Rockwell Automation Publication 2198-IN017A-EN-P - July 2019
3
Kinetix 5100 AC Line Filter
Wiring Examples for the AC Line Filter
Three-Phase Wiring Specifications
Line Filter
Cat. No.
Connects to
Terminals
Recommended
(1)
Wire Size
mm
2
(AWG)
(1)
The actual gauge of the input power wiring depends on the system configuration. Consult your machine builder, the NEC, and applicable local
codes.
AC Line Filter
Strip Length
mm (in.)
Terminal
Torque Values
N•m (lb•in)
2198-DB310-F
0.8…8.4 (18…8)
11.0 (0.43)
1.8 (15.58)
2198-DB324-F
2198-DB335-F
2198-DB356-F
2.5…33.6 (14…3)
15.0 (0.59)
3.4 (30.1)
Single-Phase Wiring Specifications
Line Filter
Cat. No.
Connects to
Terminals
Recommended
(1)
Wire Size
mm
2
(AWG)
(1)
The actual gauge of the input power wiring depends on the system configuration. Consult your machine builder, the NEC, and applicable local
codes.
AC Line Filter
Strip Length
mm (in.)
Terminal
Torque Values
N•m (lb•in)
2198-DB111-F
0.8…8.4 (18…8)
11.0 (0.43)
1.8 (15.58)
2198-DB127-F
L1C
L2C
L1
L2
L3
L1
L2
L3
L1’
L2’
L3’
230V
L1
L2
120/230V
L1C
L2C
L1
L2
L3
Bonded Cabinet
Ground Bar
2198-DB1
xx
F
AC Line Filter
Mains AC Input
Line
Load
Bonded Cabinet
Ground Bar
2198-DB
xxx
-F
AC Line Filter
Mains AC Input
Kinetix 5100 drive input
power connections for
three-phase operation.
Line
Load
Kinetix 5100 drive input
power connections for
single-phase operation.
Circuit
Protection
Circuit
Protection
Circuit
Protection
Circuit
Protection
L1
L2
L3
L1
L2