Bulletin 900-CONV

Interface Converter

24

Specifications, Continued/Approximate Dimensions

Specifications, Continued

General/Environmental Ratings

Insulation Resistance

20 M

Ω

min. measured at 500V DC between the following:

External terminals 

casing

RS-232C terminals 

RS-485 terminals power supply terminals

Isolation Method

Communications

Phototransistor coupler

Power supply

Isolating transformer

Dielectric Strength

1,500 V AC for 1 min. between the external terminal and case, and between the RS-232C
RS-485 block power supply terminal

Noise Immunity

500 V AC for 1 min. between the RS-232C/USB block and RS-485 block

Vibration (Max.)

10…55 Hz, 0.5 mm single amplitude for 10 min. each in X, Y, and Z directions (1 G)

Shock (Max.)

98 m/s

2

(10 G), 3 times each in X, Y, and Z directions

Weight

Approx. 150 g

Enclosure Rating

Front Panel Operation Parts

Conforms to IEC standards, equivalent to IP20 (when terminal cover mounted) 

Terminals

Equivalent to VDE 0106/100 (when terminal cover mounted) 

Memory Protection

No protective functions (communications data is not protected for power interruptions
during communications)

EMC

Radiated Emission

EN61326 class A

Conducted Emission

EN61326 class A

Immunity ESD

EN61000-4-2: 4 kV contact discharge (level 2); 8 kV air discharge (level 3)

Immunity RF-Interference

EN61000-4-3: 10V/m (amplitude modulated, 80 MHz…1 GHz) (level 3)
10V/m (pulse modulated, 900 MHz)

Immunity Conducted Disturbance

EN61000-4-6: 10V (0.15…80 MHz) (level 3)

Immunity Burst

EN61000-4-3: 2 kV power-line (level 3); 2 kV I/O signal-line (level 4)

Conformity to Standards

UL508, CSA C22.2 No. 14-95
Conforms to EN50081-2, EN50082-2, EN61010-1 (IEC 61010-1)
Conforms to VDE 0106/part 100 (Finger Protection), when the terminal cover is mounted.

When USB communication is used, the cover must be removed

Approximate Dimensions

Approximate dimensions are shown in millimeters unless otherwise indicated (to convert to inches, multiply by 0.0394). Dimensions are not to
be used for manufacturing purposes.

Cat. No. 900-CONVZ25

 

Содержание Bulletin 900-CONV

Страница 1: ...SELECTION GUIDE BULLETIN 900 TC Single Loop Electronic Temperature Process Controllers...

Страница 2: ......

Страница 3: ...series A controllers MV Manipulated Variable Display Yes No PF Key addition to keypad allows one touch assignment of Auto Manual Run Stop etc Yes No Thermocouple Types Added W and PL II Yes Yes Thermo...

Страница 4: ...x Heating Cooling Control Mode Yes Yes Yes Control Method ON OFF or 2 PID auto tune and self tune with time proportioning ON OFF outputs or Analog Output 900 TC8 900 TC16 Inputs Thermocouple Input and...

Страница 5: ...tput Type Supports Heater Burnout Open and Heater Short Circuit Alarm Controller Cat No 900 TC16 97 1 16 DIN 48 mm W x 48 mm H x 78 mm D Thermocouple or RTD 100 240V AC 2 Relay Output Yes 900 TC16RGTU...

Страница 6: ...8COM B Event Input Unit Event inputa 900 TC8EIM 900 TC16 Communications and 1 Phase Heater Burnout Unit and Heater Short RS 485 communications with single phase heater burnout open and heater short ci...

Страница 7: ...lder Personal Computer Configuration Software for Bulletin 900 TC32 Temperature Controllers available in CD format only 900 BLDSW1 Current Transformer Use with Bulletins 900 TC8 and 900 TC16 Only for...

Страница 8: ...alfunction y After connecting the Conversion Cable to the computer check the COM port number before starting communications The computer requires time to recognize the cable connection This delay does...

Страница 9: ...TC16 Bulletin 900 TC32 SUB SUB or Amber 6 MANU Manual Mode Lights when the controller mode is in manual 7 Key Lights when thesettings change protection is ON Keys disabled failure open or short A SUB...

