Chapter 4
CIP Axis Attributes
304
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
If a specific logical feedback channel, feedback n, is not applicable based on the
current feedback configuration, then attributes for feedback n are not applicable;
no feedback configuration attributes for that channel are set by configuration
software, nor are any such attributes sent to the drive device. This table outlines
these rules:
Feedback Configuration
Feedback 1
Feedback 2
No Feedback
No
No
Master Feedback
Yes
No
Motor Feedback
Yes
No
Load Feedback
Yes
(1)
Yes
Dual Feedback
Yes
Yes
Dual Integrator Feedback
Yes
Yes
(1)
Feedback 1 channel is needed for commutation of PM Motors.
See also
General Feedback Info Attributes
General Feedback Signal Attributes
Feedback Configuration Attributes
The Feedback Configuration attributes determines how the various available
feedback channels are used to implement the selected Control Mode.
Feedback Configuration
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Required - All
Set/GSV
USINT
0 (B, F)
1 (E)
2 (C)
0
15
Enumeration:
0 = No Feedback
1 = Master Feedback
2 = Motor Feedback
3 = Load Feedback
4 = Dual Feedback
5-7 = Reserved
8 = Dual Int Feedback
8-15 = Reserved
When configured, this attribute also sets the initial value for Feedback Mode. This
4-bit enumerated value determines how the various logical feedback channels are
used to implement the selected Control Mode for this axis instance.
Feedback Configuration enumerations provide support for multi-feedback device
control functionality for the various active device Control Modes, for example,
where the device is actively controlling the motor based on feedback. In these
Feedback Configuration
Attributes