Chapter 1
About the Switches
Hardware Features
See the following for a description of hardware features:
•
For Stratix 5400, Stratix 5700, ArmorStratix 5700, and Stratix 8000/
8300 switches, see
•
For Stratix 5410 switches, see
•
For supported SFP modules, see the Stratix Ethernet Device
Specifications Technical Data, publication
Table 2 - Hardware Features for Stratix 5400, Stratix 5700, ArmorStratix 5700, and Stratix 8000/8300 Switches
Feature
Description
Power and relay connectors
You connect the power and alarm signals to the front panel of a switch:
•
Stratix 5400 switches—One connector provides primary DC power. A second connector provides secondary power. The two connectors are
physically identical. You can activate alarms for environmental, power supply, and port status alarm conditions. You can configure an alarm
to indicate open or closed contacts. There is no separate power connector for PoE.
•
Stratix 5700 switches—One connector provides primary DC power and a second connector provides secondary power. The two connectors
are physically identical. You can activate alarms for environmental, power supply, and port status alarm conditions. You can configure an
alarm to indicate open or closed contacts. A separate power connector is required for PoE.
•
ArmorStratix 5700 switches—One cable provides DC power from one or dual power sources. Relay connectors and alarm relays are
available for only catalog numbers 1783-ZMS4T4E2TGP, 1783-ZMS8T8E2TGP, 1783-ZMS4T4E2TGN, and 1783-ZMS8T8E2TGN. There is no
separate power connector for PoE.
•
Stratix 8000/8300 switches—One connector provides primary DC power (supply A) and the major alarm signal. A second connector
provides secondary power (supply B) and the minor alarm signal. The two connectors are physically identical and are in the upper-left side
of the front panel.
The power and relay connectors also provide an interface for two independent alarm relays: the major alarm and the minor alarm. You can
activate the relays for environmental, power supply, and port status alarm conditions. You can configure an alarm to indicate open or closed
contacts. The relay itself is normally open, so under power failure conditions, the contacts are open. From the Command-line interface (CLI),
you can associate any alarm condition with one alarm relay or with both relays.
When dual power sources are operational for any of the switches, the switch draws power from the DC source with the higher voltage. If one of
the two power sources fail, the other continues to power the switch.
Console port
To configure, monitor, and manage a switch, you can connect a switch to a computer through the console port:
•
Stratix 5400 and Stratix 5700 switches—Connect to the console port with an RJ45-to-DB-9 adapter cable or a mini USB cable. The mini USB
driver is available in the firmware download section at
http://www.rockwellautomation.com
.
•
ArmorStratix 5700 switches— Connect to the console port with an M12-to-DB-9 cable. See
•
Stratix 8000/8300 switches—Connect to the console port with an RJ45-to-DB-9 adapter cable.
Dual-purpose (combo)
uplink ports
You can configure the dual-purpose uplink ports available on some models for RJ45 (copper) or SFP (fiber) media types. Only one of these
connections in each of the dual-purpose ports can be active at a time. If both ports are connected, the SFP module port has priority.
You can set the copper RJ45 ports to operate at 10 Mbps, 100 Mbps, or 1000 Mbps, full-duplex, or half-duplex. You can configure them as fixed
10 Mbps, 100 Mbps, or 1000 Mbps (Gigabit) Ethernet ports and can configure the duplex setting. 1000 Mbps is not supported on all modules
with combo ports.
You can use approved Gigabit (or 100 Mbps) Ethernet SFP modules to establish fiber-optic connections to other devices. These transceiver
modules are field-replaceable and provide the uplink interfaces when inserted into an SFP module slot. You use fiber-optic cables with LC
connectors to connect to a fiber-optic SFP module. These ports operate only in full-duplex.
10/100 copper ports
You can set the 10/100 copper ports to operate at 10 Mbps or 100 Mbps, full-duplex, or half-duplex. You can also set these ports for speed and
duplex autonegotiation in compliance with IEEE 802.3-2002. The default setting is autonegotiate.
When set for autonegotiation, the port senses the speed and duplex settings of the attached device. If the connected device also supports
autonegotiation, the switch port negotiates the connection with the fastest line speed that both devices support. The port also negotiates
full-duplex transmission if the attached device supports it. The port then configures itself accordingly. In all cases, the attached device must be
within 100 m (328 ft) of the switch.
Содержание armorstratix 5700
Страница 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Страница 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Страница 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Страница 148: ...148 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features ...
Страница 282: ...282 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features Notes ...
Страница 317: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 317 Monitor the Switch Chapter 4 ...
Страница 319: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 319 Monitor the Switch Chapter 4 ...
Страница 325: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 325 Monitor the Switch Chapter 4 ...
Страница 338: ...338 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 5 Troubleshoot the Switch Notes ...
Страница 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Страница 404: ...404 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix B Port Assignments for CIP Data Notes ...
Страница 450: ...450 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix D Cables and Connectors Notes ...
Страница 457: ......