One Manifold Assembly
TMB2403N_SVG
L
K
J
I
H
G
F
E
D
C
B
A
1
2
1.
Outlet duct diameter = largest duct diameter based on number of tumble dryers
2.
45° typical
Figure 20
Duct Station
050/075
F75
A
8 in. [203 mm]
10 in. [254 mm]
B
12 in. [305 mm]
15 in. [381 mm]
C
15 in. [381 mm]
18 in. [457 mm]
D
17 in. [432 mm]
21 in. [533 mm]
E
19 in. [483 mm]
24 in. [610 mm]
F
21 in. [533 mm]
26 in. [660 mm]
G
23 in. [584 mm]
28 in. [711 mm]
H
25 in. [635 mm]
30 in. [762 mm]
I
26 in. [660 mm]
32 in. [813 mm]
J
27 in. [686 mm]
33 in. [838 mm]
K
29 in. [737 mm]
35 in. [889 mm]
L
30 in. [762 mm]
36 in. [914 mm]
Table 4
NOTE:
represents tumble dryers with the same
vent size. If multiple vent sizes are used, consult a lo-
cal HVAC specialist.
NOTE: Duct clean-out recommended every 6 feet [0.18
m].
Exhaust Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
40
Part No: 70457901ENR15
Содержание 0904004427
Страница 2: ......