Страница 10: ...100 0 200 0 2300 Usable in the following ranges by scaling 1999 to 9999 or 199 9 to 999 9 1800 1700 1700 0 0 3 1 0 0 3 1 0 0 3 1 0 5 8 0 5 8 0 5 8 600 500 0 500 0 500 0 400 0 400 400 0 400 400 0 260...

Страница 11: ...Cu CuNi DIN 43710 1985 7 JPt100 JIS C1604 1989 JIS C1606 1989 Pt100 JIS C1604 1997 IEC 751 The non contact temperature sensor must be configurable for type K thermocouple output within either of the...

Страница 12: ...TC8 900 TC16 SPST NO 250V AC 3 A 30V DC 5 A max resistive load electrical life 100 000 operations min load 1V 1 mA 900 TC32 SPST NO 250V AC 1 A 30V DC 2 A max resistive load electrical life 100 000 o...

Страница 13: ...Conformed Standards General Environmental Ratings Conforms to EN61010 1 IEC 61010 1 and VDE 0106 part 100 finger protection when the terminal cover is installed Pollution Level 2 Overcurrent Category...

Страница 14: ...900 TC8 RS 232C or RS 485 2 wire half duplex 900 TC16 RS 485 2 wire half duplex 900 TC32 RS 485 2 wire half duplex Synchronization Method Start stop synchronization Protocol 900TC or Modbus RTU Slave...

Страница 15: ...units are mounted together make sure that the surrounding ambient temperature does not exceed the allowable operating temperature specification Safety Terminal Cover9 Bulletin 900 TC16 Panel Cutouts y...

Страница 16: ...it so that it is waterproof apply the waterproof gasket to the unit y When two or more units are mounted together make sure that the surrounding ambient temperature does not exceed the allowable opera...

Страница 17: ...tect the Bulletin 900 TC8 900 TC16 and its lines from external noise y Solderless lugs are recommended when wiring to the Bulletin 900 TC8 900 TC16 wire terminals However if lugs are not used the cont...

Страница 18: ...input terminals output terminals and communication terminals If reinforced insulation is required provide additional insulation such as spatial distance or material insulation as defined by IEC 60664...

Страница 19: ...quivalent cable provides the physical connection between the converter and the PC RS 485 allows linking up to 31 controllers with a single personal computer Series B provides baud rates up to 57 6 K b...

Страница 20: ...come in contact with the case 1 Insert the Bulletin 900 TC8 into the mounting hole in the panel from the front panel thickness 1 to 8 mm Ensure the waterproof gasket is in place if this is a UL Type 4...

Страница 21: ...tin 900 TC32 can quickly be replaced by removing the field terminal plate 1 Press in firmly on the fasteners at both sides of the terminals to unlock the terminal plate and pull it upwards 2 Remove th...

Страница 22: ...ion Guide Publication 700 SG003x EN P for additional information Bulletin 700 SX Controller Configuration from Keypad Controller configuration of parameters can be done using the four keys on the bott...

Страница 23: ...mm H x 78 mm D 100 240V AC 900 CONVZ25 24V AC DC 900 CONVU25 7 Converts personal computer RS 232 USB communications to RS 485 Use for interface with a single Bulletin 900 TCx or multiple up to 31 con...

Страница 24: ...t to IP20 when terminal cover mounted Terminals Equivalent to VDE 0106 100 when terminal cover mounted Memory Protection No protective functions communications data is not protected for power interrup...

Страница 25: ...switch is set to OFF 12 SDB Note Terminals 2 and 10 are not used Terminal Specifications Make sure to check the input and output specifications for the signal pins of connected devices before connecti...

Страница 26: ...le of Contents Product Selection 26 y 300 MHz CPU y 650 MB free disk space y SVGA resolution monitor XGA recommended y Microsoft Windows supported mouse y Available serial 9 pin COM port COM address 1...

Страница 27: ...y Microsoft Windows 95 y Microsoft Windows 98 y Microsoft Windows NT 4 0 service pack 6 y Microsoft Windows 2000 y Provides a Graphic Configuration Option to Using the Bulletin 900 TC32 Controller s...

Страница 28: ...Visit our website www ab com catalogs Bulletin 900 TC Single Loop Temperature Process Controller Notes 28...

Страница 29: ......

Страница 30: ...Publication900 SG001D EN P September 2008 Copyright 2008 Rockwell Automation Inc All Rights Reserved Printed in USA...

Отзывы: