

Страница 13: ...they are dried wipe out the cylinder with a damp cloth to remove particles of fiberglass 26 Always follow the fabric care instructions supplied by the garment manufacturer 27 Never operate the tumbler...

Страница 14: ...70269701 12 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...

Страница 15: ...1 4 Maximum Airflow per Pocket C F M l sec 50 Hertz 410 194 410 194 320 151 470 222 60 Hertz 450 212 450 212 350 165 520 245 Maximum Static Back Pressure Inches W C mbar 50 Hertz 0 6 1 5 0 6 1 5 0 8...

Страница 16: ...height of single pocket models to 72 25 inches 1835 mm and 76 25 inches 1938 mm TMB2177N TMB2177N B A C D E Models A B C D E 25 Pound 26 25 in 667 mm 27 5 in 699 mm 40 875 in 1038 mm 63 875 in 1622 mm...

Страница 17: ...70269701 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Cabinet Dimensions T30 T439I T439I A C B D E F Models A B C D E F T30 28 in 711 mm 48 in 1219 mm 10 in 254 mm 42 875 in 1090 mm...

Страница 18: ...st Outlet Locations N A Not Applicable T479I A B C B A 25 30 AND 35 POUND T30 Models Rear Exhaust Diameter A B C 25 30 Pound 6 in 152 mm 3 875 in 99 mm 4 625 in 117 mm N A T30 Elliptical Fits 8 in 203...

Страница 19: ...B C 25 Pound 59 in 1500 mm 1 5 in 38 1 mm 29 in 737 mm 30 Pound 59 in 1500 mm 1 5 in 38 1 mm 35 in 889 mm T30 76 25 in 1936 8 mm 2 5 in 64 mm 30 5 in 775 mm 35 Pound 59 in 1500 mm 2 5 in 64 mm 35 in 8...

Страница 20: ...D C C 25 30 AND 35 POUND ELECTRIC T30 GAS AND STEAM 25 30 AND 35 POUND GAS AND STEAM E T30 ELECTRIC Models Electrical Service Gas and Steam Models Electric Models A B C D E 25 30 Pound 62 25 in 1581 m...

Страница 21: ...All connections use 3 4 inch NPT pipe T481I C D C D A B A B B A 25 30 AND 35 POUND T30 Models Inlet Outlet A C B D 25 30 35 Pound 53 75 in 1365 mm 7 8 in 198 mm 42 5 in 1080 mm 6 5 in 165 mm T30 Uppe...

Страница 22: ...70269701 20 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...

Страница 23: ...umbler fully loaded Floor covering materials such as carpeting or tile should be removed To assure compliance consult local building code requirements The tumbler must not be installed or stored in an...

Страница 24: ...the opening zero clearance allowed for trim 3 4 in 102 mm 4 12 in 305 mm Minimum Clearance 5 24 in 610 mm minimum 36 in 914 mm recommended for maintenance purposes 6 Provision for make up air Minimum...

Страница 25: ...ould be slightly higher than the rear approximately 0 125 inch 3 18 mm This will prevent the clothes while tumbling from wearing on the door glass gasket IMPORTANT Keep tumbler as close to floor as po...

Страница 26: ...llation of New Timing Cam 1 Insert drive into timing cam with wide prong in wide hole of cam 2 Position timing cam and drive fork over the timer shaft aligning the timer flat with the drive fork and t...

Страница 27: ...onger open until the control is reset It may be necessary to retry several times to bleed air from the gas lines To reset open and close the loading door and restart tumbler If lockout condition persi...

Страница 28: ...third family group 3 at 28 37 mbar inlet pressure Regulator governor is blocked open Gas valve CANNOT be field converted to a regulating type Serial plates supplied from the factory are configured for...

Страница 29: ...3 9 4 0 4 0 4 6 1 1 2 1 M402980 M402992 M402992 M411511 L P Gas B P 30 No Governor 25 30 T30 35 2 1 2 2 2 2 2 5 1 1 2 1 M401003 M401011 M401011 M406361 DE Natural Gas E 20 7 6 8 0 8 0 8 0 25 30 T30 35...

