Rockwell Automation Publication 842E-UM001B-EN-P—April 2015
13
EtherNet/IP overview
Chapter 3
Measuring Range Test
Numerator
Denominator
Measuring
Range (CMR)
Bi-Directional
Rollover Test
Pass/Fail
1
One Rev
Distance Check
Test
2
One Rev Distance
Accuracy (counts)
NOTES
1
1
0
n/a
n/a
n/a
Message Instruction Errors – this is expected
operation
1
1
1
Pass
Pass
0
Position does not change. This is the expected
operation.
1
1
2
Pass
Pass
0
1
1
4
Pass
Pass
0
1
1
8
Pass
Pass
0
1
1
16
Pass
Pass
0
1
1
1,024
Pass
Pass
0
1
1
4,096
Pass
Pass
0
1
1
16,535 Pass
Pass
1
1
1
262,144
Pass
Pass
1
1
1
262,150
Pass
Pass
1
Position Rolls-over @ 262,144
This is expected behavior as the CMR limit is
262,144 based on the following formula
CMR
= (CNR_N / CNR_D) * CPR where CPR =
262,144
1
1
524,288
Pass
Pass
1
Position Rolls-over @ 262,144
This is expected behavior as the CMR limit is
262,144 based on the following formula
CMR
= (CNR_N / CNR_D) * CPR where CPR =
262,144
2
1
524,288
Pass
Pass
1
Position Rolls-over @ 524,288
This is expected behavior as the CMR limit is
262,144 based on the following formula
CMR
= (CNR_N / CNR_D) * CPR where CPR =
262,144
2
1
1,048,576
Pass
Pass
1
Position Rolls-over at 524,288
This is expected behavior as the CMR limit is
524,288 based on the following formula
CMR
= (CNR_N / CNR_D) * CPR where CPR =
262,144
1
1
536,870,912
Pass
Pass
1
Position Rolls-over @ 262,144
Содержание Rockwell Automation 842E-MIP Series
Страница 1: ...842E EtherNet IP Absolute Encoder 842E SIP xxx 842E MIP xxx User Manual ...
Страница 6: ...iv Rockwell Automation Publication 842E UM001B EN P April 2015 About this document Notes ...
Страница 34: ...28 Rockwell Automation Publication 842E UM001B EN P April 2015 Chapter 4 Installation Notes ...
Страница 83: ......