ControlLogix Power Supply

Environment and Enclosure

ATTENTION: 

This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in 

EN/IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating.

This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such 
environments.

This equipment is supplied as open-type equipment for indoor use. It must be mounted within an enclosure that is suitably designed for those specific 
environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The enclosure must 
have suitable flame-retardant properties to prevent or minimize the spread of flame, complying with a flame spread rating of 5VA or be approved for the 
application if nonmetallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain 
additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications.

In addition to this publication, see the following:

• Industrial Automation Wiring and Grounding Guidelines, publication 

1770-4.1

,

 

for additional installation requirements.

• NEMA Standard 250 and EN/IEC 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosures.

Prevent Electrostatic Discharge

ATTENTION: 

This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when 

you handle this equipment:

• Touch a grounded object to discharge potential static.
• Wear an approved grounding wriststrap.
• Do not touch connectors or pins on component boards.
• Do not touch circuit components inside the equipment.
• Use a static-safe workstation, if available.
• Store the equipment in appropriate static-safe packaging when not in use.

IMPORTANT

ControlLogix-XT system components are rated for extreme environmental conditions only when used properly with other Logix-XT system 
components. The use of ControlLogix-XT components with standard ControlLogix system components nullifies extreme-environment 
ratings.

If a ControlLogix-XT module is used with standard ControlLogix products, the ControlLogix-XT module can withstand only the environments specified for the 
standard ControlLogix version of the module. For example, if a 1756-L63XT controller is used in a standard 1756-A10 chassis, the ControlLogix-XT controller 
can withstand only the environment specified for the standard 1756-L63 controller.

The ControlLogix-XT system components are designed to meet the same and greater operational and environmental requirements as traditional 
ControlLogix products.

When a ControlLogix-XT component is used as a replacement for a traditional ControlLogix component, the functional and environmental requirements of 
the traditional ControlLogix component apply, with the exception of the power output ratings.

Содержание 1756-PA30XT

Страница 1: ...he power supply that you can use This table lists the chassis that can be installed with each power supply Topic Page Summary of Changes 5 Tools Required 6 Install the Power Supply 6 Connect the Power...

Страница 2: ...ti nella sezione Altre risorse riguardanti l installazione la configurazione ed il funzionamento dell apparecchiatura Gli utenti devono leggere e comprendere le istruzioni di installazione e cablaggio...

Страница 3: ...plicable for explanations of the degrees of protection provided by different types of enclosures Prevent Electrostatic Discharge ATTENTION Thisequipmentissensitivetoelectrostaticdischarge whichcancaus...

Страница 4: ...ctions that mate to this equipment by using screws sliding latches threaded connectors or other means provided with this product Substitution of components may impair suitability for Class I Division...

Страница 5: ...1325026X IECEx UL 14 0008X 1756 PC75 None 1756 PH75 1756 PH75K None 1756 PAXT None 1756 PBXT Ex nA IICT4 Gc DEMKO13ATEX1325026X IECEx UL 14 0008X 1756 PA30XT None 1756 PB30XT Ex nA IICT4 Gc DEMKO13ATE...

Страница 6: ...flush with the front of the chassis 4 Tighten the top and bottom screws to fasten the power supply to the chassis 3 18 mm 0 125 in slotted screwdriver Crimper 6 35 mm 0 25 in slotted or 2 Phillips scr...

Страница 7: ...ing ATTENTION Do not wire more than one conductor on any single terminal Use 15 A time delay type fuse in all ungrounded power connections IMPORTANT The voltage input connections of the power supplies...

Страница 8: ...groove at the front of the power supply 2 Feed a cable tie through the retainer on the v groove 3 To secure the power cable tighten the cable tie 4 Trim any excess cable tie length as appropriate Rem...

Страница 9: ...e power 3 Loosen the screws that secure the power supply to the chassis See step 4 on page 6 for the location of the screws on the power supply 4 Slide the power supply out so that the rear connector...

Страница 10: ...ure type rating None open style Torque 0 565 N m 5 lb in Dimensions HxWxD approx 14 0 x 11 2 x 14 5 cm 5 51 x 4 41 x 5 71 in Wire size 2 5 mm2 14 AWG solid or stranded copper wire rated at 90 C 194 F...

Страница 11: ...13 F Ta 158 F Temperature surrounding air max 70 C 158 F Enclosure type rating None open style Torque 0 565 N m 5 lb in Dimensions HxWxD approx 14 0 x 11 2 x 14 5 cm 5 51 x 4 41 x 5 71 in 14 0 x 7 8 x...

Страница 12: ...ion needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at http literature rockwellautomation com idc groups literature documents du ra du002_ e...

Отзывы: