Allen-Bradley 42KD Скачать руководство пользователя страница 3

Rockwell Automation 42KD-IN001A-EN-P — October 2014

42KD Miniature Sensor     3

Standard Teach:

1. To teach the background (first condition):

2. Teach “target” (second condition):

If there’s no background surface in the field of view in Step 1, the 
switching threshold will be set between the distance to the target and 
the maximum sensing range. The sensor can also be taught by 
teaching the target as the first condition and background as the 
second condition.

Precision Teach: For a more precise setting with a smaller hysteresis, 
teach the sensor to the target in step 1 and keep the target present in 
step 2).

Restore to factory default setting of maximum range: Perform 
steps 1 and 2 with “no target” in the sensor’s field of view and nothing 
in the background.

Teach Light Operate (L.O.) or Dark Operate (D.O.)

The default setting of the output is dark operate (D.O.)

L.O. setting means that output turns ON when the target is detected. If 
the application requires the output to turn OFF when the target is 
detected, the setting may be changed to dark operate (D.O.).

1. To access the teach output mode setting:

Align the sensor to the background. Press and 
hold button for three seconds until yellow LED 
starts flashing. Release the button. The first 
condition has now been taught.

In the case of multiple reflectivity targets, 
choose the darkest/least reflective target 
placed in its farthest position for set up.

Insert the target between the sensor and the 
background. Press and release the button. The 
teach process is complete. 

If the push button is not pressed within 30 
seconds, the sensor exits teach mode and returns 
to RUN mode without learning the new setting.

Press and hold button for six seconds until the 
green LED starts flashing. Release the button. The 
current setting is indicated by the yellow LED:
L.O.: Yellow LED ON
D.O.: Yellow LED OFF

t > 3 s

Background

t > 3 s

IMPORTANT

Target

Background

t < 0.5 s

t > 6 s

2. To change the sensor output mode setting:

Output Type Selection: Auto PNP/NPN, Dedicated NPN, 
Dedicated PNP

The default setting is Auto PNP/NPN. The sensor monitors the load 
connection and automatically configures for proper operation, i.e. 
PNP or NPN. If no load is connected, the sensor defaults to PNP. The 
following applications are covered with dedicated PNP or dedicated 
NPN selection:

a. Parallel wiring of multiple sensor outputs: select dedicated PNP 

or dedicated NPN setting, as needed.

b. If the load is connected for NPN configuration but to a power 

supply other than that to the sensor or via a load enabling 
contact (e.g. a relay contact in series with the load), select 
dedicated NPN.

Selection can be made as follows:

1. To access output type: Press and hold the push button for nine 

seconds (until both LEDs start flashing synchronously). Upon 
button release, the current setting of output type is indicated by 
the slow flashing of the LED(s) as follows:

• Auto PNP/NPN: both LEDs flashing
• Dedicated NPN: green LED flashing
• Dedicated PNP: yellow LED flashing

2. To change output type: Press and release the push button within 

10 seconds to select desired type. Each button activation cycles to 
the next output setting. The type selected is indicated by the LEDs. 
The sensor retains the setting per the last button depression and 
returns to the RUN mode 10 seconds after the last button is 
pressed.

Push Button Lock/Unlock

The push button or remote teach (RT) can be used to prevent 
unauthorized users from changing teach settings.

To lock the push button: press and release the button three times 
within three seconds. Both LEDs flash synchronously for three seconds 
indicating that the push button is now locked.

To unlock the push button: press and release the button three times 
within three seconds. Both LEDs flash asynchronously for three 
seconds indicating that the push button is now unlocked.

Permanent Lock: The push button may be permanently locked by 
connecting the white wire (pin 2) to –V.

Remote Teach (RT)

The sensor can be taught remotely via the white wire (pin 2). 
Connection to +V acts the same as the button being pressed and no 
connection is the same as the button not being pressed. The sensor 
can be taught by following the same teach/timing sequence as used 
in the push button teach (e.g., connect to the +V for more than three 
seconds to teach the “target,” disconnect from the +V; remove the 

Press and release the button within ten seconds to 
toggle from L.O. to D.O., the selection indicated by 
the yellow LED.

The sensor retains the setting per the last button 
depression and returns to the RUN mode ten 
seconds after the last button is depressed.

t < 0.5 s