Allen-Bradley ControlLogix 1756-IF6I Скачать руководство пользователя страница 4

4

    ControlLogix Analog (10V) Output Module 

Publication 1756-IN035C-EN-P - October 2000

Understand Compliance to European Union Directive

If this product bears the CE marking, it is approved for installation 
within the European Union and EEA regions. It has been designed 
and tested to meet the following directives.

EMC Directive

This product is tested to meet Council Directive 89/336/EEC 
Electromagnetic Compatibility (EMC) and the following standards, in 
whole or in part, documented in a technical construction file:

EN 50081-2 EMC - Generic Emission Standard, Part 2 - 
Industrial Environment

EN 50082-2 EMC - Generic Immunity Standard, Part 2 - 
Industrial Environment

This product is intended for use in an industrial environment.

Low Voltage Directive

This product is tested to meet Council Directive 73/23/EEC Low 
Voltage, by applying the safety requirements of EN 61131-2 
Programmable Controllers, Part 2 - Equipment Requirements and 
Tests.

For specific information required by EN 61131-2, see the appropriate 
sections in this publication, as well as the following Allen-Bradley 
publications:

Industrial Automation Wiring and Grounding Guidelines, 
publication 1770-4.1

Automation Systems Catalog, publication B111

This equipment is classified as open equipment and must be installed 
(mounted) in an enclosure during operation as a means of providing 
safety protection.

Содержание ControlLogix 1756-IF6I

Страница 1: ...e com and placing an order To See page Obtain a User Manual 1 Identify the Module Components 2 Prevent Electrostatic Discharge 3 See Removal and Insertion Under Power RIUP 3 Understand Compliance to E...

Страница 2: ...assis and uses a separately ordered RTB or a Bulletin 1492 Interface Module IFM to connect all field side wiring This module uses one of the following RTBs 1756 TBNH 20 position NEMA RTB 1756 TBSH 20...

Страница 3: ...ou can remove and insert it under backplane power and field side power When you remove or insert a module while field side power is applied you may cause an electrical arc An electrical arc can cause...

Страница 4: ...ironment EN 50082 2 EMC Generic Immunity Standard Part 2 Industrial Environment This product is intended for use in an industrial environment Low Voltage Directive This product is tested to meet Counc...

Страница 5: ...ent overloading the power supply Install the Module You can install or remove the module while chassis power is applied ATTENTION The module is designed to support Removal and Insertion Under Power RI...

Страница 6: ...Wire the RTB with a 5 16 inch 8mm maximum flat bladed screwdriver before installing it onto the module Shielded cable is required when using this module We recommend using Belden 8761 cable to wire th...

Страница 7: ...tach aground lug and apply heat shrink tubing to the exit area 20104 M 20918 M E Connect the drain wire to a chassis mounting tab Use any chassis mounting tab that is designated as a functional signal...

Страница 8: ...ting field side wiring secure the wires in the strain relief area with a cable tie 20967 M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Shield Ground 1756 OF6VI OUT 1 Not used RTN 1 OUT 3 RTN 3...

Страница 9: ...injury or property damage because it may send an erroneous signal to your system s field devices causing unintended machine motion or loss of process control cause an explosion in a hazardous environm...

Страница 10: ...into place on the RTB the RTB housing door is closed the locking tab at the top of the module is unlocked 20853 M 20854 M Module guide RTB guides Locking tab 1 Align the side and top bottom RTB guide...

Страница 11: ...ion of the module Use the information below to remove the module LED indicators This display Means Take this action OK Steady green light The outputs are in a normal operating state None OK Flashing g...

Страница 12: ...IUP However when you remove or insert an RTB with field side power applied unintended machine motion or loss of process control can occur Exercise extreme caution when using this feature It is recomme...

Страница 13: ...None Output Overvoltage Protection 24V ac dc maximum Output Short Circuit Protection Electronically current limited Drive Capability 1000 loads 10mA maximum Output Settling Time 2ms to 95 of final val...

Страница 14: ...ined Field Wiring Arm and Housing 20 Position RTB 1756 TBNH or TBSH 1 Environmental Conditions Operating Temperature Storage Temperature Relative Humidity 0 to 60 C 32 to 140 F 40 to 85 C 40 to 185 F...

Страница 15: ...o help determine the overall temperature code of the system Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation...

Страница 16: ...de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature global du syst me Les combinaisons d quipements dans le syst me sont sujettes inspection par les autorit s locales...

Отзывы: