TECHNICAL FEATURES

Jet nebuliser bowl

Maximum fill: 

8 ml

Aerosol output: 

0.45 ml/min Approx.

Particle size (MMAD)*:  2.1 microns
Manufactured from non toxic material
* The value shown is conservative and in certain conditions may be surpassed

Microbial Contamination

The jet nebuliser bowl and its accessories are for single person use only. If used by other persons cross
infection may occur.

Interactions

The materials used that come into contact with medication have been tested with a wide range of
medication in common use such as ambroxol hydrochloride, ipratropium bromide, bromhexine
hydrochloride, beclomethasone diproprionate, acetylcysteine and salbutamol. However, due to the
variety and continuous evolution of the medication, the possibility of a chemical interaction cannot be
excluded. Once opened, the medication should be used as soon as possible and avoid prolonged
contact between medication and nebuliser.

Disposal

To safeguard the environment, when the appliance has reached the end of its useful life take it
to an authorised electric appliance disposal centre where the raw materials can be recycled.
Please check to see if this is applicable in your area.

TROUBLE SHOOTING

If the 

Ventalair

 

®

 MAX

 fails to operate on 230 volt power:

• Check the electric socket with another appliance or try another electric socket
• Check electric cable for damage
• The 

Ventalair

 

®

 MAX

 is fitted with a thermal fuse which cannot be checked and is not replaceable

• If still not operational return for service

If the jet nebuliser bowl is misting poorly or is taking too long to nebulise your medication:
• Replace your jet nebuliser bowl every 6 months if it is used regularly.
• Check that the centre jet (8b) is in place.
• Check that the hole in the jet (8b) is not blocked with dry medication. Soak the jet nebuliser bowl in

water and try again. Do not tamper with the holes, as this will alter the particle size of your medication.

• Switch pump on and off to ensure air is flowing from the air outlet port (4)
• Check inlet filter (3) for blockage and change if the filter is discoloured
• Check the tubing for leaks, cracks or kinking
• If moisture collects inside air tubing when nebulising medication, disconnect jet nebuliser bowl on

completion, operate pump to pass air through the tube until dry

• Once a year take your nebuliser system to your pharmacy to be checked

CAUTION: Do not dismantle the 

Ventalair

 

®

 MAX

 under any circumstances as this may void your warranty.

Refer servicing to authorised service centre. The 

Ventalair

 

®

 Max

 has an oil free compressor and requires

no servicing. Do not oil.

UNIT TECHNICAL FEATURES

Mod. Ventalair

 

®

 MAX

Voltage

230V~ 50Hz   140VA

Fuse

T 2.5A – 250V 

Continuous use
Air flow

10 l/min

Dynamic air flow:   

6.2 l/min

Dimensions:

180(L) x 300(D) x 120(H) mm

Weight:

1.6 Kg

Manufactured to comply with Medical Directive:
93/42 EECand STD. EN 60 601-1

Operating requirements: 

Temperature min. 10

°

C; max 40

°

C

Air humidity min. 10%; max 95% 

RH

Storage requirements:     

Temperature min. -25

°

C; max 70

°

C

Air humidity min. 10%; max 95% 

RH

Operating/storage atmospheric pressure: min. 690 hPa; max. 1060 hPa 

P

0051

N13211