144
Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011
Appendix B
CIP Information
Input Only Connection
This connection is used to read data from the module without controlling the
outputs. This connection is not dependent on any other connection.
It is recommended that the originator sets the data size in the O->T direction of
the Forward_Open be zero.
•
Number of supported input only connections equals two (shared with
exclusive owner and listen only connection).
•
Connection point O -> T shall be Assembly object, Instance 191 (Input
only heartbeat).
•
Connection point T -> O shall be Assembly object, Instance 52, 150, or
151 (150 for product codes <= 0x100 only, 151 for product codes > 0x100
only).
Listen Only Connection
This connection is dependent on another connection to exist. If that
connection(exclusive owner or input only) is closed, the listen only connection
shall be closed as well.
It is recommended that the originator sets the data size in the Forward_Open be
zero.
•
Number of supported listen only connections equals two (shared with
exclusive owner and listen only connection).
•
Connection point O -> T shall be Assembly object, Instance 192 (Listen
only heartbeat)
•
Connection point T -> O shall be Assembly object, Instance 52, 150 or
151 (150 for product codes <= 0x100 only, 151 for product codes > 0x100
only)
Class 3 Connections
Class 3 connections are used to establish connections to the message router. The
connection is used for explicit messaging. Class 3 connections use TCP
connections.
•
Three concurrent encapsulation sessions will be supported
•
Six concurrent Class 3 connections will be supported
•
More than one Class 3 connection per encapsulation session will be
supported
•
Supported API: 100…10000 ms
•
T->O Connection type: point-to-point
•
O->T Connection type: point-to-point
•
Supported trigger type: application
IMPORTANT
If an exclusive owner connection has been opened against the module
and times out, the input only connection shall time-out as well. If the
exclusive owner connection is properly closed, the input only connection
shall not be affected.
Содержание 56RF
Страница 1: ...RFID Systems Bulletin Number 56RF User Manual...
Страница 6: ...6 Rockwell Automation Publication 56RF UM001A EN P October 2011 Table of Contents Notes...
Страница 12: ...12 Rockwell Automation Publication 56RF UM001A EN P October 2011 Chapter 1 Introduction Notes...
Страница 34: ...34 Rockwell Automation Publication 56RF UM001A EN P October 2011 Chapter 3 Electrical Installation Notes...
Страница 48: ...48 Rockwell Automation Publication 56RF UM001A EN P October 2011 Chapter 5 Mechanical Installation Notes...
Страница 112: ...112 Rockwell Automation Publication 56RF UM001A EN P October 2011 Chapter 10 SLC Code Examples Notes...
Страница 118: ...118 Rockwell Automation Publication 56RF UM001A EN P October 2011 Chapter 11 MicroLogix 1400 Code Examples Notes...
Страница 148: ...148 Rockwell Automation Publication 56RF UM001A EN P October 2011 Appendix B CIP Information Notes...
Страница 152: ...152 Rockwell Automation Publication 56RF UM001A EN P October 2011 Appendix C Install the AOP Add On Profile Notes...
Страница 155: ......