Installation

15

513006

Grounding Information

This appliance must be grounded. In the event of 
malfunction or breakdown, grounding will reduce the 
risk of electric shock by providing a path of least 
resistance for electric current. The cord-kit must be 
equipped with a cord having an equipment-grounding 
conductor and a grounding plug. The plug must be 
plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local 
codes and ordinances.

Do not modify the plug provided with the cord-kit - if 
it will not fit the outlet, have a proper outlet installed 
by a qualified electrician. 

Each dryer has its own terminal block that must be 
connected to a separate branch, 60 Hertz, single phase 
circuit, AC (alternating current) circuit, 

fused at 30 

Amperes

 (the circuit must be fused on both sides of 

the line).

 Electrical service for each dryer should be 

of maximum rated voltage (208 or 240 Volt, 
depending on heating element) listed on the 
nameplate. Do not connect dryer to 110, 115, or 120 
Volt circuit.

Heating elements are available for field installation in 
dryers which are to be connected to electrical service 
of different voltage than that listed on nameplate, such 
as 208 Volt.

NOTE: Branch circuit wire size requirements to 
laundry room outlet are shown in 

Table 4

.

The power cord connection between wall receptacle 
and dryer terminal block 

IS NOT supplied with 

dryer.

 Type of power cord and gauge of wire must 

conform to local codes.

Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock. Check with a qualified 
electrician or service person if you are in 
doubt as to whether the dryer is properly 
grounded.

W038

WARNING

Wire Length

Wire

Less than 

15 ft. (4.5 m)

Listed No. 10 AWG 

Copper wire only

Longer than 

15 ft. (4.5 m)

Listed No. 8 AWG 

Copper wire only

Table 4 

Содержание 513006R3

Страница 1: ...ion www comlaundry com Stacked Clothes Dryer Electric and Gas Models DRY712C Part No 513006R3 August 2011 Keep These Instructions for Future Reference If this machine changes ownership this manual mus...

Страница 2: ......

Страница 3: ...our gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified...

Страница 4: ...er Installation Exhaust Requirements 11 Step 3 Gas Dryer Only Connect Gas Supply Pipe 13 Step 4 Electric Dryer Only Connect Electrical Plug 14 Step 5 Reverse Door if Desired 20 Step 6 Wipe Out Inside...

Страница 5: ...ldren is necessary when the dryer is used near children This is a safety rule for all appliances 5 Before the dryer is removed from service or discarded remove the door to the drying compartment 6 Do...

Страница 6: ...be replaced by a special cord or assembly available from the manufacturer or its service agent 22 Install this dryer according to the INSTALLATION INSTRUCTIONS All connections for electrical power gro...

Страница 7: ...earances that are listed throughout this manual DRY2371N With leveling legs turned into base NOTE Not all models have windows DRY2372N With leveling legs turned into base NOTE Not all models have wind...

Страница 8: ...equipment at extra cost for securing both lower access panels to each dryer base Order Part No 62853 A Torx bit Part No 282P4 is available as optional equipment at extra cost for installing the Torx...

Страница 9: ...lled in the same closet with the dryer The dryer unit must not be installed or stored in an area where it will be exposed to water and or weather The dryer needs sufficient clearance and an adequate a...

Страница 10: ...ency and may void machine warranty DRY2366N 1 Dryer Base 2 Level 3 Leveling Leg 4 Rubber Foot 1 2 3 4 To reduce the risk of fire and combustion gas accumulation the dryer MUST be exhausted to the outd...

Страница 11: ...inches water column 1 5 cm measured with manometer placed on exhaust duct two feet 61 cm from dryer check with dryer running and no load In multi dryer installations all dryers connected to the main...

Страница 12: ...is not in operation outer end of exhaust pipe must have a weather hood with hinged dampers obtain locally NOTE Weather hood should be installed at least 12 inches 30 5 cm above the ground Larger clea...

Страница 13: ...ple dryer installation Note how each dryer has its own exhaust system vented to the central exhaust duct Figure 5 DRY2369N 1 58786 Backdraft Damper Available through your local authorized parts source...

Страница 14: ...ST AIR FLOW MAXIMUM LENGTH OF DUCT 30 feet 9 1 m HORIZONTAL EXHAUST INSTALLATION AIR FLOW D319I 1 Roof 2 Wall 3 2 in 5 cm Minimum 4 NOTE Where the exhaust duct pierces a combustible wall or ceiling an...

Страница 15: ...dryer Make sure you do not damage the pipe threads when removing the cap 3 Connect to gas supply pipe Duct Station Minimum Diameter of Collector Duct A 4 inches 10 2 cm B 8 inches 20 3 cm C 9 inches...

Страница 16: ...as Conversion Kit 458P3 available at extra cost Step 4 Electric Dryer Only Connect Electrical Plug Dryer requires 120 240 Volt or 120 208 Volt 60 Hertz 3 or 4 wire electrical supply Refer to serial pl...

Страница 17: ...he circuit must be fused on both sides of the line Electrical service for each dryer should be of maximum rated voltage 208 or 240 Volt depending on heating element listed on the nameplate Do not conn...

Страница 18: ...ord 3 Strain Relief Nut 4 Strain Relief 1 2 3 4 THREE WIRE 1 2 3 4 FOUR WIRE D679I D680I NOTE Dryer is shown with access cover removed for illustration purposes only NEVER operate the dryer with acces...

Страница 19: ...dryer 2 30 Ampere Fuses or Circuit Breaker 6 Neutral 3 Neutral Wire 7 Terminal Block in Dryer NOTE The power cord is NOT supplied with the electric dryer Type of power cord and gauge of wire must conf...

Страница 20: ...outlet Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet 8 Reinstall access cover and screw Connecting Power Cord wit...

Страница 21: ...lling the white wire loop the free eyelet end of the ground wire removed in Step 3 and attach along with the white wire to the neutral center terminal on the terminal block 7 Tighten all screws firmly...

Страница 22: ...screws 3 Pull bottom of door liner out then pull down removing door liner from door panel 4 Rotate door panel 180 degrees as shown 5 Remove door strike from door liner and reinstall on opposite side 6...

Страница 23: ...ong grounding plug Refer to serial plate for specific electrical requirements NOTE The wiring diagram is located inside the control hood When plugging in the dryer Do not overload circuits Do not use...

Страница 24: ...ian check the polarity of the wall receptacle If a voltage reading is measured other than that illustrated the qualified electrician should correct the problem Do not operate other appliances on the s...

Страница 25: ...lame through lower front panel Adjust the air shutter to obtain a soft uniform blue flame A lazy yellow tipped flame indicates lack of air A harsh roaring very blue flame indicates too much air Adjust...

Страница 26: ...normal machine operation Step 1 Clean Lint Filter Clean lint filter before each use Figure 33 Step 2 Load Laundry Load clothes loosely into dryer drum Add fabric softener sheet if desired IMPORTANT T...

Страница 27: ...TE Always follow manufacturer s care label instructions Step 6 Insert Coin s or Card To Insert Money Insert coin s in coin slot Check pricing as seen on digital display Figure 38 To Insert Card Insert...

Страница 28: ...CARD is lit to prompt the user to insert coins or a card to satisfy the vend price When INSERT COINS CARD is lit the three digits will display the vend price remaining to be satisfied START START is...

Страница 29: ...Control Panel Use only a damp or sudsy cloth for cleaning the control panel Some spray pretreat products may harm the finish on the control panel NOTE The wiring diagram is located inside the control...

Страница 30: ...l reset itself Dryer can be restarted by pressing the START pad If overload protector cycles again remove the dryer from use and call the service person to correct the problem For Energy Conservation...

Страница 31: ...blocked or needs cleaning Check weather hood to make sure flapper moves freely has not been pushed in or has not been blocked Dryer doesn t dry clothes satisfactorily Check exhaust duct to outside to...

Страница 32: ...your dryer PLEASE GIVE THE MODEL AND SERIAL NUMBERS The model and serial numbers are located on the nameplate The nameplate will be in the location shown in the illustration below Please include a co...

Страница 33: ......

Страница 34: ...nnect Dryer Exhaust System H312I H312I 3 GAS ONLY D258I CHECK Connect Gas Supply Pipe Check for Gas Leaks 4 D699I W315IE0A ELECTRIC ONLY Connect Electrical Cord CHECK Reverse Door if Desired 5 D675I C...