background image

Installation Instructions

Original Instructions

Back EMF Monitoring Relay Module

Catalog Numbers 440R-S35011, 440R-S35012, 440R-S35013,440R-S35014, 440R-S35015, 440R-S35016

Description

The Allen-Bradley Guardmaster® MSR55P back EMF modules are 

suitable to monitor the standstill of all electric motors that generate a 

remanence voltage while coasting to stop.
The MSR55P standstill module is connected to the motor terminals 

and measures the induced back EMF voltage. Two redundant measuring 

channels are used (L2-L1 and L3-L1). If the back EMF voltage drops to 

0V simultaneously in both channels, it indicates standstill and the 

output relay is energized.
The voltage threshold that indicates a standstill on the MSR55P 

module is adjustable. This standstill allows the unit to work with 

different types of motors in various applications. The standstill time T

(time delay between detection and energizing of the relay) is also 

adjustable.
The MSR55P standstill module detects a broken wire on the measuring 

inputs L1/L2/L3. If a broken wire is detected, the relay outputs go into 

safe state (as with running motor).

Features

• Safe standstill detection on three-phase and single-phase motors
• Performance Level is PLe
• Category 4 to EN ISO13849-1: 2008
• Safety integrity level (SIL) 3 to IEC/EN 61508
• SIL Claim Limit (SIL CL) 3 to IEC/EN 62061
• No external sensors necessary
• Standstill detection independent of direction
• Broken wire detection
• Three N.O. redundant voltage-free safety contacts and one 

redundant N.C. monitoring contact for up to 250V AC

• Two semiconductor status outputs
• Monitors motor voltage up to 690V AC
• Adjustable voltage setting
•  Adjustable standstill time delay
•  LED indicators for standstill, event of line breakage and 

operation voltage

• Suitable for operation with inverters
• Removable screw terminals

Figure 1 - Overview of Key Features

DIN Rail Mounting and Removal

MSR55P standstill module safety relays mount onto 35 mm (1.4 in.) 

DIN rails.

Spacing

MSR55P standstill module safety relays can be mounted directly next to 

other MSR and GSR safety relays.
Maintain a space of 50.8 mm (2 in.) above, below, and in front of the 

relay for adequate ventilation or provide forced (fan) cooling.

Removable Terminals

MSR55P standstill module safety relays have removable terminals to 

ease wiring and replacement.

IMPORTANT

Save these instructions for future use.

1. Insert the tip of a small 

screwdriver into the 

slot near the terminal 

screws.

2. To unlock the terminal 

block, rotate the 

screwdriver.

Three indicators 

for status and 

diagnostics

Removable terminal 

blocks

Standstill voltage setting

Standstill time delay setting

Отзывы: