Error Display Mode

The control enters Error Display Mode to display 

thermistor errors. The heater is turned off, the 

IN USE

 

LED flashes to indicate the error (refer to paragraphs 

below), and the timer will continue to count down 

time. The control remains in Error Display Mode until 

the control senses the thermistor has returned to an 

acceptable heating range, the cycle ends or machine is 

powered down.

Open Thermistor

If the control senses a temperature less than 0

°

F when 

the heat has been on for at least three minutes it will 

set an open thermistor error. The control will flash the 

IN USE

 LED twice separated by a one and a half 

second pause. This sequence is repeated as long as the 

Open Thermistor error is sensed.

Shorted Thermistor

If the control senses a temperature greater than 210 

±

 

4

°

F during an active cycle it will set a Shorted 

Thermistor error. The control will flash the 

IN USE 

LED three times separated by a one and a half second 

pause. This sequence is repeated as long as the Shorted 

Thermistor error is sensed.

Setting Dry Time Dipswitches

To change the dry time on the dryer, combinations of 

dipswitches can be set on the control.
There are eight dipswitches on the dryer control. The 

first six switches are used to program the amount of 

additional heat time given for each coin pulse. The 

additional drying time is added to the factory default 

minimum heat time of one minute. A value of 1 to 63 

minutes of additional drying time is available for each 

coin slide pulse. 
The last two switches are used to program the amount 

of additional cool down time. The additional cool 

down time is added to the factory default minimum 

cool down time of 3 minutes. A value of 1 to 3 

additional minutes is available.
The control is shipped from the factory programmed 

with 1 minute of minimum heat time, preset with 41 

additional minutes of drying time (dipswitches 1, 4 

and 6 in ON position) and 3 minutes of minimum cool 

down time for a total time of 45 minutes for a coin 

pulse. Refer to 

Table 1

 for dipswitch settings.

The control reads the dipswitch settings at power-up. 

The control must be powered down to change the 

dipswitch settings.
To change the heat or cool down time for a coin pulse, 

the desired dry time dipswitches must be set to ON 

position. All other dipswitches must be in OFF 

position.