4
Rockwell Automation Publication 1756-IN620D-EN-P - October 2018
ControlLogix Redundant Power Supply
European Hazardous Location Approval
The following applies to products marked
,
, II 3, such modules:
• Are Equipment Group II, Equipment Category 3, and comply with the Essential Health and Safety Requirements relating to the design and construction of such equipment given in Annex II to
Directive 94/9/EC. See the EC Declaration of Conformity at
rok.auto/certifications
for details. The type of protection for the 1756-PB75R, 1756-PBXTR, 1756-PSCA2, and 1756-PSCA2XT is “Ex nA IIC T4
Gc” according to EN 60079-15.
• May have Catalog numbers followed by a “K” to indicate a conformal coating option.
• Are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air are unlikely to occur, or are likely to occur only infrequently and for short periods. Such locations
correspond to Zone 2 classification according to ATEX directive 1999/92/EC.
• As the 1756-PB75R, 1756-PBXTR, 1756-PSCA2, and 1756-PSCA2XT comply to Standards: EN 60079-0:2012+A11:2013, EN 60079-15:2010, reference certificate number DEMKO13ATEX1325026X.
WARNING:
Special Conditions for Safe Use
• This equipment shall be mounted in an ATEX/IECEx Zone 2 certified enclosure with a minimum ingress protection rating of at least IP54 (as defined in EN/IEC
60529) and used in an environment of not more than Pollution Degree 2 (as defined in EN/IEC 60664-1) when applied in Zone 2 environments. The enclosure
must be accessible only by the use of a tool.
• This equipment shall be used within its specified ratings defined by Rockwell Automation.
• Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this
product.
• Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous.
• Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140% of the rated voltage when applied in
Zone 2 environments.
• This equipment must be used only with ATEX/IECEx certified Rockwell Automation backplanes.
• The instructions in the user manual shall be observed.
IEC Hazardous Location Approval
The following applies to products with IECEx Certification.
• Such modules are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air are unlikely to occur, or are likely to occur only infrequently and for short periods.
Such locations correspond to Zone 2 classification to IEC 60079-0.
• The type of protection for the 1756-PB75R, 1756-PBXTR, 1756-PSCA2, and 1756-PSCA2XT is “Ex nA IIC T4 Gc” according to IEC 60079-15.
• Such modules as the 1756-PB75R, 1756-PBXTR, 1756-PSCA2, and 1756-PSCA2XT comply to Standards IEC 60079-0:2011, IEC 60079-15:2010, reference IECEx certificate number IECExUL14.0008X.
• Such modules may have catalog numbers followed by a “K” to indicate a conformal coating option.
ATEX and IECEx Hazardous Location Conformity
Model
Protection Type
ATEX Certificate
IECEx Certificate
1756-PSCA2
Ex nA IIC T4 Gc
DEMKO13ATEX1325026X
IECEx UL 14.0008X
1756-PSCA2XT
Ex nA IIC T4 Gc
DEMKO13ATEX1325026X
IECEx UL 14.0008X
1756-PAXTR
None
—
—
1756-PBXTR
Ex nA IIC T4 Gc
DEMKO13ATEX1325026X
IECEx UL 14.0008X
1756-PA75R
None
—
—
1756-PB75R
Ex nA IIC T4 Gc
DEMKO13ATEX1325026X
IECEx UL 14.0008X
Prevent Electrostatic Discharge
ATTENTION:
This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when
you handle this equipment:
• Touch a grounded object to discharge potential static.
• Wear an approved grounding wrist strap.
• Do not touch connectors or pins on component boards.
• Do not touch circuit components inside the equipment.
• Use a static-safe workstation, if available.
• Store the equipment in appropriate static-safe packaging when not in use.