Allen Organ Company GeniSys Display Скачать руководство пользователя страница 8

Selecting a GeniSys™ Voice:

To change the voice, touch the voice name.  A category 

selection screen will display allowing the selection of 
voices via category or the full list can be displayed. 
To view a list of voices within a category, touch a 
category name,  For example, for all voices relating to 
string style voices, touch the “STRINGS” button.  Use 
the UP and DOWN arrows to move through the voice 
list.  Once the desired voice appears, touch the voice 
name to select it and then touch the BACK button to 
return the voice editing screen.
To view the complete GeniSys voice list, touch the 
“FULL LIST” button.  Again, use the UP and DOWN 
arrows   to   move   through   the   voice   list.     Once   the 
desired voice appears, touch the voice name to select it 
and then touch the BACK button to return the voice 
editing screen.

Adjusting the GAIN (volume):

To change the GAIN (volume) of the selected GeniSys 

Voice, touch the GAIN value to highlight it.   Then, 
use   the   UP   and   DOWN   arrows   to   increase   or 
decrease   the   value.     Touch   the   BACK   button   to 
return   to   the   voice   editing   screen   or   the   HOME 
button to return to the 

Home

 screen.

Note:

   The maximum  amount  of gain available  is 

0dB (loudest) and the least amount of gain available 
is -35dB (softest).

Adjust the Tuning:

The tuning of the selected GeniSys

TM

  voice may be 

adjusted   separately   from   other   available   GeniSys

TM 

Voice position(s) as well as the organ's stops.
To   adjust   the   Tuning,   touch   the   TUNE   button   to 
highlight it.  Then, use the UP and DOWN arrows to 
increase  or decrease  the value.   Touch the BACK 
button to return to the voice  editing screen or the 
HOME button to return to the 

Home

 screen.

Note:

   The tuning may be adjusted ±100 cents from 

A-440 pitch reference.

6

Содержание GeniSys Display

Страница 1: ...GeniSys Display Reference Guide Copyright 2018 Allen Organ Company LLC All Rights Reserved AOC P N 033 00255 3 Revised 3 2020...

Страница 2: ...Pistons 18 2 Restoring Original Factory Settings 19 3 Self Check Stop Action and Capture 19 4 Sostenuto optional requires Sustain Kick Switch 19 5 Modifying Crescendo and Tutti B Settings 20 D MIDI FU...

Страница 3: ...ready to play Important The Allen Organ includes several self testing features If a warning is displayed within this sequence please contact your Allen authorized representative immediately The Home...

Страница 4: ...cking Capture Memories All memories except Memory 1 may be locked or unlocked individually to prevent unintentional or unauthorized changes to that memory s contents Note Memory 1 remains unlocked as...

Страница 5: ...l indicate the selected voicing suite is loading Once the voicing suite has loaded the capture system will automatically cancel all stops indicating the organ is now ready to play Important The organ...

Страница 6: ...Tuning The organ s overall tuning will be changed to the selected Alternate Tuning by actuating the stop control engraved Alternate Tuning Any time the Alternate Tuning stop is turned off the organ wi...

Страница 7: ...y stop controls within the each division of the organ Each division contains two GeniSys Voice stop controls The current GeniSys Voices assigned to the GeniSys Voice stop controls are displayed within...

Страница 8: ...touch the BACK button to return the voice editing screen Adjusting the GAIN volume To change the GAIN volume of the selected GeniSys Voice touch the GAIN value to highlight it Then use the UP and DOWN...

Страница 9: ...e Two Velocity settings are available Normal and Fixed Normal Velocity sensitivity is enabled The GeniSysTM voice will respond to keyboard velocity Fixed Velocity sensitivity is disabled The GeniSysTM...

Страница 10: ...ates how the note range settings can be used to split the keyboard to utilize two different sounds on the same keyboard These settings will allow the first GeniSysTM Voice to play the lower note range...

Страница 11: ...ange value to G8 Synopsis GeniSysTM Voice 5 is setup so the Grand Piano plays normally across the entire range of the Great keyboard However GeniSysTM Voices 3 and 4 are setup so the Swell keyboard is...

Страница 12: ...number Once the desired file number is displayed touch the LOAD button The display will indicate Success if the preset loaded correctly If a User Preset file for the number displayed does not exist t...

Страница 13: ...device If the USB flash device doesn t fit correctly re orient the USB flash device and re insert it into the port socket Once the USB flash device is seated correctly into the port socket the organ w...

Страница 14: ...atus The Recorder Status is located at the bottom of the display and indicates the current status of the recorder Stopped Playing Recording Delete a Song File To delete the selected song file number t...

Страница 15: ...not sound as it was originally recorded Select a piston registration or manually select stops Move the expression shoe s and set them to a desired position Doing this will record the organ s volume i...

Страница 16: ...n Introduction passage is played before the Hymn Note Intro value cannot be changed during playback Tempo Tempo may be adjusted up or down in increments of 10 Maximum tempo value is plus minus 50 Vers...

Страница 17: ...rgan APP available for both Apple and Android products such as an iPhone iPad or Android based device tablet or phone The Allen Organ APP is available for download via the App store for Apple devices...

Страница 18: ...touch the LOAD button Then touch the ACT button to start the load process The display will indicate the status once completed Important If a selected capture file number is not located the display wi...

Страница 19: ...e setting The GeniSysTM Voices registration stored to a piston is a complete setting including all underlying voice parameter settings What s more each capture memory level can contain different sets...

Страница 20: ...y be able to program the MIDI stop controls and will no longer affect other stops To reconfigure a General Piston so it controls only the Swell Division stops Select all of the Swell division stops Pr...

Страница 21: ...s functioning properly and is controllable by the capture system To access the Self Check function touch OPTIONS CONFIGURE CONSOLE MORE SELF CHECK To start the self check touch the START button The bu...

Страница 22: ...SHOW button to highlight and select which mode will be active To view the stops registered on the second B Tutti I or Tutti II press either Tutti piston This will cause all associated stops programme...

Страница 23: ...r the memory settings for the PISTONS are not affected by resetting the Crescendo B Play the Organ Using Crescendo B The Home screen must be displayed Press HOME to return to the Home screen Press the...

Страница 24: ...s capabilities it is suggested that books or literature be referenced which describe how to use MIDI Note Please consult the owner s manual of the external MIDI device s being used for more details of...

Страница 25: ...l send Program Change 1 on MIDI Channel 1 Great Piston 2 will send Program Change 2 on MIDI Channel 2 etc USER Mode In this mode the organ is capable of sending any program change number on any piston...

Страница 26: ...th LOW bank and HIGH bank memory sections This ability can then increase the number of available voices substantially Imagine 128 LOW and HIGH Banks with each Bank containing a possible 128 voices Tha...

Страница 27: ...I Base Channel function touch OPTIONS MIDI MIDI BASE CHANNEL To change the MIDI Base Channel touch the CHANNEL button to highlight it then use the UP and DOWN buttons to change the MIDI channel value...

Страница 28: ...uencer SWELL VOLUME this mode setting causes MIDI expression data to be sent only on the Swell MIDI channel Some early sequencers can only interpret one volume message NO EXPRESSION No MIDI expression...

Страница 29: ...CK button to return to the previous menu screen 10 Transmission Reception of Individual Stop Data This function allows the organist to turn on off the transmission and reception of individual stop dat...

Страница 30: ...ack fast forward and reverse controls that function in the same way as their tape recorder counterparts Types of MIDI Data There are several types of MIDI messages that can be sent from one device to...

Страница 31: ...ing the music using a sequencer and then listening from different locations in the room during the music s playback Other MIDI Uses MIDI has created new possibilities for the organist The ability of t...

Страница 32: ...MIDI devices are connected to the organ it is important to make sure that the devices channels of transmission and reception match the MIDI channels of the Allen Organ divisions to which they are assi...

Страница 33: ...Choir Aahs 54 Voice Oohs 55 Synth Voice 56 Orchestra Hit 57 Trumpet 58 Trombone 59 Tuba 60 Muted Trumpet 61 French Horn 62 Brass Section 63 Synth Brass 1 64 Synth Brass 2 65 Soprano Sax 66 Alto Sax 6...

Страница 34: ...H v 1 127 9nH v 0 9nH v 1 127 9nH v 0 Aftertouch Keys Channels X X X X Pitch Bend O O Control Change 0 bank select 6 Data MSB 7 volume 64 sustain 66 sostenuto 98 NRPN LSB 99 NRPN MSB O O O O O O O X O...

Страница 35: ...APPENDIX B VISUAL NOTE RANGE CHART 33...

Страница 36: ...llustrates that Track 1 contains a Note On event to be transmitted via MIDI for MIDI channel 1 to play note G5 with a velocity value of 64 for a duration of 100 ticks a length measurement used by most...

Страница 37: ...MIDI stop control number system or map which allows a MIDI Song File recorded on one Allen organ to be played back on another Allen organ of the same OR different model If the piston registration chan...

Страница 38: ...op contains an assigned MIDI stop control number value of 132 The number 132 must be split into separate bytes in order for MIDI to be able use it as a valid MIDI stop control number The MIDI event me...

Страница 39: ...SB values First figure the MSB value 290 divided by 128 2 remember only use the whole number value to the left of the decimal as the result the remainder or the numbers to the right of the decimal are...

Страница 40: ...e designed to make sure that you have the freedom to distribute copies of free software and charge for this service if you wish that you receive source code or can get it if you want it that you can c...

Страница 41: ...ified program normally reads commands interactively when run you must cause it when started running for such interactive use in the most ordinary way to print or display an announcement including an a...

Страница 42: ...infringement or for any other reason not limited to patent issues conditions are imposed on you whether by court order agreement or otherwise that contradict the conditions of this License they do not...

Страница 43: ...nd either expressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose The entire risk as to the quality and performance of the prog...

Отзывы: