4–12
Configuring the Scanner
Publication 2755-6.4
Decode Options
Beep After Good Decode
When enabled, the beeper sounds during scanning. We recommend
that you operate the unit with the beeper enabled. The default is
enabled.
The beeper always operates during parameter menu scanning and
indicates error conditions. See page 3–8 for beeper indications.
Beeper Tone
Sets the decode beep frequency or tone to low, medium or high. The
default is high.
Decode Buffering
When enabled, this option allows the scanner to store decoded data
until the host device is ready to receive them. If the scanner reaches
its capacity for storing decoded symbols before the host is ready,
subsequent triggers have no effect until the buffer is available. The
default is disabled.
Pause Duration
This parameter inserts a pause after a bar code is scanned to allow
time for the data to be decoded and transferred to the host. You can
set a pause duration in .1 (1/10) second intervals from 0.1 to 9.9
seconds. Pauses are set by scanning a two digit number. The default
is 0.0 seconds.
For example, to set a .5 (1/2) second delay, scan the following labels:
–
Pause Duration
–
0 (under Pause Duration)
–
5 (Under Pause Duration)