6
Rockwell Automation Publication 20P-IN076B-EN-P - May 2016
PowerFlex DC Drive Frame D Series C to Series C Fan Replacement
Step 5: Install the Series C
Front Top Airflow Plate
1.
Install the series C front airflow plate, tightening the four screws loosened
in Step 2.2. Add and tighten a new hexalobular screw in the center.
Step 6: Install the Series C
Top Protective Cover
Install the series C top protective cover by tightening the four screws loosened in
Step 2.1.
IMPORTANT
The front top airflow plate has to be placed over the rear top airflow plate.
Tool size: T20
1.5 N•m (13.2 lb•in)
Tighten.
Front Top Airflow Plate
Rear Top Airflow Plate
Tool size: T20
1.5 N•m (13.2 lb•in)
Tighten.