440
Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Appendix A
Interconnect Diagrams
Digital Output Wiring
In this example, digital output 1 (pin 7+, pin 6–) is connected to an output relay
that changes a contact state used in a PLC or other circuit as shown.
Figure 209 - Digital Output Example
(1) Customer-supplied diode or MOV suppression device.
The I/O connector provides up to six digital outputs. Digital outputs are open-
collector type and are configurable with KNX5100C software.
An example brake circuit contains the following components:
• Digital output 40 mA (max) continuous current.
• Relay 700-HK36Z24 with DIN mount 700-HN121 or equivalent
• Choose from these suppression devices:
– 1N4004 diodes or equivalent
– Bulletin 199-MSMV1 MOV or equivalent
See
Digital Outputs Default Functions
for the default digital output
assignments for Kinetix 5100 drives.
7
6
OUTPUT1–
2198-E
xxxx
-ERS
Kinetix 5100 Servo Drive
I/O Connector with
2198-TBIO Expansion Block
Relay
To PLC or
Other Circuit
Customer Supplied
+24V DC
Note 9
(1)
TIP
Choose relay rated for 40 mA continuous current or less.
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......