Compact I/O End Caps/Terminators

Environment and Enclosure

Prevent Electrostatic Discharge

ATTENTION: 

This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage 
Category II applications (as defined in IEC publication 60664-1), at altitudes up to 2000 meters 
(6562 ft) without derating.

This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 
Publication 11. Without appropriate precautions, there may be potential difficulties ensuring 
electromagnetic compatibility in other environments due to conducted as well as radiated 
disturbance.

This equipment is supplied as open-type equipment. It must be mounted within an enclosure 
that is suitably designed for those specific environmental conditions that will be present and 
appropriately designed to prevent personal injury resulting from accessibility to live parts. The 
enclosure must have suitable flame-retardant properties to prevent or minimize the spread of 
flame, complying with a flame spread rating of 5VA, V2, V1, V0 (or equivalent) if non-metallic. 
The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of 
this publication may contain additional information regarding specific enclosure type ratings that 
are required to comply with certain product safety certifications.

In addition to this publication, see:

• Industrial Automation Wiring and Grounding Guidelines, for additional installation 

requirements, Allen-Bradley publication 

1770-4.1

.

• NEMA Standards publication 250 and IEC publication 60529, as applicable, for explanations of 

the degrees of protection provided by different types of enclosure.

ATTENTION: 

This equipment is sensitive to electrostatic discharge, which can cause internal 

damage and affect normal operation. Follow these guidelines when you handle this equipment:

• Touch a grounded object to discharge potential static.
• Wear an approved grounding wriststrap.
• Do not touch connectors or pins on component boards.
• Do not touch circuit components inside the equipment.
• Use a static-safe workstation, if available.
• Store the equipment in appropriate static-safe packaging when not in use.

Содержание 1769-ECL

Страница 1: ...re end caps A 1769 ECR right end cap a 1769 ECRK right end cap or a1769 ECL left end cap terminates the end of the communication bus Use this guide to install either end cap Topic Page Summary of Changes 2 1769 ECL Left End Cap 5 1769 ECL Dimensions 5 1769 ECR and 1769 ECRK Right End Cap 6 1769 ECR and 1769 ECRK Dimensions 7 Specifications 8 Environmental Specifications 8 Certifications 9 Addition...

Страница 2: ...Lorsque plusieurs produits sont combinés dans un système le code de température le plus défavorable code de température le plus faible peut être utilisé pour déterminer le code de température global du système Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l installation WARNING Explosion Hazard Do not disconnect equipmen...

Страница 3: ...s to prevent or minimize the spread of flame complying with a flame spread rating of 5VA V2 V1 V0 or equivalent if non metallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of thispublicationmaycontainadditionalinformationregardingspecificenclosuretyperatingsthat are required to comply with certain product safety certifications In addition to this ...

Страница 4: ...thedesignandconstructionofCategory3 equipment intended for use in potentially explosive atmospheres given in Annex II to this Directive Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 60079 15 and EN 60079 0 WARNING This equipment must be installed in an enclosure providing at least IP54 protection when applied in Zone 2 environments This equipme...

Страница 5: ...Rockwell Automation Publication 1769 IN015D EN P October 2017 5 Compact I O End Caps Terminators 1769 ECLLeftEndCap 1769 ECLDimensions 1 2 118 mm 4 6 in 15 mm 0 59 in 87 mm 3 43 in ...

Страница 6: ...6 Rockwell Automation Publication 1769 IN015D EN P October 2017 Compact I O End Caps Terminators 1769 ECRand1769 ECRKRightEndCap 1 2 3 ...

Страница 7: ...Rockwell Automation Publication 1769 IN015D EN P October 2017 7 Compact I O End Caps Terminators 1769 ECRand1769 ECRKDimensions 32 mm 1 26 in 18 mm 0 71 in 118 mm 4 65 in 85 mm 3 35 in ...

Страница 8: ...k 0 Ta 60 C 32 Ta 140 F Nonoperating temperature IEC 60068 2 1 Test Ab Unpackaged Nonoperating Cold IEC 60068 2 2 Test Bb Unpackaged Nonoperating Dry Heat IEC 60068 2 14 Test Na Unpackaged Nonoperating Thermal Shock 40 Ta 85 C 40 Ta 185 F Relative humidity 5 95 noncondensing Vibration IEC 60068 2 6 Test Fc Operating 5 g 10 500 Hz Operating shock IEC 60068 2 27 Test Ea Unpackaged Shock DIN rail mou...

Страница 9: ...0 CE European Union 2014 30 EU EMC Directive compliant with EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions C Tick Australian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emissions Ex European Union 2014 30 EU ATEX Directive compliant with EN 60079 15 Potentially Explosive Atmospheres Protection n II 3 G Ex nA IIC T4 X EN 60079 0 General Requirements Zone 2 ...

Страница 10: ...eeds better If you have any suggestions on how to improve this document complete the HowAre We Doing form at http literature rockwellautomation com idc groups literature documents du ra du002_ en e pdf Technical Support Center Knowledgebase Articles How toVideos FAQs Chat User Forums and Product Notification Updates https rockwellautomation custhelp com Local Technical Support Phone Numbers Locate...

Отзывы: