18
Fiber Optic Cable Installation and Handling Instructions
Publication 2090-IN010C-EN-P – April 2005
Configuring Light Source
Configure test module as test light source
1.
Plug module into ControlLogix rack
2.
Set desired light power. Switch up for hi power output. Switch down
for low power output.
Configure Ultra3000
TM
drive as test light source
1.
Set baudrate rotary switch to the 9:00 position to enable continuous
light output mode.
2.
Power up the drive
The drive is outputting in continuous light mode at maximum output power.
Configure Kinetix
TM
family drive as test light source
1.
Set DIP switch 1 to proper position to enable high power output.
(See drive user manual for proper position).
2.
Connect a computer to the Drive via a serial port and anaconda.
3.
Use drive explorer software to set IDN701 to a value of 91 to enable
continuous light output mode.
The drive remains in this mode until power is cycled.
Measurement using general purpose LED source.