background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

5

512042

Installing the Dryer

Step 1: Position and Level the Dryer

Install dryer before washer. This allows room for 
attaching exhaust duct.

Select a location with a solid floor. Dryers installed in 
residential garages must be elevated 18 inches (46 cm) 
above the floor.

No other fuel burning appliance should be installed in 
the same closet with the dryer.

The dryer must not be installed or stored in an area 
where it will be exposed to water and/or weather.

Leveling legs can be adjusted from inside the dryer 
with a 1/4 in. driver. All four legs must rest firmly on 
the floor so the weight of the dryer is evenly 
distributed. The dryer must not rock.

The dryers needs sufficient clearance and an adequate 
air supply for proper operation and ventilation, and for 
easier installation and servicing. (Minimum clearances 
are shown below).

Figure 2 

DRY2053N

**NOTE: For new installations, locate top of wall vent 42 inches (106.7 cm) above floor to make venting 
easier to connect.

DRY2053N

E

E

A

A

D

OUTER WALL OF 

ENCLOSURE

FRONT VIEW

SIDE VIEW

C

B

Area

Description

Closet Installation

A

Dryer sides

0 in. (0 cm)

B

Dryer top (Rear 24 in.)

12 in. (30.5 cm)

C

Dryer rear

4 in. (10.2 cm)

D

Dryer Top (Front 4 in.)

.5 in. (1.3 cm)

E

Exhaust duct clearance to combustible material 2 in. (5.1 cm)

Содержание 512042R4

Страница 1: ...machine www comlaundry com Installation Instructions for Stacked Dryers Dimensions 3 Before You Start 4 Installing the Dryer 5 Installer Checklist Back Cover Date Purchased _____________________ Mode...

Страница 2: ...pplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier W052 FOR YOU...

Страница 3: ...n 13 3 cm 8 0 in 20 3 cm 44 1 in 112 cm 75 38 in 191 5 cm 15 4 in 39 1 cm 37 44 in 95 1 cm 15 44 in 39 2 cm DRY2285N With leveling legs turned into base 1 3 8 in N P T Gas Connection DRY2285N GAS DRYE...

Страница 4: ...re You Start Supplies For most installations the basic supplies you will need are Figure 1 D818I 1 Wrench 2 Screwdrivers 3 Level 4 Teflon Tape 5 Duct Tape 1 2 3 4 5 Any disassembly requiring the use o...

Страница 5: ...side the dryer with a 1 4 in driver All four legs must rest firmly on the floor so the weight of the dryer is evenly distributed The dryer must not rock The dryers needs sufficient clearance and an ad...

Страница 6: ...f fire and combustion gas accumulation the dryer MUST be exhausted to the outdoors W116 To reduce the risk of fire and the accumulation of combustion gases DO NOT exhaust dryer air into a window well...

Страница 7: ...tible construction must be a minimum of 2 inches 5 08 cm For proper operation it is important that the dryer has an ample amount of outside make up air The free area of any opening for the introductio...

Страница 8: ...not in operation outer end of exhaust pipe must have a weather hood with hinged dampers obtain locally NOTE Weather hood should be installed at least 12 inches 30 5 cm above the ground Larger clearan...

Страница 9: ...dryer Make sure you do not damage the pipe threads when removing the cap 3 Connect to gas supply pipe using a new flexible stainless steel connector To reduce the risk of gas leaks fire or explosion...

Страница 10: ...0 Btu ft3 93 1 MJ m3 service must be supplied at 10 1 5 inch water column pressure For proper operation at altitudes above 3000 feet 915 m the L P gas valve spud orifice size must be reduced to ensure...

Страница 11: ...ical service for the dryer should be of maximum rated voltage 208 or 240 Volt depending on heating element listed on the nameplate Do not connect dryer to 110 115 or 120 Volt circuit Heating elements...

Страница 12: ...r Circuit Breaker 6 Neutral 3 Neutral Wire 7 Terminal Block in Dryer NOTE The power cord is NOT supplied with the electric dryer Type of power cord and gauge of wire must conform to local codes and in...

Страница 13: ...ord into an outlet Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet 8 Reinstall access cover and screw Connecting Po...

Страница 14: ...terminal block as follows a Red wire to L1 terminal b Black wire to L2 terminal c White wire to Neutral terminal Figure 15 NOTE When installing the white wire loop the free eyelet end of the ground wi...

Страница 15: ...en pull down removing door liner from door panel 4 Rotate door panel 180 degrees as shown 5 Remove door strike from door liner and reinstall on opposite side 6 Insert liner under flange on bottom of d...

Страница 16: ...plate for specific electrical requirements NOTE The wiring diagram is located behind the control panel inside the control cabinet When plugging in the dryer Do not overload circuits Do not use an ada...

Страница 17: ...meet the above specifications and or if you are not sure the laundry room has an effective ground have a qualified electrician or your local electrical company check it and correct any problems NOTE...

Страница 18: ...ter the dryer has operated for approximately five minutes observe burner flame through lower front panel Adjust the air shutter to obtain a soft uniform blue flame A lazy yellow tipped flame indicates...

Страница 19: ......

Страница 20: ...Connect Dryer Exhaust System CHECK DRY2010N 3 GAS ONLY D258I CHECK Connect Gas Supply Pipe Check for Gas Leaks 4 D699I W315IE0A ELECTRIC ONLY Connect Electrical Cord CHECK Reverse Door if Desired 5 DR...

Отзывы: