Electrical Safety Consideration 

 

ATTENTION: 

This product is grounded through the DIN rail to chassis ground. 

Use zinc plated yellow-chromate steel DIN rail to assure proper grounding. The 
use of other DIN rail materials (for example, aluminum or plastic) that can 
corrode, oxidize, or are poor conductors, can result in improper or intermittent 
grounding. Secure DIN rail to mounting surface approximately every 200 mm 
(7.8 in.) and use end-anchors appropriately. Be sure to ground the DIN rail 
properly. Refer to Industrial Automation Wiring and Grounding Guidelines, 
Rockwell Automation publication 

1770-4.1

, for more information.

ATTENTION: 

Do not remove or replace a Terminal Base unit while power is 

applied. Interruption of the backplane can result in unintentional operation or 
machine motion.

ATTENTION: 

If this equipment is used in a manner not specified by the manufacturer, 
the protection provided by the equipment may be impaired.

Read this document and the documents listed in the Additional Resources 
section about installation, configuration, and operation of this equipment 
before you install, configure, operate, or maintain this product. Users are 
required to familiarize themselves with installation and wiring instructions 
in addition to requirements of all applicable codes, laws, and standards.

Installation, adjustments, putting into service, use, assembly, disassembly, 
and maintenance are required to be carried out by suitably trained 
personnel in accordance with applicable code of practice.

In case of malfunction or damage, no attempts at repair should be made. 
The module should be returned to the manufacturer for repair. Do not 
dismantle the module.

This equipment is certified for use only within the surrounding air 
temperature range of 0…55 °C (32…131 °F). The equipment must not be 
used outside of this range.

Use only a soft dry anti-static cloth to wipe down equipment. Do not use 
any cleaning agents.

ATTENTION: 

 All wiring must comply with applicable electrical installation 

requirements (for example, N.E.C. article 501-4(b)).

Содержание 1794-PS13

Страница 1: ...nformation 2 Environment and Enclosure 3 Preventing Electrostatic Discharge 3 North American Hazardous Location Approval 5 Install Your Power Supply Module 7 Connect Wiring for your Power Supply Modul...

Страница 2: ...this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation Inc cannot assume responsibilit...

Страница 3: ...ad rating of 5VA or be approved for the application if nonmetallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain additi...

Страница 4: ...protection provided by the equipment may be impaired Read this document and the documents listed in the Additional Resources section about installation configuration and operation of this equipment be...

Страница 5: ...a is known to be nonhazardous Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous Secure any external connections that mate to this eq...

Страница 6: ...ystem with the 1794 PS13 power supply The 1794 PS3 power supply provides sufficient 24V DC power to operate 10 adapter modules You can use this 1794 PS3 power supply to operate an entire FLEX I O syst...

Страница 7: ...ewdriver or similar device to move the locking tab down while pressing the power supply module flush onto the DIN rail and release the locking tab to lock the power supply module in place If necessary...

Страница 8: ...120 230V AC power to the left side terminals on the connectors on the left side of the power supply module as follows 2 Connect terminal G 24V DC to the 24V DC terminal on the first adapter 3 Connect...

Страница 9: ...r Modules ATTENTION The total length of wire for terminals H I J and G must not exceed 3m 9 8ft Exceeding the 3m 9 8ft length can reduce noise immunity ATTENTION Input and output wiring must be in acc...

Страница 10: ...he power supply Output voltage exceeded 35V DC and overvoltage protection shut the unit down Output current is above 1 4A 1794 PS13 or above 3 2A 1794 PS3 Power 24V DC POWER SUPPLY 1794 PS13 24V COM P...

Страница 11: ...r ports North American temp code T3 Terminal screw torque 0 8 Nm 7 lbs in Input 1794 PS13 and 1794 PS3 Attribute 1794 PS13 1794 PS3 Nominal supply voltage 120V AC 50 60 Hz 0 6 A max 230V AC 50 60 Hz 0...

Страница 12: ...IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock 0 C Ta 55 C 32 F Ta 131 F Temperature surrounding air max 55 C 131 F Temperature nonoperating IEC 60068 2 1 Tes...

Страница 13: ...ous Locations certified for U S and Canada See UL File E334470 UL Listed Industrial Control Equipment certified for US and Canada See UL File E322657 CE European Union 2014 30 EU EMC Directive complia...

Страница 14: ...3 0 10 20 30 40 50 55 60 Max Output Current A Ambient Temperature oC The area within the curve represents the safe operating range for the module under various conditions of user supplied 24V DC suppl...

Страница 15: ...69D 35 1 4 A 59 2 3 A Mounting hole dimensions for optional mounting kit B B DIN rail 50 2 0 28 1 2 C C Secure DIN rail approximately every 200 mm Power 24V DC POWER SUPPLY 1794 PS13 24V COM Inches M...

Страница 16: ...returned follow these procedures Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form...

Отзывы: