Allen-Bradley ControlLogix 1756-ENET/B Скачать руководство пользователя страница 2

2

    ControlLogix Ethernet Communication Interface Module 

Publication

 1756-IN053D-EN-P - June 2002

Important User Information

Because of the variety of uses for the products described in this 
publication, those responsible for the application and use of these 
products must satisfy themselves that all necessary steps have been 
taken to assure that each application and use meets all performance 
and safety requirements, including any applicable laws, regulations, 
codes and standards.  In no event will Rockwell Automation be 
responsible or liable for indirect or consequential damage resulting 
from the use or application of these products.

Any illustrations, charts, sample programs, and layout examples 
shown in this publication are intended solely for purposes of 
example. Since there are many variables and requirements associated 
with any particular installation, Rockwell Automation does not 
assume responsibility or liability (to include intellectual property 
liability) for actual use based upon the examples shown in this 
publication.

Allen-Bradley publication SGI-1.1, 

Safety Guidelines for the 

Application, Installation and Maintenance of Solid-State Control 

(available from your local Rockwell Automation office), describes 
some important differences between solid-state equipment and 
electromechanical devices that should be taken into consideration 
when applying products such as those described in this publication.

Reproduction of the contents of this copyrighted publication, in 
whole or part, without written permission of Rockwell Automation, is 
prohibited.

Throughout this publication, notes may be used to make you aware 
of safety considerations. The following annotations and their 
accompanying statements help you to identify a potential hazard, 

Содержание ControlLogix 1756-ENET/B

Страница 1: ...2 Identifying Module Components 6 Preparing the Chassis for Module Installation 6 Determining Module Slot Location 7 Installing the Module in the Chassis 8 Removing or Replacing the Module when appli...

Страница 2: ...here are many variables and requirements associated with any particular installation Rockwell Automation does not assume responsibility or liability to include intellectual property liability for actu...

Страница 3: ...practices or circumstances that can cause an explosion in a hazardous environment which may lead to personal injury or death property damage or economic loss ATTENTION Identifies information about pra...

Страница 4: ...y designed to prevent personal injury resulting from accessibility to live parts The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may...

Страница 5: ...to this Directive The examination and test results are recorded in confidential report No 28 682 010 Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN...

Страница 6: ...le Preparing the Chassis for Module Installation Before you install the Ethernet module you must install and connect a ControlLogix chassis and power supply www ETHERNET OK TXD RXD AUI 10 BASET 1756 E...

Страница 7: ...an also install multiple ENET modules in the same chassis The figure below shows chassis slot numbering in a 4 slot chassis Slot 0 is the first slot and is always the leftmost slot in the rack the fir...

Страница 8: ...n the Chassis Align the circuit board with top and bottom guides in the chassis 1 Slide the module into the chassis Make sure the module backplane connector properly connects to the chassis backplane...

Страница 9: ...ng or Replacing the Module when applicable IMPORTANT If you are replacing an existing module with an identical one and you want to resume identical system operation you must install the new module in...

Страница 10: ...rmation see the EtherNet IP Performance and Application Guide publication ENET IN001 Wire the appropriate connector according to this illustration WARNING When you insert or remove the module while ba...

Страница 11: ...or RJ45 connector to the matching Ethernet port WARNING If you connect or disconnect the Ethernet cable with power applied to this module or any device on the network an electrical arc can occur This...

Страница 12: ...es available in two lengths 2 meters catalog number 1756 TC02 or 15 meters catalog number 1756 TC15 Applying Chassis Power IMPORTANT Connecting the module to the network via an Ethernet switch will re...

Страница 13: ...e LED indicators to determine if the power supply and module are operating properly If the Power Supply and OK indicators are not in the states described above refer to the following troubleshooting s...

Страница 14: ...ur ControlLogix Ethernet Communication Interface Module User Manual publication 1756 UM051 If the OK indicator is then module status is take this action Off Not operating Apply chassis power Verify mo...

Страница 15: ...ature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature global du syst me Les combinaisons d quipements dans le syst me sont sujettes inspec...

Страница 16: ...C 60068 2 14 Test Na Un packaged Non operating Thermal Shock 40 to 85 C 40 to 185 F Relative Humidity IEC 60068 2 30 Test Db Un packaged Non operating Damp Heat 5 to 95 non condensing Shock IEC 60068...

Страница 17: ...compliant with EN 50082 2 Industrial Immunity EN 61326 Meas Control Lab Industrial Requirements EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions C Tick 2 Australian Radiocommunicati...

Страница 18: ...UV radiation The secondary of a current transformer shall not be open circuited when applied in Class I Zone 2 environments Equipment of lesser Enclosure Type Rating must be installed in an enclosure...

Страница 19: ...ControlLogix Ethernet Communication Interface Module 19 Publication 1756 IN053D EN P June 2002...

Страница 20: ...Publication 1756 IN053D EN P June 2002 PN 957689 13 Supersedes Publication 1756 IN053C EN P May 2001 Copyright 2002 Rockwell Automation Inc All rights reserved Printed in the U S A...

Отзывы: