Allen-Bradley ControlLogix ControlNet 1756-CN2 Скачать руководство пользователя страница 31

ControlLogix ControlNet Interface Module    

31

Publication

  1756-IN607A-EN-P - February 2008

Specifications              

ControlLogix ControlNet Bridge Module - 1756-CN2, 1756-CN2R, Series B

Attribute

Value

Connectors

1756-CN2

 

1756-CN2R

 

1 - ControlNet BNC

 

2 - ControlNet BNC

USB port

USB 1.1

 

USB Device

 

USB Series B Receptacle

Recommended USB cable for USB 
port

Samtec cable, P/N RSP-199350

ControlNet communication rate

5 MB

Weight, approx.

1756-CN2

 

1756-CN2R

 

0.260 kg (0.57 lb)

 

0.293 kg (0.64 lb)

North American temperature code

T4A

IEC temperature code

T4

Number of nodes, max

99

Slot width

1

Connections supported, max

131

 

Note that 3 of the 131 connections are always 
reserved for redundant control. Therefore, 128 
connections are available for standard use.

Enclosure type rating

None (open-style)

Содержание ControlLogix ControlNet 1756-CN2

Страница 1: ...gin 8 Parts List 8 Identify Module Features 9 Set the Module s Network Address Switches 10 Reset the Module to the Original Factory Settings 10 Keeper Configuration Automatic Keeper Crossload 11 Prepa...

Страница 2: ...installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect...

Страница 3: ...tegory 3 equipment intended for use in potentially explosive atmospheres given in Annex II to this Directive Compliance with the Essential Health and Safety Requirements has been assured by compliance...

Страница 4: ...re le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature global du syst me Les combinaisons d quipements dans le syst me sont sujettes inspectio...

Страница 5: ...e must have suitable flame retardant properties to prevent or minimize the spread of flame complying with a flame spread rating of 5VA V2 V1 V0 or equivalent if non metallic The interior of the enclos...

Страница 6: ...rs The chassis that performs active control is called the primary chassis and the modules in the chassis are called primary modules The other chassis is called the secondary chassis and the modules in...

Страница 7: ...hassis Pair Remote I O Chassis 1756 RM Module ControlNet Network 1756 CNB CNBR 1756 CN2 Module 1756 CN2R Module 1756 CN2R Module 1756 CN2R Module 1756 RM Module The 1756 CN2 and 1756 CN2R series B mod...

Страница 8: ...CN2 or 1756 CN2R Module 1756 A4 1756 A7 1756 A10 1756 A13 or 1756 A17 Chassis 1756 PA72 1756 PA75 1756 PB72 or 1756 PB75 Power Supply 1786 TPR 1786 TPS 1786 TPYR or 1786 TPYS Taps 1 USB Cable optiona...

Страница 9: ...es B bridge modules Module Status Indicator Channel A BNC Connector COAX 00 Factory Reset on Power Up Invalid Network Address 01 99 Normal Operation Valid Network Address Backplane Connector Front Vie...

Страница 10: ...of 01 99 for modules in a standalone chassis Address 00 is an invalid ControlNet address Reset the Module to the Original Factory Settings To reset the module to its original settings and clear all ke...

Страница 11: ...the keeper capable nodes on the network it becomes the Master Keeper The Master Keeper is the node that distributes network configuration information to other nodes as the network is formed or as nod...

Страница 12: ...tible with all versions of chassis and power supplies Determine Module Slot Location Slot 0 is the first slot and is always the leftmost slot in the rack the first slot to the right of the power suppl...

Страница 13: ...e into the chassis Make sure the module backplane connector properly connects to the chassis backplane Do not force the module into the backplane connector If you cannot seat the module with firm pres...

Страница 14: ...CN2R Module in 1756 A4 chassis ControlNet Node ControlNet Link ControlNet Node Redundant Media optional For network connections we recommend taps with a straight connector catalog number 1786 TPS or...

Страница 15: ...raight or right angle connector to prevent the connector from accidentally contacting a metallic grounded surface Segment 1 Segment 2 Dust Cap Dust Cap 1756 CN2 Segment 1 1756 CN2R Segments 1 and 2 2...

