Publication 2098-IN003E-EN-P — April 2004
3-14
Connecting Your Ultra3000
Figure 3.14
TB1 Terminal Positions
Shunt Module Power Wiring Requirements
1
75° C (167° F), 600V copper wire. Maximum length 3.05 m (10 ft).
2
105° C (221° F), 600V copper wire (preferred) 90° C (194° F) (minimum). Maximum length 3.05 m (10 ft).
Note: Refer to Figure 3.15 for TB2 terminal positions.
TB1 Terminal Positions
(2098-DSD-005
x-xx
, -010
x-xx
,
-020
x-xx
)
TB1 Terminal Positions
(2098-DSD-030
x-xx
)
TB1 Terminal Positions
(2098-DSD-075
x-xx
and
-150
x-xx
)
TB1 Terminal Positions
(2098-DSD-HV
xxx-xx
and
-HV
xxx
X
-xx
)
Motor Power
Connections
Input Power
Connections
Active Shunt
Connections
DC Bus+
DC Bus-
L1
L2/N
U
V
W
U
V
W
DC Bus+
DC Bus-
L1
L2/N
L1 AUX
L2/N AUX
AC Input
Power
Connections
Motor Power
Connections
U
V
W
DC Bus+
DC Bus-
L1
L2
L3
L1 AUX
L2/N AUX
Motor Power
Connections
AC Input
Power
Connections
DC Bus+
DC Bus-
W
V
U
L3
L2
L1
L1 AUX
L2/N AUX
Motor Power
Connections
AC Input
Power
Connections
Ultra3000 Drives
Shunt Module
Catalog Number
Connects to
Terminals
Recommended
Wire Size
mm
2
(AWG)
Terminal Block
Torque Values
Nm (lb-in.)
2098-DSD-005
x-xx
, -010
x-xx
, and
-020
x-xx
2090-UCSR-A300
4.0 (12)
1
1.25 (11)
2098-DSD-030
x-xx
9101-1183
TB2-1
TB2-2
TB2-3
2.5 (14)
1
2098-DSD-075
x-xx
and
2098-DSD-150
x-xx
2090-UCSR-P900
10 (8)
1
2098-DSD-HV030
-xx
, -HV030X-
xx
-DSD-HV050
-xx
, and -HV050X-
xx
2090-SR120-09
6 (10)
2
2098-DSD-HV100
-xx
and
-HV100X-
xx
2090-SR040-09 or
2090-SR040-18
2098-DSD-HV150
-xx
and
-HV150X-
xx
2090-SR025-09 or
2090-SR025-18
2098-DSD-HV220
-xx
and
-HV220X-
xx
2090-SR020-36
TB1-DC Bus+
TB1-DC Bus-
TB1-L1
TB1-L2/N
Содержание 2098-DSD-005
Страница 4: ...II Rockwell Automation Publication 2098 IN003E EN P March 2012 Summary of Changes Notes...
Страница 128: ...Publication 2098 IN003E EN P April 2004 3 32 Connecting Your Ultra3000...
Страница 178: ...Publication 2098 IN003E EN P April 2004 B 24 Interconnect Diagrams...
Страница 193: ......