194
Rockwell Automation Publication 2097-UM001D-EN-P - November 2012
Appendix B
Input and Output Assembly
Table 74 - Output Assembly Instance (Assembly 114)
In this Output Assembly example, the parameter StartingIndex with a range of
4…7 bytes is expanded to show the low byte, low middle byte, high middle byte,
and high byte. These values are typical for each parameter in
Table 75 - Output Assembly Example
The Attribute Values in this example only apply to Class 374 and not to Class 4
(Assembly Objects).
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Drive En
Reserved
Start Homing
Abort Homing
Define Home
Start Motion
Reserved
Abort Index
1
Reserved
2
Reserved
3
Reserved
4…7
StartingIndex (DINT)
8…11
ReferenceSource (DINT)
12…15
AccelerationLimit (REAL)
16…19
DecelerationLimit (REAL)
20…23
CommandCurrentOrVelocity (REAL)
24…27
VelocityLimit (REAL)
28…31
CommandPosition (REAL)
32…35
RegistrationOffset (REAL)
36…39
UserDefinedIntegerData0 (DINT)
40…43
UserDefinedIntegerData1 (DINT)
44…47
UserDefinedIntegerReal0 (REAL)
48…51
UserDefinedIntegerReal1 (REAL)
Byte
Parameter Value
4
StartingIndex - Low byte
5
StartingIndex - Low middle byte
6
StartingIndex - High middle byte
7
StartingIndex - High byte
Содержание Kinetix 300
Страница 4: ...4 Rockwell Automation Publication 2097 UM001D EN P November 2012 Summary of Changes Notes...
Страница 18: ...18 Rockwell Automation Publication 2097 UM001D EN P November 2012 Chapter 1 Start Notes...
Страница 188: ...188 Rockwell Automation Publication 2097 UM001D EN P November 2012 Appendix A Interconnect Diagrams Notes...
Страница 216: ...216 Rockwell Automation Publication 2097 UM001D EN P November 2012 Appendix D MicroLogix Explicit Messaging Notes...
Страница 229: ...Kinetix 300 EtherNet IP Indexing Servo Drives User Manual...
Страница 230: ......