Страница 16: ...oubleshooting To use modules in a redundant control chassis pair you must connect the primary and redundant partner modules to the same network segment If you are using redundant media connect the cha...

Страница 17: ...o Yes TEST No Yes Module status indicator red Self test has failed and the module displays an error message See pages 23 29 Replace the module Self test is complete The status indicator flashes green...

Страница 18: ...ntrolNet address in the same slot Install or Remove the Module Under Power You can install or remove the module while chassis power is applied if you take these precautions IMPORTANT WARNING When you...

Страница 19: ...e for your module from within RSLinx software by following the steps listed below 1 Open RSLinx software and browse for the module 2 Right click the module and select Upload EDS file from device The U...

Страница 20: ...ontain hubs The USB port is intended for temporary local programming purposes only and not intended for permanent connection If you connect or disconnect the USB cable with power applied to this modul...

Страница 21: ...module s USB port The Found New Hardware Wizard dialog appears 2 Click Install the software automatically Recommended and click Next The software is installed 3 Click Finish to set up your USB driver...

Страница 22: ...7A EN P February 2008 Status Indicators Module 1756 CN2R Module COAX B A OK B A COAX A OK A 1756 CN2 Module Status Display See page 23 Module Status LED Indicator See page 23 ControlNet Channel Status...

Страница 23: ...onnectors 3 Make sure the module is firmly seated in the chassis 4 If the indicator remains off replace the module Red Reset Complete Change Switch Settings Module s network address is set to 00 an in...

Страница 24: ...hassis that does not contain a 1756 SRM or 1756 RM module 2 Update the module s firmware using ControlFLASH Flashing red Image update Needed Boot image running Main firmware image needs to be updated...

Страница 25: ...1 The secondary module is disqualified with no partner Check the corresponding slot of the primary chassis for the module type and revision PwDS 1 The module is primary with a disqualified secondary p...

Страница 26: ...ashing green OK This is normal operation No connections to or through the module exist No action is required Invalid Network Configuration ControlNet configuration error Recheck configuration Verify t...

Страница 27: ...ule See Reset the Module to the Original Factory Settings on page 10 Keeper Unconfigured slot changed After the keeper object s network configuration data was downloaded the module was moved to a diff...

Страница 28: ...e Module to the Original Factory Settings on page 10 Keeper None Valid on Network The network configuration data maintained in flash memory by the keeper object does not match the current network conf...

Страница 29: ...required Alternating red off Node has been configured incorrectly Check network address and other ControlNet configuration parameters The ControlNet channel status indicators appear in one of these s...

Страница 30: ...nager node keeper is present and working and the selected address is not greater than the maximum unscheduled node address UMAX 1 The configuration manager node keeper is the node responsible for dist...

Страница 31: ...eries B Receptacle Recommended USB cable for USB port Samtec cable P N RSP 199350 ControlNet communication rate 5 MB Weight approx 1756 CN2 1756 CN2R 0 260 kg 0 57 lb 0 293 kg 0 64 lb North American t...

Страница 32: ...756 CN2R 1 1 A 5 1V dc 1 3 A 5 1V dc 3 mA 24V dc 3 mA 24V dc Isolation voltage 30V continuous Basic insulation type Tested to 500V ac for 60 s ControlNet network to system Wiring category 1 2 on commu...

Страница 33: ...rating IEC 60068 2 27 Test Ea Unpackaged Shock 30 g Shock nonoperating IEC 60068 2 27 Test Ea Unpackaged Shock 50 g Emissions CISPR 11 Group 1 Class A ESD immunity IEC 61000 4 2 6 kV contact discharge...

Страница 34: ...54689C CSA Certified Process Control Equipment for Class I Division 2 Group A B C D Hazardous Locations See CSA File LR69960C FM FM Approved Equipment for use in Class I Division 2 Group A B C D Hazar...

Страница 35: ...on Instructions publication 1756 IN078 Contains information on how to install ControlLogix power supplies 1756 PA72 and 1756 BP72 ControlLogix Power Supplies Installation Instructions publication 1756...

Страница 36: ...ng New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not f...