Wiring Requirements

Shield Clamp Installation

Factory-supplied 2090-Series single motor cables are shielded and the braided cable shield must terminate at the drive during installation. The exposed area must be clamped (with the clamp provided) at the bottom front of the drive. 
Clamp spacers, included with the dual-axis inverters and held captive by rivets, are not needed for Kinetix VP motor installations, and can be removed.

Dual-axis Inverter
Cat. No.

Description

Connects to Terminals

Wire Size 

(1)

mm 

2

 (AWG)

(1)

Wire size is expressed as a range where solid wire is at the low end of the range (smaller diameter) and stranded wire is at the high end (larger diameter). For example, 6 (solid)…25 (stranded) mm

2

 or 10 (solid)…4 (stranded) AWG.

Strip Length

mm (in.)

Torque Value

N•m (lb•in)

Pin

Signal

2198-D006-ERS

x

2198-D012-ERS

x

2198-D020-ERS

x

2198-D032-ERS

x

Motor power
(axis A and B)

Motor power cable depends on 
motor/drive combination.

0.75…2.5 

(2)

(18…14)

(2)

Building your own cables or using third-party cables for Kinetix VP motors is not an option. Use 2090-CS

x

M1DE/DG single motor cables. Refer to the Kinetix Motion Accessories Specifications Technical Data, publication 

KNX-TD004

, for cable specifications.

10.0 (0.39)

0.5…0.6
(4.4…5.3)

2198-D057-ERS

x

2.5…6 

(2)

(14…10)

10.0 (0.39)

0.5…0.8
(4.4…7.1)

2198-D

xxx

-ERS

x

PELV/SELV

24V power 
(connector plug)

CP-1
CP-2

24V+
24V–

0.5…2.5
(20…14)

7.0 (0.28)

0.22…0.25
(1.9…2.2)

Brake power
(axis A and B)

BC-1
BC-2

MBRK+
MBRK–

N/A 

(3)

(3)

Motor brake wires are included (when specified) in the Bulletin 2090 motor cable.

DC Bus power 

Bus bar

DC–
DC+

N/A 

(4)

(4)

Shared DC-bus power connections are always made from one drive to another over the bus-bar connection system. These terminals do not receive discrete wires.

N/A 

(4)

N/A 

(4)

Safety

ST0-1
ST0-2, STO-10
ST0-3, STO-11
ST0-4, STO-12
ST0-5, STO-13
ST0-6, STO-14
ST0-7, STO-15
ST0-8, STO-16
ST0-9

SB+
S1A
SCA
S2A
SB-
S1B
SCB
S2B
N/C

0.14…1.5
(26…16)

10.0 (0.39)

N/A 

(5)

(5)

This connector uses spring tension to hold wires in place.

Digital inputs

IOD-1
IOD-2
IOD-3
IOD-4
IOD-5
IOD-6
IOD-7
IOD-8
IOD-9
IOD-10

IN1
COM
IN2
COM
SHLD
IN3
COM
IN4
COM
SHLD

0.14…1.5
(26…16)

10.0 (0.39)

N/A 

(5)

U
V

W

U
V

W

D+

D-

D+

D-

MF-A

MF-B

Motor Cable
Shield Clamp

2198-KITCON-DSL

Motor Feedback Connector Kits

(supplied with 2090-CSBM1DE cables)

Motor Power (MP) and

Motor Brake (BC) Connectors

Exposed Shield Braid 

Under Clamp

2198-D

xxx

-ERS

x

Dual-axis Inverter,
(side view)

Clamp Bolt 
and Nut

Clamp Knob

(hand tighten)

This shield clamp example illustrates 2090-CSBM1DE/DG 

single motor cables that attach to Kinetix VP motors. 

For example illustrations of Bulletin 2090 cables that attach to 

MP-Series™ motors and actuators, refer to the Kinetix 5700 

Servo Drives User Manual, publication

 2198-UM002

.

2090-CSBM1DE-

xx

AA

xx

Single Motor Cables

Stress 
Relief

Rivets (2)

Clamp

Spacers (2)

Отзывы: