background image

PAGE

  18

www.allfett.net

The warranty period is two years from the date of delivery.
The product including all its components is under the warranty of our company.
In case of defects within the warranty period the period spent in repairing is added to the warranty
period. The repairing period is maximum 30 days. This period starts from the date of delivery of
the product to the services centers or to the seller, the agency the representative, the importer or
the manufacturer of the product respectively, in case there are service centers.
In case the product has material, workmanship or manufacturing defects, the product will be
repaired free of charge and expenses of any sort including labor, the value of the parts replaced
or any our charges.
The product will be replaced free of charge;
  -  If the product permanently disfunctions due to repeating the same defect more than four times
within the warranty period
  -  If the maximum period for repairing is exceeded.
  -  If it is determined that the defect cannot be repaired by report written by the service, or in
the absence of service centers, by the seller, agency, representative, importer or manufacturer of
the product respectively.
The present warranty does not cover damages resulting from importer handling by deviating from
the instructions in the manual.
General administration of protection of consumer rights and competition in the ministry of industry
and commorce may be applied for problems concerning the warranty certificate.

1.
2.
3.

4.

5.

6.

7.

WARRANTY CONDITIONS

DANGEROUS OR HARMFUL CONDITIONS TO ENVIRONMENTAL AND
HUMAN HEALTH DURING USE

All ALLFETT systems are producing according to relevant provisions of security regulations. There

is no risk for environmental and human health during use.

TRANSPORT AND STORAGE

There are no restrictions on transportation by land, air and sea. In general, products should be

stored in a dry and dust-free environment. The storage temperatures are between -10°C and +40°C.

All products are packed with paper based support matarial to reduce damage. Upon receiving the

package please check the items for possible damage.

Содержание Multi Line ALL-25 Series

Страница 1: ...ALL 25 Multi Line Series ELECTRICAL GREASE PUMP INTRODUCTION AND USER MANUAL VERSION 2 00 ...

Страница 2: ...ill be increased INTRODUCTION ABOUT MANUFACTURER With over 25 years experience of manufacturing Centralized Lubrication Systems ALLFETT is able to provide a wide professional approach to select the correct Centralized Lubrication System for industry and heavy machinery A highly accurate manufacturing process is involved in producing Centralized Lubrication Systems in order that systems meet the ve...

Страница 3: ... DESCRIPTION LUBRICANT INFORMATION STANDARD ELECTRICAL CONNECTION OPTIONAL ELECTRICAL CONNECTION RULES TO COMPLY WHILE USING AND WARRANTY CONDITIONS PUMP MAINTENANCE PUMP ELEMENT MAINTENANCE ORDER INFORMATION WARRANTY WARRANTY CONDITIONS PAGE 1 PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 6 PAGE 7 PAGE 8 9 PAGE 10 PAGE 11 PAGE 12 13 PAGE 14 PAGE 15 PAGE 16 PAGE 17 PAGE 18 ...

Страница 4: ...ump body The pump reservoir is manufactured from sheet metal Level of grease is controlled by ALLFETT low level sensor ALL 25 multi line pumps can be controlled and monitored with externall electronic control cards Optional control card feature also displays warnings as broken fuse fault and alarms GENERAL SPECIFICATIONS Reservoir capacities 25 Liters Working temperature 25 C 80 C Grease types NLG...

Страница 5: ...ties Dimension unit is milimeter QUALITY SYSTEM ISO 9001 BUREAU VERITAS Certification This product is produced by ALLFETT Mekanik ve Elektronik Sistemler San Tic Ltd Sti company which is certificated by Bureau Veritas with certificate to compatible for ISO 9001 2008 standard and owner of the quality management system 280mm 270mm 400mm 868mm 425mm ...

Страница 6: ...ers reservoir capacities Optional and standart components are described below TECHNICAL SERVICE Low level indicator Optional Reservoir 25 Liters Reservoir locks Reservoir cover Pum element positions 1 20 Pump body Chassis 380 V AC motor Motor electrical connections Low and high level indicator Optional Follower piston Optional ...

Страница 7: ...coming out from pump elements Displacement volume of the pump element s can be connected to single lubrication point However displacement volume can also be divided by progressive distributor to feed multiple lubrication points Optional system control units Lubrication system and its components can be controlled and monitored with integrated electronic control cards Digital sensores and also press...

Страница 8: ...asing when a lubrication point is blocked Up to 450 bar pressure lubrication system s working pressure can be adjusted by security relief valve Lubricant with over pressure will be out from exhoust hole Pump elements are manufactured in 3 types according to diplacement amounts These types can be described as its piston diameter with Ø5 mm piston pump element s outlet displacement is 5cm minute wit...

