Products marked “CL I, DIV 2, GP A, B, C, D” are 
suitable for use in Class I Division 2 Groups A, B, C, 
D, Hazardous Locations and nonhazardous locations 
only. Each product is supplied with markings on the 
rating nameplate indicating the hazardous location 
temperature code. When combining products within 
a system, the most adverse temperature code (lowest 
“T” number) may be used to help determine the 
overall temperature code of the system. 
Combinations of equipment in your system are 
subject to investigation by the local Authority Having 
Jurisdiction at the time of installation.

Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne 
conviennent qu’à une utilisation en environnements 
de Classe I Division 2 Groupes A, B, C, D dangereux 
et non dangereux. Chaque produit est livré avec des 
marquages sur sa plaque d’identification qui 
indiquent le code de température pour les 
environnements dangereux. Lorsque plusieurs 
produits sont combinés dans un système, le code de 
température le plus défavorable (code de 
température le plus faible) peut être utilisé pour 
déterminer le code de température global du 
système. Les combinaisons d’équipements dans le 
système sont sujettes à inspection par les autorités 
locales qualifiées au moment de l’installation.

WARNING

!

EXPLOSION HAZARD

Do not disconnect 
equipment unless 
power has been 
removed or the area is 
known to be 
nonhazardous. 

Do not disconnect 
connections to this 
equipment unless 
power has been 
removed or the area is 
known to be 
nonhazardous. Secure 
any external 
connections that mate 
to this equipment by 
using screws, sliding 
latches, threaded 
connectors, or other 
means provided with 
this product.

Substitution of 
components may impair 
suitability for Class I, 
Division 2.

If this product contains 
batteries, they must 
only be changed in an 
area known to be 
nonhazardous.

AVERTISSEMENT

!

RISQUE D’EXPLOSION

Couper le courant ou 
s’assurer que 
l’environnement est 
classé non dangereux 
avant de débrancher 
l'équipement.

Couper le courant ou 
s'assurer que 
l’environnement est 
classé non dangereux 
avant de débrancher les 
connecteurs. Fixer tous 
les connecteurs 
externes reliés à cet 
équipement à l'aide de 
vis, loquets coulissants, 
connecteurs filetés ou 
autres moyens fournis 
avec ce produit.

La substitution de 
composants peut rendre 
cet équipement 
inadapté à une 
utilisation en 
environnement de 
Classe I, Division 2.

S’assurer que 
l’environnement est 
classé non dangereux 
avant de changer les 
piles.

Содержание 1746-BTM

Страница 1: ...re the 1746 BTM barrel temperature control module For this information See page Important User Information 2 Prevent Electrostatic Discharge 3 How to Get the Related User Manual 4 Determine the Module...

Страница 2: ...publication SGI 1 1 Safety Guidelines for the Application Installation and Maintenance of Solid State Control available from your local Rockwell Automation office describes some important differences...

Страница 3: ...e enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to compl...

Страница 4: ...ple type applications require an industrial enclosure to reduce the effects of electrical interference Thermocouple inputs are highly susceptible to electrical noises due to the small signal amplitude...

Страница 5: ...dule into the chassis until both top and bottom retaining clips are secured Apply firm even pressure on the module to attach it to its backplane connector Never force the module into the slot 4 Cover...

Страница 6: ...re Control Module Publication 1746 IN020B EN P July 2002 5 To remove press the releases at the top and bottom of the module and slide the module out of the chassis slot card guides topandbottom releas...

Страница 7: ...RTB 2 Grasp the RTB at the top and bottom and pull outward and down When removing the RTB be careful not to damage the CJC sensors 3 Use the write on label to identify the slot chassis and module typ...

Страница 8: ...he RTB retaining screws with the mating connector on the module Be careful not to damage the CJC sensors 5 Press the RTB firmly onto the connector contacts 6 Alternately tighten the two retaining scre...

Страница 9: ...JC A or CJC B as shown below ATTENTION Do not remove or loosen the cold junction compensating thermistors located on the terminal block Both thermistors are critical to ensure accurate thermocouple in...

Страница 10: ...or contact your sensor manufacturer for additional details When trimming cable leads minimize the length of unshielded wires Ground the shield drain wire at only one end of the cable The preferred lo...

Страница 11: ...the wires 3 At the module end of the cables extract the drain wire and signal wires remove the foil shield bundle the input cables with a cable strap 4 Connect drain wires together and solder them to...

Страница 12: ...ng the leads short IMPORTANT If noise persists try grounding the opposite end of the cable Ground one end only Wires 3 8 Make unshielded wires as short as possible Limit braid length to 12 or less Sol...

Страница 13: ...code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature global du syst me Les combinaisons d quipements dans le syst me sont sujettes inspection par les autorit s loc...

Страница 14: ...IEC 60068 2 2 Test Bc Un packaged Non operating Dry Heat IEC 60068 2 14 Test Na Un packaged Non operating Thermal Shock 40 to 85o C 40 to 185o F Relative Humidity IEC 60068 2 30 Test Db Un packaged No...

Страница 15: ...Barrel Temperature Control Module 15 Publication 1746 IN020B EN P July 2002 Notes...

Страница 16: ...urs of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your product up and running New Pro...

Отзывы: