![Allfett LUBMATIC Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/allfett/lubmatic/lubmatic_introduction-and-user-manual_2901068009.webp)
PAGE
8
www.allfett.net
ELECTRICAL CONNECTION
3
1
2
(+)
(-)
DC
ELECTRONIC CONTROL CARD EK-10
Brown cable (+)
Green cable (-)
9 8 7 6 5 4 3 2 1
Contact - (3)
Contact - (1)
PRESSURE SWITCH SOCKET
POWER SUPPLY
(12 or 24 V DC)
Control card connection socket
Transformer is necessary if there is no 24 V DC electrical source. Use minimum 30A
current transformer.
All electrical connections and lines must be checked regularly for damage and to ensure
that they are firmly in place.
Pumps have an electric driven motor. Electrical motor and pressure switch connection cables must
be connected properly as described in schema below.
Electrical motor cables
Pressure switch cables