154
Rockwell Automation Publication 2099-UM001D-EN-P - December 2012
Appendix A
Specifications and Dimensions
Certifications
Environmental Specifications
Agency Certification
(1)
Standards
c-UL-us
(2)
UL Listed to U.S. and Canadian safety standards (UL 508C File E59272).
Solid-state motor overload protection provides dynamic fold-back of motor current when 110% of the motor rating is reached with a peak
current limit based on the peak rating of the motor as investigated by UL to comply with UL 508C (UL File E59272, volume 1, section 22).
CE
European Union 2004/108/EC EMC Directive compliant with:
•
EN 60034-1:2004: Rotating electrical machines - Part 1: Rating and performance
•
EN 61800-3:2004: Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods
European Union 2006/95/EC Low Voltage Directive compliant with:
•
EN 50178:1997 - Electronic equipment for use in power installations
Functional Safety
•
EN 60204-1:2006 - Safety of Machinery - Electrical equipment of machines - Part 1: General requirements
•
IEC 61508 Part 1-7:2000 - Functional safety of electrical/electronic/programmable electronic safety-related systems
•
EN ISO 13849-1:2008 - Safety of machinery. Safety-related parts of control systems - Part 1: General principles for design
C-Tick
•
Radiocommunications Act: 1992
•
Radiocommunications (Electromagnetic Compatibility) Standard: 1998
•
Radiocommunications (Compliance Labelling - Incidental Emissions) Notice: 1998
•
AS/NZS CISPR 11: 2002 (Group 2, Class A)
KC
Korean Registration of Broadcasting and Communications Equipment, compliant with:
•
Article 58-2 of Radio Waves Act, Clause 3
•
Registration Number: KCC-REM-RAA-2099
(1) When product is marked, refer to
www.rockwellautomation.com/products/certification/
for Declarations of Conformity Certificates.
(2) Underwriters Laboratories Inc. has not evaluated the safe-off, safe torque-off, or safe speed-monitoring options in these products.
Attribute
Operational Range
Storage Range (nonoperating)
Temperature, ambient
0…50
°
C (32…122
°
F)
-40…70
°
C (-40…158
°
F)
Relative humidity
5…95% noncondensing
5…95% noncondensing
Altitude
1000 m (3281 ft)
3000 m (9843 ft) with derating
3000 m (9843 ft) during transport
Vibration
5…55 Hz @ 0.35 mm (0.014 in.) double amplitude, continuous displacement; 55…500 Hz @ 2.0 g peak constant acceleration (10 sweeps in
each of 3 mutually perpendicular directions).
Shock
15 g, 11 ms half-sine pulse (3 pulses in each direction of 3 mutually perpendicular directions)