Страница 30: ...M402992 M411511 L P Gas 28 or 37 No Governor 25 30 T30 35 2 1 2 2 2 2 2 5 1 1 2 1 M401003 M401011 M401011 M406361 AT Natural Gas H 20 7 6 8 0 8 0 8 0 25 30 T30 35 3 9 4 0 4 0 4 6 1 1 2 1 M402980 M4029...

Страница 31: ...h machine and apply it to the data plate over the ADJUSTED FOR ______ GAS ______ information 5 Commission tumbler for use Figure 6 Specific Conversion Procedures How to Convert Gas Valve from Regulate...

Страница 32: ...rt No 70201901 025S L P Orifice Plate For use on 025S Models L P only 2 Shut Off Valve 3 Gas Valve 8 Required Orifice Injector Pressure 4 Orifice Injector 9 Manometer 5 Regulator Adjusting Housing and...

Страница 33: ...NOTE Blank injectors orifices are available as Part No M400995 How to Adjust Gas Valve Governor Regulator 1 Check gas injector manifold pressure as follows Refer to Figure 7 2 Loosen screw plug inside...

Страница 34: ...70269701 32 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...

Страница 35: ...sted to the outdoors by the shortest possible route Proper sized exhaust ducts are essential for proper operation All elbows should be sweep type Exhaust ducts must be assembled so the interior surfac...

Страница 36: ...ivalent length the diameter of a round duct must be increased by 10 for each additional 20 feet 6 1 meters Cross section area of a rectangular duct must be increased by 20 for each additional 20 feet...

Страница 37: ...t be sized per local codes NOTE Inside of duct must be smooth Do not use sheet metal screws to join sections Consult your local building code for regulations which may also apply TMB2103N 1 Removable...

Страница 38: ...305 mm from the exhaust outlet does not exceed the maximum allowable pressure specified on the installation sticker on the rear of tumbler Static back pressure must be measured with all tumblers vent...

Страница 39: ...s a combustible wall or ceiling the opening must be sized per local codes 2A Outlet Duct Diameter for One Battery 2B Outlet Duct Diameter for Two Batteries 3 45 Typical TMB2019N TMB2018N L K J I H G F...

Страница 40: ...457 mm 15 in 381 mm 22 in 559 mm D 14 in 356 mm 20 in 508 mm 17 in 432 mm 25 in 635 mm E 16 in 406 mm 23 in 584 mm 19 in 483 mm 27 in 686 mm F 18 in 457 mm 26 in 660 mm 21 in 533 mm 30 in 762 mm G 19...

Страница 41: ...ine to each tumbler Refer to Figure 12 Sediment traps Shut off valves Supply pressure taps It is important that equal pressure be maintained at all tumbler gas connections This can best be done by ins...

Страница 42: ...until burner ignites Use pipe compound resistant to actions of L P Gas on all pipe threads Figure 12 Check all pipe connections internal and external for gas leaks using a non corrosive leak detectio...

Страница 43: ...8 m T30 Tumblers 73 000 Btu hr each 7 Minimum pipe size to tumbler is 0 5 in 12 7 mm 35 Pound Tumblers 90 000 Btu hr each SAMPLE CALCULATIONS Equivalent length Total length of main gas supply pipe to...

Страница 44: ...5 40 1 25 40 1 25 31 75 1 25 31 75 1 5 38 10 1 5 38 10 2 50 80 2 50 80 2 50 80 2 50 80 2 50 80 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 3 76 20 3 76 20 3 76 20 3 76 20 3 7...

Страница 45: ...31 2440 26 0 1470 3 7 M401000 55 480 8001 10 000 2441 3050 28 0 1405 3 6 M401014 49 640 L P Gas 2001 6000 610 1830 42 0 0935 2 4 M403017 67 160 6001 8000 1831 2440 43 0 0890 2 3 M406184 55 480 8001 10...

Страница 46: ...70269701 44 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...

Страница 47: ...tton may be installed as specified on the machine wiring diagram NOTE Activation of the emergency stop button stops all machine control circuit functions but DOES NOT remove all electrical power from...