Страница 9: ...rmations Lubricant type GREASE Lubricant will be used in the system must certainly be clean and any foreign materials must not enter while filling ALL 25 pumps are designed to use with in centralized lubrication systems only It is not suitable to use ALL 25 pump for lubricant tranfering or circulation purpose To remind that lubricants has content which may hazardous to environment It is important ...

Страница 10: ... NLGI 0 NLGI 1 NLGI 2 R 1 Ø27mm NLGI 0 NLGI 1 NLGI 2 Ø6 x 1 Ø4mm 10 C 0 C 10 C 20 C 30 C 7 5 cm minute 2 4 4 6 4 4 2 7 11 2 7 8 13 20 8 1 44 2 4 3 84 1 14 1 9 3 2 1 3 5 5 6 3 9 6 5 10 4 0 66 1 1 1 76 0 42 0 7 1 12 0 6 1 1 6 1 1 1 8 2 88 2 16 3 6 5 76 0 3 0 5 0 8 0 18 0 3 0 48 0 36 0 6 0 96 0 66 1 1 1 76 1 32 2 2 3 52 0 18 0 3 0 48 0 1 0 18 0 29 0 84 1 4 2 24 0 12 0 2 0 32 0 27 0 45 0 72 0 6 1 1 6 ...

Страница 11: ...ric driven motor Electrical lines must be connected properly as described in schema below Electrical connections are placed on motor Any maintenance on ALL 25 pumps under electrical voltage could lead to personal injury Disconnect all electrical power before any maintenance Electrical connection box 380 V AC Connection R S W1 V1 U1 T 380 V AC Control box connection 380 V AC INPUT I O R S T R S T M...

Страница 12: ... on ALL 25 pumps under electrical voltage could lead to personal injury Disconnect all electrical power before any maintenance Only low level indicator Socket connection 3 2 1 Low level Low level signal Low level Low High level indicator Socket connection 3 2 1 Low level input Low level output Contact connection High level output Contact connection High level input 12 24 V DC 12 24 V DC Low level ...

Страница 13: ... prevent air entrance inside the pomp body Lockable filling cover option can only be used after filling pump from grease nipple up to minimum level 14 Keeping an uncovered cable s during system assembly may cause fatal damages where high voltage is transformed to low voltage Lines must be connected properly to prevent personal injury and damage to property 8 7 Damages coming from voltage fluctuati...

Страница 14: ...ign materials dirt or small particules while filling lead to system units failing and possibly property damage Damages or faults occur from this reason DISQUALIFIES THE WARANTY 15 Disassembling or loosing any part while pump working is prohibited Any damage coming from this reason DISQUALIFIES THE WARANTY Also any personal injury occur from this reason ALLFETT does not accept responsibility 17 Uno...

Страница 15: ...r according to items 10 11 12 13 14 15 and 16 in RULES TO COMPLY WHILE USING AND WARRANTY CONDITIONS If ALLFETT control card is connected the system Electronic control card may be in waiting period Wait until working time starts If necessary control card pass to working period by pressing ADDITIONAL CYCLE button a b c d e Grease inside pump decreased under minimum level Fill the reservoir accordin...

Страница 16: ...ump element s outlet coupling Loose pump element from pump body for 2 3 turns Start to operate pump When grease coming from around pump element body tighten again pump element body to pump Pump should run contiuously untill grease without air is seen from pump element outlet When the grease without air seen from pump element outlet coupling must be tightened to outlet again With this process pump ...

Страница 17: ...ION SALES Ordering numbers Product name Description ALL 25 Multi line Pump 380 V AC 25 Liters Standard ALL 25 Multi line Pump 380 V AC 25 Liters Low level ALL 25 Multi line Pump 380 V AC 25 Liters low High level 10 38 25 CH 10 38 26 CH 10 38 27 CH ...

Страница 18: ... WARRANTY PRODUCER COMPANY FAX TELEPHONE CENTRAL ADRESS NAME ALLFETT Mekanik ve Elektronik Sistemler San ve Tic Ltd Þti 0212 501 33 37 0212 501 32 01 PBX Yeni Eyup Bulvari Topcular Cad Set Ustu No 1 Demirkapý Rami Ýstanbul AUTHORISED PERSON SIGNATURE STAMP PRODUCT TYPE Elektrikli gres pompasý BRAND ALLFETT MODEL SERIAL NUMBER DELIVERY DATE PLACE WARRANTY 2 Years REPAIR TIME 30 days ALL 25 Multi Li...

Страница 19: ... exceeded If it is determined that the defect cannot be repaired by report written by the service or in the absence of service centers by the seller agency representative importer or manufacturer of the product respectively The present warranty does not cover damages resulting from importer handling by deviating from the instructions in the manual General administration of protection of consumer r...

Страница 20: ...PAGE 19 www allfett net ...

Отзывы: