Appendix B
Quickstart
3.
Configure the DeviceNet devices as shown below.
4.
Set the node address for the CompactBlock LDX through the node
switches to node 1.
5.
Set the node address for the PowerFlex drive through the 25-COMM-D to
node 2. Set the baud rate to autobaud.
Configuration
1.
Launch Connected Components Workbench and open the sample project
you have downloaded from the Sample Code Library.
2.
Import the following DNET UDFBs into your project:
•
RA_DNET_MASTER
•
RA_DNET_LDX_DISCRETE
•
RA_PF_DNET_STANDARD
See
User Defined Function Blocks on page 45
for information on input
and output parameters for these UDFBs.
WARNING:
Do not change the configuration when the Controller is in
RUN mode.
Esc
Sel
Micro800 controller
CompactBlock LDX
Component on
DeviceNet
Network
PowerFlex 523
with
25-COMM-D
COMM
power
supply
1
KwikLink Lite IP20 Flat Media
2
Trunk Line Connector
3
Drop Line Connector
4
Terminating Resistor
5
5-pin Open Style Connector
6
Power Tap with terminating resistor
46220
Содержание 2080-DNET20
Страница 8: ...viii Rockwell Automation Publication 2080 UM004C EN E March 2015 Table of Contents Notes ...
Страница 14: ...6 Rockwell Automation Publication 2080 UM004C EN E March 2015 Chapter 1 Micro800 Plug in Modules Notes ...
Страница 26: ...18 Rockwell Automation Publication 2080 UM004C EN E March 2015 Chapter 2 Install and Wire Your Module Notes ...
Страница 86: ...78 Rockwell Automation Publication 2080 UM004C EN E March 2015 Appendix A Specifications Notes ...
Страница 112: ...104 Rockwell Automation Publication 2080 UM004C EN E March 2015 Appendix B Quickstart Notes ...
Страница 117: ...Rockwell Automation Publication 2080 UM004C EN E March 2015 109 ...