Rockwell Automation Publication 1756-PM004D-EN-P - September 2012
75
Data Access Control
Chapter
4
Parameters/Local Tab
Properties
No change is applied to the External Access box if you switch the usage among Input
parameter, Output parameter or Local tag, except when the usage is a Local tag, the
box is disabled.
If you change the usage from InOut parameter to:
•
Input or output parameter - the External Access box is enabled and your last
selection for creating an equipment phase/Add-On Instruction input parameter or
an equipment phase/Add-On Instruction output parameter is displayed
accordingly.
•
Local tag - the External Access is updated to None and the box is disabled.
The External Access box also is disabled if:
•
you do not have permission to change external access settings.
(1)
•
the controller is online.
•
the tag is an alias tag.
•
the Add-On Instruction is in Source Protection mode.
Add-On Instruction Definition
- Parameters Tab
The External Access column is disabled if:
•
InOut parameters, which are blank.
•
EnableIn and EnableOut parameters, which default Read Only.
•
you do not have permission to change the external access settings.
•
the controller is online.
•
the tag is an alias tag.
•
the Add-On Instruction is in Source Protection mode.
•
the row represents an expanded bit, or data member.
When creating a new parameter, changing usage causes the External Access column
auto update to default to:
•
Input parameter - equipment phase input parameter and Add-On Instruction
input parameter.
•
Output parameter - equipment phase output parameter and Add-On Instruction
output parameter.
•
InOut parameter - External Access column cell is blank and disabled.
Changing external access attributes will cause:
•
an error message if you change a tag from Input or Output parameter to InOut
parameter and the present attribute is either Read/Write, or Read Only.
•
no change if you switch between Input and Output parameters.
•
the value of the external access updates to the new target for an alias.
Add-On Instruction Definition
- Local Tags Tab
The External Access column is disabled if:
•
you do not have permission to change external access settings.
•
the controller is online.
•
the Add-On Instruction is in Source Protection mode.
•
the row represents an expanded array dimension, bit, or data member.
Add-On Instruction Edit Tags
Note: External access is not applicable for InOut parameters because they are just
references until invoked.
The External Access column is disabled if:
•
EnableIn and EnableOut parameters, which
default ‘Read Only’.
•
you do not have permission to change the external access settings.
•
the controller is online.
•
the tag is an alias tag.
•
the Add-On Instruction is in Source Protection mode.
•
the row represents an expanded array dimension, bit, or data member.
When creating a new parameter, changing usage causes the External Access column
auto update to default to:
•
Input parameter - equipment phase input parameter and Add-On Instruction
input parameter.
•
Output parameter - equipment phase output parameter and Add-On Instruction
output parameter.
•
InOut parameter - External Access column cell is blank and disabled.
•
Local tag - external access is updated to None. Changing external access attributes
will cause:
•
a warning message if you change a tag from Input or Output parameter to InOut
parameter and the present attribute is either Read/Write, or Read Only.
•
no change if you switch between Input, Output parameters and Local tag
•
the value of the external access updates to the new target for an alias.
(1)
If you have Add-On Instruction Modify permission, you also can modify external access of an Add-On Instruction tag.
Dialog Box/Window
Considerations
Содержание 1756-L65 ControlLogix 5565
Страница 4: ...2 Rockwell Automation Publication 1756 PM004D EN P September 2012 Summary of Changes Notes...
Страница 8: ...6 Rockwell Automation Publication 1756 PM004D EN P September 2012 Preface Notes...
Страница 66: ...64 Rockwell Automation Publication 1756 PM004D EN P September 2012 Chapter 3 Force I O Notes...
Страница 88: ...86 Rockwell Automation Publication 1756 PM004D EN P September 2012 Index...
Страница 89: ......