Страница 48: ...Steam T474I 25 30 and 35 Pound Electric T475I T30 Gas or Steam T476I T30 Electric Junction box upper and lower units each unit must be wired separately T474I GROUND LUG CONTROL TRAY V A C TERMINAL BLO...

Страница 49: ...nstructions section of this manual continue with step 1 NOTE The wiring diagram is located inside the junction or contactor box 1 For new service install a circuit breaker or fused disconnect of prope...

Страница 50: ...ingle service connection to TB1 of the upper unit junction box only The serial plate reflects current draw breaker fuse size and conductor amperage required for the entire machine All electric heated...

Страница 51: ...x areas 3 Sign and date conversion sticker located on back of tumbler 4 Follow the instructions covered in Connecting Electrical Service section 240 Volt 60 Hertz 3 Phase 3W G 200 208 Volt 60 Hertz 3...

Страница 52: ...h the dark blue internal jumper 4 Carefully check motor wire connections with wiring diagram and verify that the motors are configured for low voltage operation before replacing covers 5 For stacked t...

Страница 53: ...ng may result in damage to the electronic controls and will void control warranty To Install 1 Immediately after connection of power leads and before applying power to machine locate each of the incom...

Страница 54: ...able 9 Serial Plate Voltage Terminal Block Connections Required Current Amps Recommended Fuse or Breaker Rating Amps Breaker Poles Recommended Minimum Conductor Size AWG mm2 120V 60Hz 1ph L1 Neutral a...

Страница 55: ...nd 22 0 30 1 10 5 26 200 220V 60Hz 1ph L1 Neutral and ground 11 6 15 1 14 2 08 100V 50Hz 1ph L1 Neutral and ground 24 2 35 1 8 8 37 200V 50Hz 1ph L1 Neutral and ground 15 0 20 1 12 3 31 230 240V 50Hz...

Страница 56: ...otor s For 9 kW 25 Pound Electric Models For 12 kW 25 Pound Electric Models Table 11 Serial Plate Voltage Terminal Block Connections Required Current Amps Recommended Fuse or Breaker Rating Amps Break...

Страница 57: ...ground 105 150 1 1 0 53 5 230 240V 50Hz 1ph L1 Neutral and ground 95 125 1 1 42 4 200 208V 60Hz 3ph L1 L2 L3 and ground 62 80 3 4 21 2 200V 50Hz 3ph L1 L2 L3 and ground 60 80 3 4 21 2 230 240V 50Hz 3p...

Страница 58: ...und 107 150 2 1 0 53 5 200V 60Hz 1ph L1 Neutral and ground 122 175 1 2 0 67 5 200V 50Hz 1ph L1 Neutral and ground 119 150 1 1 0 53 5 230 240V 50Hz 1ph L1 Neutral and ground 108 150 1 1 0 53 5 200 208V...

Страница 59: ...ptional For successful operation of tumbler install trap 18 inches 457 mm below coil and as near to the tumbler as possible Inspect trap carefully for inlet and outlet markings and install according t...

Страница 60: ...end of each flexible hose 3 Install a steam trap to each strainer IMPORTANT Steam trap must be installed a minimum of 18 inches 457 mm below the steam coil outlet connections 4 Install a shut off valv...

Страница 61: ...305 mm Riser 7 Vacuum Breaker Optional 3 Condensate Return Line from Supply Line 8 18 in 457 mm Drop 4 Shut Off Valve 9 Solenoid Valve Supplied with machine 5 Check Valve 10 Union Figure 15 T473I 1 2...

Страница 62: ...70269701 60 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...

Страница 63: ...es not operate the switch at the appropriate door closure bend the actuating switch arm in or out to achieve proper actuation CE Models Through Serial No 0208002174 CE tumblers have a second door swit...

Страница 64: ...d closed during the cycle the heating system will shut off The cylinder and fan will continue to operate even though the airflow switch is indicating insufficient airflow Door Strike The door strike m...

Страница 65: ...removed from service perform the following steps where applicable Turn off electrical supply external to machine Turn off electrical disconnect on machine Turn off gas supply external to machine Turn...

Страница 66: ......

Отзывы: