INSTRUCTION MANUAL
For
D-Meter
®
ALLEN FACE & COMPANY, L.L.C.
338 Arrowhead Dr.
Gilberts, IL 60136
Tel: (224) 699-9000
Fax: (847) 844-0325
Web: www.allenface.com
© 2022 Allen Face & Company, L.L.C. – All rights reserved.
Страница 1: ...INSTRUCTION MANUAL For D Meter ALLEN FACE COMPANY L L C 338 Arrowhead Dr Gilberts IL 60136 Tel 224 699 9000 Fax 847 844 0325 Web www allenface com 2022 Allen Face Company L L C All rights reserved...
Страница 2: ...mmended Run Pattern III 1 Unit Power Up Memory Clearance III 1 Start New Session Query III 1 The OFF Screen III 2 Starting and Completing a Run III 2 Displaying Run Results III 2 Check Codes III 3 Aut...
Страница 3: ...date is displayed on the D Meter s screen every time the unit is turned on Normal turn around time for all factory services is one week excluding transit time D Meters in current calibration are full...
Страница 4: ...ereupon by any party 4 Questionable or troublesome units should be returned immediately to the factory for inspection and repair along with a note describing the problems in detail 5 When returning a...
Страница 5: ...ve to acquire an appropriate battery charger from your local electronics supplier The replacement battery charger should have the following operating characteristics Output Voltage 8 4 volts DC Output...
Страница 6: ...am by clicking on the Run anyway tab Follow the setup instructions Accepting the defaults will work for most installations Once the program is installed a shortcut will appear on your desktop Double c...
Страница 7: ...erence is facilitated 6 Tests can always be easily duplicated in the future 7 Results from different projects can always be reasonably compared B Unit power up Memory Clearance Press the ON button to...
Страница 8: ...ack on During the rotating step the screen on the unit will go blank and the lights will go off this is normal for this operation DO NOT proceed with moving the D Meter to continue the run until the d...
Страница 9: ...own on the OFF and ON screens now consist of two parts the associated session number and the sequential run number Run number 3 14 for example was recorded during the third session and was the fourtee...
Страница 10: ...s all the files have transferred Each download becomes a new Excel Workbook each downloaded session becomes a separate Worksheet in that Workbook and each run becomes a separate Chart on its session s...
Страница 11: ...s for all recorded unvoided runs Aggregate results are displayed for all runs in memory and for all runs contained in each section c VOID PREV RUNS Selects particular run to be deleted beginning with...
Страница 12: ...rr Runs Left rr runs can still be recorded before the memory is full 11 Max Run Length 600 Reminder that the maximum length allowable for any run is 600 feet 12 OFF ss rr ff The OFF screen The unit is...
Страница 13: ...4 Run n Show H s Pressing the GO OK key at this query causes the point elevations on 1 foot centers down run number rr to be displayed sequentially 5 OK Voids Run nn Pressing the GO OK key at this pr...
Страница 14: ...rted ranges between the lower limit aaa a and the upper limit zzz z 9 Chk Code The check code for the current run or session being reported is 10 ff H iiii The profile elevation ff feet from the start...
Страница 15: ...een corrupted Clearing the memory of all runs at unit start up will usually correct this problem If this problem occurs repeatedly however the unit will have to be returned to the factory for service...
Страница 16: ...alculated FF not a number 6 Calculated FF positive infinity 7 Calculated FF negative infinity 8 Calculated 90 Confidence Interval for FF not a number 9 Calculated 90 Confidence Interval for FF positiv...
Страница 17: ...entification fields and type the various specified FF and FL values into the header Save this modified template in a new folder for the project Re open the template you just created and type the test...
Страница 18: ...lecting his test apparatus so that neither ACI nor ASTM could ever be accused of collusion in promoting sales of the Dipstick which was at that time by far the most practical device available for meas...